Diaphragm Ultrasonography in Patients Without Symptoms or Signs of Respiratory Impairment.

IF 3.1 3区 医学 Q2 CLINICAL NEUROLOGY Muscle & Nerve Pub Date : 2025-03-01 Epub Date: 2024-12-31 DOI:10.1002/mus.28331
Martina Gorenc, Rok Blagus, Friderika Kresal, Gregor Omejec
{"title":"Diaphragm Ultrasonography in Patients Without Symptoms or Signs of Respiratory Impairment.","authors":"Martina Gorenc, Rok Blagus, Friderika Kresal, Gregor Omejec","doi":"10.1002/mus.28331","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction/aims: </strong>We aimed to determine differences in diaphragm thickness by including/excluding pleural and peritoneal membranes, the variability in diaphragm thickness over the apposition zone, and the predictors of diaphragm thickness and excursion measurements.</p><p><strong>Methods: </strong>At least 10 male and female subjects were recruited for each decade of life. Spirometry, respiratory muscle strength, and the diaphragm ultrasound (US) measurements were performed. Multivariate linear regression was applied to determine associations between diaphragm US parameters, subject characteristics, spirometry, and respiratory muscle strength.</p><p><strong>Results: </strong>In 156 subjects (mean 47.8 ± 17.7; 20-80 years of age), a significant difference in diaphragm thickness was found when comparing measurements that included and excluded the pleural and peritoneal membranes (mean 2.3 vs. 1.7 mm; average difference of 35% (95% CI [15.3-60]); p < 0.001), as well as the minimum and maximum diaphragm thicknesses at different locations over the apposition zone (mean 1.4 vs. 2.1 mm; p < 0.001). Adjusting for sex, age, height, sniff nasal inspiratory pressure, and forced vital capacity, a positive association was found between body mass index (BMI) and diaphragm thickness (β =0.024, p < 0.001, partial R <sup>2</sup> = 0.31, 95% CI [0.018, 0.030]); a negative association was found with the thickening ratio (β = -0.013, p = 0.050, partial R <sup>2</sup> = 0.04, 95% CI [-0.024, -0.002]).</p><p><strong>Discussion: </strong>Caliper placement and the location of measurement over the apposition zone greatly affect diaphragm thickness, which is also associated with BMI. Therefore, a standardized protocol for measuring diaphragmatic thickness and excursion is desirable, and BMI should be considered when interpreting the results.</p>","PeriodicalId":18968,"journal":{"name":"Muscle & Nerve","volume":" ","pages":"406-413"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Muscle & Nerve","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mus.28331","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction/aims: We aimed to determine differences in diaphragm thickness by including/excluding pleural and peritoneal membranes, the variability in diaphragm thickness over the apposition zone, and the predictors of diaphragm thickness and excursion measurements.

Methods: At least 10 male and female subjects were recruited for each decade of life. Spirometry, respiratory muscle strength, and the diaphragm ultrasound (US) measurements were performed. Multivariate linear regression was applied to determine associations between diaphragm US parameters, subject characteristics, spirometry, and respiratory muscle strength.

Results: In 156 subjects (mean 47.8 ± 17.7; 20-80 years of age), a significant difference in diaphragm thickness was found when comparing measurements that included and excluded the pleural and peritoneal membranes (mean 2.3 vs. 1.7 mm; average difference of 35% (95% CI [15.3-60]); p < 0.001), as well as the minimum and maximum diaphragm thicknesses at different locations over the apposition zone (mean 1.4 vs. 2.1 mm; p < 0.001). Adjusting for sex, age, height, sniff nasal inspiratory pressure, and forced vital capacity, a positive association was found between body mass index (BMI) and diaphragm thickness (β =0.024, p < 0.001, partial R 2 = 0.31, 95% CI [0.018, 0.030]); a negative association was found with the thickening ratio (β = -0.013, p = 0.050, partial R 2 = 0.04, 95% CI [-0.024, -0.002]).

Discussion: Caliper placement and the location of measurement over the apposition zone greatly affect diaphragm thickness, which is also associated with BMI. Therefore, a standardized protocol for measuring diaphragmatic thickness and excursion is desirable, and BMI should be considered when interpreting the results.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无呼吸障碍症状或体征患者的膈超声检查。
前言/目的:我们的目的是通过包括/不包括胸膜和腹膜来确定膈膜厚度的差异,膈膜厚度在傍位区的变异性,以及膈膜厚度和偏移测量的预测因子。方法:每十年至少招募10名男性和女性受试者。进行肺活量测定、呼吸肌力量和膈肌超声(US)测量。应用多元线性回归来确定横膈膜US参数、受试者特征、肺活量测定和呼吸肌力量之间的关系。结果:156例受试者(平均47.8±17.7;20-80岁),当比较包括和不包括胸膜和腹膜的测量值时,发现膈膜厚度有显著差异(平均2.3 vs 1.7 mm;平均差异为35% (95% CI [15.3-60]);p 2 = 0.31, 95% CI [0.018, 0.030]);与增厚率呈负相关(β = -0.013, p = 0.050,部分R2 = 0.04, 95% CI[-0.024, -0.002])。讨论:卡钳的位置和测量位置在相对区域上对隔膜厚度有很大影响,这也与BMI有关。因此,测量横膈膜厚度和偏移的标准化方案是可取的,在解释结果时应考虑BMI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Muscle & Nerve
Muscle & Nerve 医学-临床神经学
CiteScore
6.40
自引率
5.90%
发文量
287
审稿时长
3-6 weeks
期刊介绍: Muscle & Nerve is an international and interdisciplinary publication of original contributions, in both health and disease, concerning studies of the muscle, the neuromuscular junction, the peripheral motor, sensory and autonomic neurons, and the central nervous system where the behavior of the peripheral nervous system is clarified. Appearing monthly, Muscle & Nerve publishes clinical studies and clinically relevant research reports in the fields of anatomy, biochemistry, cell biology, electrophysiology and electrodiagnosis, epidemiology, genetics, immunology, pathology, pharmacology, physiology, toxicology, and virology. The Journal welcomes articles and reports on basic clinical electrophysiology and electrodiagnosis. We expedite some papers dealing with timely topics to keep up with the fast-moving pace of science, based on the referees'' recommendation.
期刊最新文献
AANEM News & Insights. Sural/Radial Amplitude Ratio: A Useful Tool to Diagnose Non-Length-Dependent Neuropathy. Correction to "Characteristics of After-Discharges Following Compound Muscle Action Potential or F-Wave in Primary Peripheral Nerve Hyperexcitability Syndrome". Survival Outcomes of Medicare-Covered Elderly US Population With Myasthenia Gravis. Physiology of Abnormal Muscle Fiber Generators.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1