Optimal Cerebral Protection Confirmed by Transcranial Doppler During Transcarotid Artery Revascularization.

Q2 Medicine Methodist DeBakey cardiovascular journal Pub Date : 2024-12-26 eCollection Date: 2024-01-01 DOI:10.14797/mdcvj.1465
Reka Vernes, Adam Bardoczi, Alan B Lumsden, Zsolt F Garami
{"title":"Optimal Cerebral Protection Confirmed by Transcranial Doppler During Transcarotid Artery Revascularization.","authors":"Reka Vernes, Adam Bardoczi, Alan B Lumsden, Zsolt F Garami","doi":"10.14797/mdcvj.1465","DOIUrl":null,"url":null,"abstract":"<p><p>Transcarotid artery revascularization (TCAR) is a novel method to treat severe stenosis of the carotid artery with minimal embolization. During TCAR, flow reversal system redirects blood from the internal, external, and common carotid arteries into the femoral vein through a filter system to prevent debris and microparticles from entering the cerebral circulation. Transcranial Doppler (TCD) monitoring allows real-time detection of blood flow in the cerebral arteries during the operation and informs the surgeon of flow changes or possible emboli. With this information, the steps and maneuvers during the procedure and the function of the flow reversal system can be further improved to avoid stroke or other neurological complications. In this case study, we present a TCAR procedure with TCD monitoring in an asymptomatic male patient exhibiting severe left-sided internal carotid artery stenosis. Optimal cerebral protection was achieved due to the neuroprotective flow reversal system of TCAR.</p>","PeriodicalId":39207,"journal":{"name":"Methodist DeBakey cardiovascular journal","volume":"20 1","pages":"106-112"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11673467/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methodist DeBakey cardiovascular journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14797/mdcvj.1465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Transcarotid artery revascularization (TCAR) is a novel method to treat severe stenosis of the carotid artery with minimal embolization. During TCAR, flow reversal system redirects blood from the internal, external, and common carotid arteries into the femoral vein through a filter system to prevent debris and microparticles from entering the cerebral circulation. Transcranial Doppler (TCD) monitoring allows real-time detection of blood flow in the cerebral arteries during the operation and informs the surgeon of flow changes or possible emboli. With this information, the steps and maneuvers during the procedure and the function of the flow reversal system can be further improved to avoid stroke or other neurological complications. In this case study, we present a TCAR procedure with TCD monitoring in an asymptomatic male patient exhibiting severe left-sided internal carotid artery stenosis. Optimal cerebral protection was achieved due to the neuroprotective flow reversal system of TCAR.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经颅多普勒证实经颈动脉血运重建术中的最佳脑保护。
经颈动脉重建术(TCAR)是一种以最小栓塞治疗颈动脉严重狭窄的新方法。在TCAR中,血流逆转系统通过过滤系统将血液从颈内动脉、颈外动脉和颈总动脉重定向到股静脉,以防止碎片和微粒进入脑循环。经颅多普勒(TCD)监测可以实时检测手术期间脑动脉的血流,并通知外科医生血流变化或可能的栓塞。有了这些信息,手术过程中的步骤和操作以及血流逆转系统的功能可以进一步改进,以避免中风或其他神经系统并发症。在这个病例研究中,我们提出了TCAR手术与TCD监测在无症状的男性患者表现出严重的左侧颈内动脉狭窄。由于TCAR的神经保护性血流逆转系统,实现了最佳的脑保护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
65
期刊最新文献
Heart of Stone: Rare Case of Incidentally Detected Endocardial Calcification. The Exposome and Cardiovascular Health: Webcast December 12 2024. Cardiac Recovery: Webcast September 24 2024. Congenital Fibrolipoma with Hamartomatous Changes of the Internal Jugular Vein: First Published Case Report. Optimal Cerebral Protection Confirmed by Transcranial Doppler During Transcarotid Artery Revascularization.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1