Assessment of fully quantitative and simplified methods for analysis of [68Ga]Ga-FAPI-46 uptake in patients with pancreatobiliary cancer using LAFOV PET/CT

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING European Journal of Nuclear Medicine and Molecular Imaging Pub Date : 2025-01-02 DOI:10.1007/s00259-024-07037-6
Xavier Palard-Novello, Rutger B. Henrar, Daniela E. Oprea-Lager, Matthijs C. F. Cysouw, Patrick Schober, Lioe-Fee de Geus-Oei, Alexander L. Vahrmeijer, Harry Hendrikse, Geert Kazemier, Marijke den Hollander, Robert C. Schuit, Albert D. Windhorst, Ronald Boellaard, Rutger-Jan Swijnenburg, Maqsood Yaqub
{"title":"Assessment of fully quantitative and simplified methods for analysis of [68Ga]Ga-FAPI-46 uptake in patients with pancreatobiliary cancer using LAFOV PET/CT","authors":"Xavier Palard-Novello, Rutger B. Henrar, Daniela E. Oprea-Lager, Matthijs C. F. Cysouw, Patrick Schober, Lioe-Fee de Geus-Oei, Alexander L. Vahrmeijer, Harry Hendrikse, Geert Kazemier, Marijke den Hollander, Robert C. Schuit, Albert D. Windhorst, Ronald Boellaard, Rutger-Jan Swijnenburg, Maqsood Yaqub","doi":"10.1007/s00259-024-07037-6","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>The aim of this study was to validate simplified methods for quantifying [<sup>68</sup>Ga]Ga-FAPI-46 uptake against full pharmacokinetic modeling.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>Ten patients with pancreatobiliary cancer underwent a 90-min dynamic PET/CT scan using a long axial field of view system. Arterial blood samples were used to establish calibrated plasma-input function from both continuous arterial sampling and image-derived input function (IDIF). Lesional [<sup>68</sup>Ga]Ga-FAPI-46 kinetics were described using conventional non-linear plasma-input tissue-compartment models. Logan plots using 30–90 min and 30–60 min post-injection (p.i), image-based target-to-whole blood ratio (TBR), mean standardized uptake values (SUVmean) normalized to body weight, lean body mass, and body surface area, at 20–30 min, 60–70 min and 80–90 min p.i were assessed.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>One patient was excluded due to discontinued scan acquisition and missing arterial sampling. Thirteen tumoral lesions and 11 non-tumoral lesions were included. A reversible 2-tissue-compartment model showed most preferrable fits for all types of [<sup>68</sup>Ga]Ga-FAPI-46 positive lesions. The distribution volume (V<sub>T</sub>) results obtained using arterial sampling plasma-input function and those using plasma-IDIF (V<sub>T_plasma_IDIF</sub>) showed an excellent correlation (Spearman rank correlation coefficient (r<sub>s</sub>) = 0.949). Logan V<sub>T</sub> using both time intervals were highly correlated with V<sub>T_plasma_IDIF</sub> (r<sub>s</sub> ≥ 0.938). The correlation values with V<sub>T_plasma_IDIF</sub> for image-based TBR and SUVmean parameters were higher at 80–90 min (r<sub>s</sub> ≥ 0.839) and at 60–70 min (r<sub>s</sub> ≥ 0.835) p.i than at 20–30 min p.i (r<sub>s</sub> ≤ 0.774).</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>Image-based TBR and SUVmean at 60–70 min p.i are suitable for quantifying [<sup>68</sup>Ga]Ga-FAPI-46 uptake.</p><h3 data-test=\"abstract-sub-heading\">Trial registration</h3><p>EudraCT, EudraCT 2022-001867-29. Registered 02 November 2022.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":"14 1","pages":""},"PeriodicalIF":8.6000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-07037-6","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The aim of this study was to validate simplified methods for quantifying [68Ga]Ga-FAPI-46 uptake against full pharmacokinetic modeling.

