Identifying Factors that Influence Pediatric Echo Lab Image Quality: Development and Validation of a New Assessment Tool.

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pediatric Cardiology Pub Date : 2024-12-31 DOI:10.1007/s00246-024-03763-8
Garick D Hill, Eunice Hahn, Joseph R Block, Alicia H Chaves, Kristopher Cumbermack, Joan Lipinski, Shobha Natarajan, David A Parra, Joshua D Robinson, Brian D Soriano, Michael J Walsh, JangDong Seo, Peter Frommelt
{"title":"Identifying Factors that Influence Pediatric Echo Lab Image Quality: Development and Validation of a New Assessment Tool.","authors":"Garick D Hill, Eunice Hahn, Joseph R Block, Alicia H Chaves, Kristopher Cumbermack, Joan Lipinski, Shobha Natarajan, David A Parra, Joshua D Robinson, Brian D Soriano, Michael J Walsh, JangDong Seo, Peter Frommelt","doi":"10.1007/s00246-024-03763-8","DOIUrl":null,"url":null,"abstract":"<p><p>No method of evaluating transthoracic echocardiograms (TTE) image quality (IQ) has been validated. Furthermore, structural echo lab elements impacting IQ are unknown. We sought to develop and validate a TTE IQ grading tool and determine patient and echo lab features associated with IQ. Ten pediatric echo labs each submitted 50 consecutive new patient TTEs without complex heart disease. For each study, 3 sonographers independently rated IQ and performed routine measurements. IQ scoring used the American College of Cardiology Quality Network (ACC QNet) tool plus a novel Likert scale component. IQ scores were validated against the ability to make measurements and, when all measurements were made, variation between sonographers. After validation, patient and lab factors, from a previously published survey, associated with improved TTE IQ were determined by linear regression. Total IQ score (R<sup>2</sup> = 0.64), ACC QNet (R<sup>2</sup> = 0.29) and the Likert component (R<sup>2</sup> = 0.52) correlated with the total number of measurements made (p < 0.001). For the 236 (52%) TTEs with all measurements, the Likert scale component (OR 0.9, 95% CI 0.82-0.99, p = 0.037) was associated with lower measurement variability. Factors significantly associated with worse IQ scores were higher patient weight, performance by a traveling sonographer, lower annual and inpatient TTE volume, less dedicated teaching/administrative sonographer time, and full-day sessions for reading physicians. A novel TTE IQ scoring tool was created and validated for pediatric TTE. Modifiable structural components of echo labs associated with TTE IQ were identified. This novel IQ tool should guide IQ beyond the ACC QNet score.</p>","PeriodicalId":19814,"journal":{"name":"Pediatric Cardiology","volume":" ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00246-024-03763-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

No method of evaluating transthoracic echocardiograms (TTE) image quality (IQ) has been validated. Furthermore, structural echo lab elements impacting IQ are unknown. We sought to develop and validate a TTE IQ grading tool and determine patient and echo lab features associated with IQ. Ten pediatric echo labs each submitted 50 consecutive new patient TTEs without complex heart disease. For each study, 3 sonographers independently rated IQ and performed routine measurements. IQ scoring used the American College of Cardiology Quality Network (ACC QNet) tool plus a novel Likert scale component. IQ scores were validated against the ability to make measurements and, when all measurements were made, variation between sonographers. After validation, patient and lab factors, from a previously published survey, associated with improved TTE IQ were determined by linear regression. Total IQ score (R2 = 0.64), ACC QNet (R2 = 0.29) and the Likert component (R2 = 0.52) correlated with the total number of measurements made (p < 0.001). For the 236 (52%) TTEs with all measurements, the Likert scale component (OR 0.9, 95% CI 0.82-0.99, p = 0.037) was associated with lower measurement variability. Factors significantly associated with worse IQ scores were higher patient weight, performance by a traveling sonographer, lower annual and inpatient TTE volume, less dedicated teaching/administrative sonographer time, and full-day sessions for reading physicians. A novel TTE IQ scoring tool was created and validated for pediatric TTE. Modifiable structural components of echo labs associated with TTE IQ were identified. This novel IQ tool should guide IQ beyond the ACC QNet score.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
确定影响儿童回声实验室图像质量的因素:一种新的评估工具的开发和验证。
目前尚无评估经胸超声心动图(TTE)图像质量(IQ)的方法。此外,影响智商的结构回波实验室因素尚不清楚。我们试图开发和验证TTE IQ评分工具,并确定与IQ相关的患者和回声实验室特征。10个儿科超声实验室分别连续提交了50例无复杂心脏病的新患者。在每项研究中,3名超声波技师独立评定智商并进行常规测量。智商评分使用美国心脏病学会质量网络(ACC QNet)工具加上一种新颖的李克特量表成分。智商分数是根据测量的能力来验证的,当所有的测量都完成时,超声波检查人员之间的差异。经过验证后,通过线性回归确定了患者和实验室因素(来自先前发表的调查)与TTE IQ提高相关。总智商得分(R2 = 0.64)、ACC QNet (R2 = 0.29)和李克特分量(R2 = 0.52)与总测量次数相关(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pediatric Cardiology
Pediatric Cardiology 医学-小儿科
CiteScore
3.30
自引率
6.20%
发文量
258
审稿时长
12 months
期刊介绍: The editor of Pediatric Cardiology welcomes original manuscripts concerning all aspects of heart disease in infants, children, and adolescents, including embryology and anatomy, physiology and pharmacology, biochemistry, pathology, genetics, radiology, clinical aspects, investigative cardiology, electrophysiology and echocardiography, and cardiac surgery. Articles which may include original articles, review articles, letters to the editor etc., must be written in English and must be submitted solely to Pediatric Cardiology.
期刊最新文献
Cardiovascular Performance in Neonates with Hypoxic-Ischemic Encephalopathy Under Therapeutic Hypothermia: Evaluation by Conventional and Advanced Echocardiographic Techniques. Pleural Drainage, Clinical Characteristics, and Management Strategies in the Perioperative Fontan Patient: A Multicenter Report. The Role of Fetal Echocardiography in Predicting Postnatal Pulmonary Venous Obstruction in Neonates with TAPVR: A Single Center Experience. Pulmonary Atresia with Intact Ventricular Septum, an Evolving Strategy in the Era of PDA Stenting: Single Center Experience. Evaluating the Sapien® XT Valve in Native Right Ventricular Outflow Tracts After Tetralogy of Fallot Repair: Mid- and Long-Term Results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1