A fully integrated microfluidic cartridge for rapid and ultrasensitive nucleic acid detection from oropharyngeal swabs†

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS Lab on a Chip Pub Date : 2025-01-03 DOI:10.1039/D4LC00770K
Bao Li, Baobao Lin, Wu Zeng, Yin Gu, Yulan Zhao and Peng Liu
{"title":"A fully integrated microfluidic cartridge for rapid and ultrasensitive nucleic acid detection from oropharyngeal swabs†","authors":"Bao Li, Baobao Lin, Wu Zeng, Yin Gu, Yulan Zhao and Peng Liu","doi":"10.1039/D4LC00770K","DOIUrl":null,"url":null,"abstract":"<p >Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs. In this study, we developed a novel, integrated microfluidic cartridge featuring a unique needle-plug/piston microvalve, which enables stable long-term reagent storage and flexible liquid handling for on-site nucleic acid analysis. Coupled with <em>in situ</em> tetra-primer recombinase polymerase amplification (tp-RPA), we achieved highly sensitive nucleic acid detection with a remarkable limit of detection of 20 copies per mL (0.02 copies per μL) and a short turnaround time of less than 30 minutes. To validate this assay, we tested 48 oropharyngeal swab samples. The positive detection rate reached 64.58% (31/48), significantly exceeding the approximately 50% positive detection rate of the traditional RT-PCR method. Furthermore, our assay demonstrated a 100% concordance rate with RT-PCR in detecting positive samples. Thus, we believe our microfluidic nucleic acid analysis system represents a promising approach for enabling rapid and ultrasensitive nucleic acid detection of pathogenic microorganisms in resource-limited settings and low-income areas.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" 3","pages":" 454-464"},"PeriodicalIF":6.1000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/lc/d4lc00770k","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs. In this study, we developed a novel, integrated microfluidic cartridge featuring a unique needle-plug/piston microvalve, which enables stable long-term reagent storage and flexible liquid handling for on-site nucleic acid analysis. Coupled with in situ tetra-primer recombinase polymerase amplification (tp-RPA), we achieved highly sensitive nucleic acid detection with a remarkable limit of detection of 20 copies per mL (0.02 copies per μL) and a short turnaround time of less than 30 minutes. To validate this assay, we tested 48 oropharyngeal swab samples. The positive detection rate reached 64.58% (31/48), significantly exceeding the approximately 50% positive detection rate of the traditional RT-PCR method. Furthermore, our assay demonstrated a 100% concordance rate with RT-PCR in detecting positive samples. Thus, we believe our microfluidic nucleic acid analysis system represents a promising approach for enabling rapid and ultrasensitive nucleic acid detection of pathogenic microorganisms in resource-limited settings and low-income areas.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于口咽拭子快速和超灵敏核酸检测的完全集成的微流控盒。
快速和准确的分子诊断对于预防新发传染病的全球传播至关重要。然而,目前核酸检测的金标准,逆转录聚合酶链反应(RT-PCR),严重依赖于传统的磁珠或二氧化硅膜进行核酸提取,导致一些限制,包括耗时的过程,需要训练有素的人员和复杂的设备。因此,迫切需要一种操作简单、快速、灵敏度高、全集成的核酸检测技术来满足临床的需求。在这项研究中,我们开发了一种新型的集成微流体盒,该盒具有独特的针塞/活塞微阀,可实现稳定的长期试剂储存和灵活的液体处理,用于现场核酸分析。结合原位四引物重组酶聚合酶扩增(tp-RPA),我们获得了高灵敏度的核酸检测,检测限为20拷贝/ mL(0.02拷贝/ μL),周转时间短,不到30分钟。为了验证这一分析,我们测试了48个口咽拭子样本。阳性检出率达64.58%(31/48),明显超过传统RT-PCR方法约50%的阳性检出率。此外,在检测阳性样本时,我们的分析显示与RT-PCR的一致性为100%。因此,我们相信我们的微流控核酸分析系统代表了一种有前途的方法,可以在资源有限的环境和低收入地区对病原微生物进行快速和超灵敏的核酸检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Advances of dual-organ and multi-organ systems for gut, lung, skin and liver models in absorption and metabolism studies. Soft, wearable, microfluidic system for fluorometric analysis of loss of amino acids through eccrine sweat. Advances in modeling periodontal host-microbe interactions: insights from organotypic and organ-on-chip systems. Dimensional analysis meets AI for non-Newtonian droplet generation. iDEP-based single-cell isolation in a two-dimensional array of chambers addressed by easy-to-align wireless electrodes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1