Methods

Ten patients with pancreatobiliary cancer underwent a 90-min dynamic PET/CT scan using a long axial field of view system. Arterial blood samples were used to establish calibrated plasma-input function from both continuous arterial sampling and image-derived input function (IDIF). Lesional [68Ga]Ga-FAPI-46 kinetics were described using conventional non-linear plasma-input tissue-compartment models. Logan plots using 30–90 min and 30–60 min post-injection (p.i), image-based target-to-whole blood ratio (TBR), mean standardized uptake values (SUVmean) normalized to body weight, lean body mass, and body surface area, at 20–30 min, 60–70 min and 80–90 min p.i were assessed.

Results

One patient was excluded due to discontinued scan acquisition and missing arterial sampling. Thirteen tumoral lesions and 11 non-tumoral lesions were included. A reversible 2-tissue-compartment model showed most preferrable fits for all types of [68Ga]Ga-FAPI-46 positive lesions. The distribution volume (VT) results obtained using arterial sampling plasma-input function and those using plasma-IDIF (VT_plasma_IDIF) showed an excellent correlation (Spearman rank correlation coefficient (rs) = 0.949). Logan VT using both time intervals were highly correlated with VT_plasma_IDIF (rs ≥ 0.938). The correlation values with VT_plasma_IDIF for image-based TBR and SUVmean parameters were higher at 80–90 min (rs ≥ 0.839) and at 60–70 min (rs ≥ 0.835) p.i than at 20–30 min p.i (rs ≤ 0.774).

Conclusion

Image-based TBR and SUVmean at 60–70 min p.i are suitable for quantifying [68Ga]Ga-FAPI-46 uptake.

Trial registration

EudraCT, EudraCT 2022-001867-29. Registered 02 November 2022.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
LAFOV PET/CT分析胰胆癌患者[68Ga]Ga-FAPI-46摄取的完全定量和简化方法的评估
目的通过建立全药代动力学模型,验证[68Ga]Ga-FAPI-46摄取定量的简化方法。方法10例胰胆癌患者采用长轴向视野系统进行90 min动态PET/CT扫描。通过动脉连续采样和图像衍生输入函数(IDIF),利用动脉血样本建立校准后的血浆输入函数。病变[68Ga]Ga-FAPI-46动力学使用传统的非线性等离子体输入组织室模型进行描述。Logan图采用注射后30-90分钟和30-60分钟(p.i)、基于图像的靶血与全血比(TBR)、平均标准化摄取值(SUVmean)在20-30分钟、60-70分钟和80-90分钟(p.i)归一化为体重、瘦体重和体表面积进行评估。结果1例患者因扫描采集中断和动脉采样缺失而被排除。包括13个肿瘤病变和11个非肿瘤病变。可逆2组织室模型最适合于所有类型的[68Ga]Ga-FAPI-46阳性病变。动脉采样血浆输入函数与血浆idif (VT_plasma_IDIF)的分布体积(VT)结果具有极好的相关性(Spearman秩相关系数(rs) = 0.949)。两种时间间隔Logan VT与VT_plasma_IDIF高度相关(rs≥0.938)。基于图像的TBR和SUVmean参数与VT_plasma_IDIF在80 ~ 90 min (rs≥0.839)和60 ~ 70 min (rs≥0.835)的相关性高于20 ~ 30 min (rs≤0.774)。结论基于图像的TBR和SUVmean在60-70 min p.i可用于定量[68Ga]Ga-FAPI-46摄取。试验注册EudraCT, EudraCT 2022-001867-29。注册于2022年11月02日。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
期刊最新文献
Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner A hybrid [18F]fluoropivalate PET-multiparametric MRI to detect and characterise brain tumour metastases based on a permissive environment for monocarboxylate transport Robust whole-body PET image denoising using 3D diffusion models: evaluation across various scanners, tracers, and dose levels Optimizing MR-based attenuation correction in hybrid PET/MR using deep learning: validation with a flatbed insert and consistent patient positioning Unveiling the potential of copper-61 vs. gallium-68 for SSTR PET imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1