Comparison of the performance of myopia control in European children and adolescents with defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL) spectacles.

IF 2 4区 医学 Q2 PEDIATRICS BMJ Paediatrics Open Pub Date : 2024-12-31 DOI:10.1136/bmjpo-2024-003187
Andrea Lembo, Irene Schiavetti, Massimiliano Serafino, Roberto Caputo, Paolo Nucci
{"title":"Comparison of the performance of myopia control in European children and adolescents with defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL) spectacles.","authors":"Andrea Lembo, Irene Schiavetti, Massimiliano Serafino, Roberto Caputo, Paolo Nucci","doi":"10.1136/bmjpo-2024-003187","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A performance comparison of two myopia control spectacle lens designs, defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL), at slowing myopia progression in a European child/adolescent population. Previous research directly comparing these designs has been limited to Chinese participants and 1-year follow-up. The prevalence of myopia in European child/adolescent has been estimated at 22.60%.</p><p><strong>Methods: </strong>Retrospective cohort study of individuals (6-17 years) with myopia progression. Participants wore DIMS (Hoya MiyoSmart) or HAL (Essilor Stellest) spectacles for a minimum of 2 years. Axial length (AL) and cycloplegic autorefraction (spherical equivalent refraction (SER)) were measured at baseline and 1 and 2 years.</p><p><strong>Results: </strong>Mean 1-year SER changes for DIMS were -0.34D (±0.46 SD) and HAL -0.30D (±0.30); 2-year changes for DIMS were -0.50D (±0.64 SD) and HAL -0.63D (±0.56). Mean 1-year AL increases for DIMS were 0.19 mm (±0.56) and HAL 0.15 mm (±0.47); 2-year increases for DIMS were 0.29 mm (±0.63) and HAL 0.32 mm (±0.72). For equivalence margins of 0.25D and 0.50D for SER at 1 and 2 years, respectively, and similarly 0.20 mm and 0.30 mm margins for AL, DIMS and HAL lenses were equivalent apart from AL at 1 year where the 0.21 mm 95% CI upper limit just exceeded 0.20 mm. At both 1 and 2 years, none of the differences in mean SERs or ALs between DIMS and HAL were clinically or statistically significant (p≥0.05 Mann-Whitney U test). Using linear mixed model analysis, the interaction between lens type and time did not significantly affect SER or AL at 1- or 2-year follow-up (p≥0.05). 38.4% of children/adolescents with DIMS had no SER progression at 2 years, compared with 21.9% with HAL (p=0.047).</p><p><strong>Conclusion: </strong>In a European population, DIMS and HAL lenses are essentially equivalent in their ability to reduce myopia progression and AL elongation over a 2-year follow-up period.</p>","PeriodicalId":9069,"journal":{"name":"BMJ Paediatrics Open","volume":"8 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11749801/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Paediatrics Open","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bmjpo-2024-003187","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: A performance comparison of two myopia control spectacle lens designs, defocus incorporated multiple segments (DIMS) and highly aspherical lenslets (HAL), at slowing myopia progression in a European child/adolescent population. Previous research directly comparing these designs has been limited to Chinese participants and 1-year follow-up. The prevalence of myopia in European child/adolescent has been estimated at 22.60%.

Methods: Retrospective cohort study of individuals (6-17 years) with myopia progression. Participants wore DIMS (Hoya MiyoSmart) or HAL (Essilor Stellest) spectacles for a minimum of 2 years. Axial length (AL) and cycloplegic autorefraction (spherical equivalent refraction (SER)) were measured at baseline and 1 and 2 years.

Results: Mean 1-year SER changes for DIMS were -0.34D (±0.46 SD) and HAL -0.30D (±0.30); 2-year changes for DIMS were -0.50D (±0.64 SD) and HAL -0.63D (±0.56). Mean 1-year AL increases for DIMS were 0.19 mm (±0.56) and HAL 0.15 mm (±0.47); 2-year increases for DIMS were 0.29 mm (±0.63) and HAL 0.32 mm (±0.72). For equivalence margins of 0.25D and 0.50D for SER at 1 and 2 years, respectively, and similarly 0.20 mm and 0.30 mm margins for AL, DIMS and HAL lenses were equivalent apart from AL at 1 year where the 0.21 mm 95% CI upper limit just exceeded 0.20 mm. At both 1 and 2 years, none of the differences in mean SERs or ALs between DIMS and HAL were clinically or statistically significant (p≥0.05 Mann-Whitney U test). Using linear mixed model analysis, the interaction between lens type and time did not significantly affect SER or AL at 1- or 2-year follow-up (p≥0.05). 38.4% of children/adolescents with DIMS had no SER progression at 2 years, compared with 21.9% with HAL (p=0.047).

Conclusion: In a European population, DIMS and HAL lenses are essentially equivalent in their ability to reduce myopia progression and AL elongation over a 2-year follow-up period.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
欧洲儿童和青少年离焦合并多段(DIMS)和高度非球面透镜(HAL)眼镜近视控制效果的比较
目的:比较两种控制近视的镜片设计,离焦合并多段(DIMS)和高度非球面镜片(HAL),在减缓欧洲儿童/青少年近视进展方面的性能。先前直接比较这些设计的研究仅限于中国参与者和1年的随访。欧洲儿童/青少年的近视患病率估计为22.60%。方法:回顾性队列研究近视进展个体(6-17岁)。参与者佩戴DIMS (Hoya MiyoSmart)或HAL (Essilor Stellest)眼镜至少2年。在基线和1年和2年测量轴长(AL)和睫状体麻痹自折射(球等效折射(SER))。结果:DIMS患者1年平均SER变化为-0.34D(±0.46 SD), HAL为-0.30D(±0.30);2年DIMS变化为-0.50D(±0.64 SD), HAL变化为-0.63 3d(±0.56)。DIMS患者1年平均AL升高0.19 mm(±0.56),HAL患者平均AL升高0.15 mm(±0.47);2年DIMS增加0.29 mm(±0.63),HAL增加0.32 mm(±0.72)。对于1年和2年SER的等效边缘分别为0.25D和0.50D, AL的等效边缘同样为0.20 mm和0.30 mm,除了AL, DIMS和HAL透镜在1年的等效边缘是相等的,其中0.21 mm 95% CI上限刚刚超过0.20 mm。在1年和2年,DIMS和HAL的平均SERs或ALs均无临床或统计学差异(p≥0.05 Mann-Whitney U检验)。采用线性混合模型分析,1年或2年随访时,晶状体类型和时间的相互作用对SER或AL无显著影响(p≥0.05)。38.4%患有DIMS的儿童/青少年在2年时没有SER进展,而患有HAL的儿童/青少年为21.9% (p=0.047)。结论:在欧洲人群中,在2年的随访期内,DIMS和HAL镜片在减少近视进展和AL伸长方面的能力基本相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Paediatrics Open
BMJ Paediatrics Open Medicine-Pediatrics, Perinatology and Child Health
CiteScore
4.10
自引率
3.80%
发文量
124
期刊最新文献
Dexmedetomidine in neonates: utilisation trends and safety profile over time in a neonatal intensive care unit. Exploring the current usage of and attitudes towards transanastomotic tube (TAT) feeding in infants born with duodenal atresia: a survey of practice in the UK. The impact of climate change on child nutrition in Indonesia: a conceptual framework and scoping review of the available evidence. Feasibility and acceptability of the Alarm Distress Baby Scale (ADBB) in universal health visiting practice in England: a mixed-methods study using Normalisation Process Theory. Comparing different administration methods of subanaesthetic propofol to mitigate emergence agitation in preschool children undergoing day surgery: a double-blind, randomised controlled study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1