Current concepts of fourth-generation minimally invasive and open hallux valgus surgery.

IF 4.9 1区 医学 Q1 ORTHOPEDICS Bone & Joint Journal Pub Date : 2025-01-01 DOI:10.1302/0301-620X.107B1.BJJ-2024-0597.R2
Thomas L Lewis, Ahmed Barakat, Jitendra Mangwani, Arul Ramasamy, Robbie Ray
{"title":"Current concepts of fourth-generation minimally invasive and open hallux valgus surgery.","authors":"Thomas L Lewis, Ahmed Barakat, Jitendra Mangwani, Arul Ramasamy, Robbie Ray","doi":"10.1302/0301-620X.107B1.BJJ-2024-0597.R2","DOIUrl":null,"url":null,"abstract":"<p><p>Hallux valgus (HV) presents as a common forefoot deformity that causes problems with pain, mobility, footwear, and quality of life. The most common open correction used in the UK is the Scarf and Akin osteotomy, which has good clinical and radiological outcomes and high levels of patient satisfaction when used to treat a varying degrees of deformity. However, there are concerns regarding recurrence rates and long-term outcomes. Minimally invasive or percutaneous surgery (MIS) has gained popularity, offering the potential for similar clinical and radiological outcomes with reduced postoperative pain and smaller scars. Despite this, MIS techniques vary widely, hindering comparison and standardization. This review evaluates the evidence for both open Scarf and Akin osteotomy and newer-generation MIS techniques. Fourth-generation MIS emphasizes multiplanar rotational deformity correction through stable fixation. While MIS techniques show promise, their evidence mainly comprises single-surgeon case series. Comparative studies between open and MIS techniques suggest similar clinical and radiological outcomes, although MIS may offer advantages in scar length and less early postoperative pain. MIS may afford superior correction in severe deformity and lower recurrence rates due to correcting the bony deformity rather than soft-tissue correction. Recurrence remains a challenge in HV surgery, necessitating long-term follow-up and standardized outcome measures for assessment. Any comparison between the techniques requires comparative studies. Surgeons must weigh the advantages and risks of both open and MIS approaches in collaboration with patients to determine the most suitable treatment.</p>","PeriodicalId":48944,"journal":{"name":"Bone & Joint Journal","volume":"107-B 1","pages":"10-18"},"PeriodicalIF":4.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/0301-620X.107B1.BJJ-2024-0597.R2","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Hallux valgus (HV) presents as a common forefoot deformity that causes problems with pain, mobility, footwear, and quality of life. The most common open correction used in the UK is the Scarf and Akin osteotomy, which has good clinical and radiological outcomes and high levels of patient satisfaction when used to treat a varying degrees of deformity. However, there are concerns regarding recurrence rates and long-term outcomes. Minimally invasive or percutaneous surgery (MIS) has gained popularity, offering the potential for similar clinical and radiological outcomes with reduced postoperative pain and smaller scars. Despite this, MIS techniques vary widely, hindering comparison and standardization. This review evaluates the evidence for both open Scarf and Akin osteotomy and newer-generation MIS techniques. Fourth-generation MIS emphasizes multiplanar rotational deformity correction through stable fixation. While MIS techniques show promise, their evidence mainly comprises single-surgeon case series. Comparative studies between open and MIS techniques suggest similar clinical and radiological outcomes, although MIS may offer advantages in scar length and less early postoperative pain. MIS may afford superior correction in severe deformity and lower recurrence rates due to correcting the bony deformity rather than soft-tissue correction. Recurrence remains a challenge in HV surgery, necessitating long-term follow-up and standardized outcome measures for assessment. Any comparison between the techniques requires comparative studies. Surgeons must weigh the advantages and risks of both open and MIS approaches in collaboration with patients to determine the most suitable treatment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
目前第四代微创开放性外翻手术的概念。
拇外翻(HV)是一种常见的前足畸形,会导致疼痛、活动、穿鞋和生活质量等问题。在英国最常用的开放式矫正是Scarf和Akin截骨术,用于治疗不同程度的畸形时,具有良好的临床和放射学效果,患者满意度高。然而,人们担心复发率和长期预后。微创或经皮手术(MIS)越来越受欢迎,提供了类似的临床和放射学结果的潜力,减少了术后疼痛和较小的疤痕。尽管如此,管理信息系统技术差异很大,妨碍了比较和标准化。本综述评估了开放式Scarf和Akin截骨术以及新一代MIS技术的证据。第四代MIS强调通过稳定固定进行多平面旋转畸形矫正。虽然MIS技术显示出希望,但其证据主要包括单一外科医生的病例系列。开放式和MIS技术的比较研究表明,尽管MIS技术在疤痕长度和术后早期疼痛较少方面具有优势,但其临床和放射学结果相似。MIS可以对严重畸形提供更好的矫正,并且由于矫正骨畸形而不是软组织矫正,复发率较低。复发仍然是HV手术的挑战,需要长期随访和标准化的结果评估措施。技术之间的任何比较都需要比较研究。外科医生必须与患者合作权衡开放和MIS方法的优势和风险,以确定最合适的治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bone & Joint Journal
Bone & Joint Journal ORTHOPEDICS-SURGERY
CiteScore
9.40
自引率
10.90%
发文量
318
期刊介绍: We welcome original articles from any part of the world. The papers are assessed by members of the Editorial Board and our international panel of expert reviewers, then either accepted for publication or rejected by the Editor. We receive over 2000 submissions each year and accept about 250 for publication, many after revisions recommended by the reviewers, editors or statistical advisers. A decision usually takes between six and eight weeks. Each paper is assessed by two reviewers with a special interest in the subject covered by the paper, and also by members of the editorial team. Controversial papers will be discussed at a full meeting of the Editorial Board. Publication is between four and six months after acceptance.
期刊最新文献
Advances in foot and ankle surgery : a review of recent innovations. An analysis of the usage and limitations of the T1 pelvic angle. Analysis of national real-world data on reoperations after medial unicompartmental knee arthroplasty : insights from a high-usage country. Distinct age-related modes of failure in cemented and cementless Oxford medial unicompartmental knee arthroplasty : results from 25,762 patients in the Dutch Arthroplasty Register. The risk of complications after hip fracture.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1