Clinical validation and experiences of the microfluidics sperm selection device ZyMōt™ for standard IVF.

IF 1.8 Q3 OBSTETRICS & GYNECOLOGY Jornal Brasileiro de Reproducao Assistida Pub Date : 2024-12-26 DOI:10.5935/1518-0557.20240104
Emma Adolfsson, Johanna Ingberg, Emma Igersten, Therese Bohlin
{"title":"Clinical validation and experiences of the microfluidics sperm selection device ZyMōt™ for standard IVF.","authors":"Emma Adolfsson, Johanna Ingberg, Emma Igersten, Therese Bohlin","doi":"10.5935/1518-0557.20240104","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Clinical validation of sperm selection device ZyMōt™ for standard IVF.</p><p><strong>Methods: </strong>The pre-clinical validation of ZyMōt™ included several steps. First, split semen preparation compared density gradient centrifugation (DGC) to ZyMōt™ with primary outcome fraction and absolute number of progressive motile sperm. Second, sibling oocytes were fertilized with sperms prepared with DGC and sperms selected by ZyMōt™, primary endpoint fertilization rate, utility rate, embryo development pace quality. After this, DGC was replaced by ZyMōt™, first without centrifugation steps, and then with a five-minute centrifugation step and subsequent media change prior to gamete co-incubation. Endpoint was assessment of key performance indicators against previous results using DGC for standard IVF.</p><p><strong>Results: </strong>ZyMōt™ resulted in purer sperm selection compared to DGC (fraction progressive motile sperm 97.2±3.1% vs. 83.0±14.1%, p<0.01). Fertilization of sibling oocytes resulted in similar fertilization rates and utility rates, and no differences in embryo development pace or quality. However, after changing sperm selection protocol from DGC to ZyMōt™ for standard IVF for all fresh semen samples with motile sperm, the fertilization rates and utility rates were significantly reduced, and cases of total failure of fertilization increased substantially. Adding five-minute centrifugation and media change after centrifugation to the sperm selection protocol restored fertilization rate, including total failure of fertilization rate, to normal.</p><p><strong>Conclusions: </strong>To conclude, the ZyMōt™ sperm selection device is suitable for standard IVF only after inclusion of five minutes centrifugation and subsequent media change prior to gamete co-incubation.</p>","PeriodicalId":46364,"journal":{"name":"Jornal Brasileiro de Reproducao Assistida","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jornal Brasileiro de Reproducao Assistida","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/1518-0557.20240104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Clinical validation of sperm selection device ZyMōt™ for standard IVF.

Methods: The pre-clinical validation of ZyMōt™ included several steps. First, split semen preparation compared density gradient centrifugation (DGC) to ZyMōt™ with primary outcome fraction and absolute number of progressive motile sperm. Second, sibling oocytes were fertilized with sperms prepared with DGC and sperms selected by ZyMōt™, primary endpoint fertilization rate, utility rate, embryo development pace quality. After this, DGC was replaced by ZyMōt™, first without centrifugation steps, and then with a five-minute centrifugation step and subsequent media change prior to gamete co-incubation. Endpoint was assessment of key performance indicators against previous results using DGC for standard IVF.

Results: ZyMōt™ resulted in purer sperm selection compared to DGC (fraction progressive motile sperm 97.2±3.1% vs. 83.0±14.1%, p<0.01). Fertilization of sibling oocytes resulted in similar fertilization rates and utility rates, and no differences in embryo development pace or quality. However, after changing sperm selection protocol from DGC to ZyMōt™ for standard IVF for all fresh semen samples with motile sperm, the fertilization rates and utility rates were significantly reduced, and cases of total failure of fertilization increased substantially. Adding five-minute centrifugation and media change after centrifugation to the sperm selection protocol restored fertilization rate, including total failure of fertilization rate, to normal.

Conclusions: To conclude, the ZyMōt™ sperm selection device is suitable for standard IVF only after inclusion of five minutes centrifugation and subsequent media change prior to gamete co-incubation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.30
自引率
6.70%
发文量
56
期刊最新文献
Embryo Cryopreservation: What do couples think about it? Advanced 3Dimentional engineered microenvironment to improve of in vitro spermatogenesis: narrative review. Do LGTB people desire to have children? A Brazilian cross-sectional survey. Effect of hydro-ethanol extract of Caesalpinia pulcherrima (L.) Sw. leaves in human and rat: In vitro approach of male contraceptive development. Impact of Infertility and Medically Assisted Reproduction Treatments on Female Sexuality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1