3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations.

IF 3 2区 医学 Q1 SURGERY Aesthetic Surgery Journal Pub Date : 2025-01-03 DOI:10.1093/asj/sjae251
Ioannis Kyriazidis, Juan Enrique Berner, Karl Waked, Moustapha Hamdi
{"title":"3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations.","authors":"Ioannis Kyriazidis, Juan Enrique Berner, Karl Waked, Moustapha Hamdi","doi":"10.1093/asj/sjae251","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Three-dimensional (3D) imaging enhances surgical planning and documentation in plastic surgery, but high costs limit accessibility. Mobile Light Detection and Ranging (LiDAR) technology offers a potential cost-effective alternative.</p><p><strong>Objectives: </strong>To evaluate the accuracy and clinical utility of iPhone-based LiDAR scanning for breast measurements compared to traditional methods, and to establish standardized protocols for clinical implementation.</p><p><strong>Methods: </strong>In this prospective validation study, 25 consecutive patients (mean age: 44 years; range: 32-64 years; mean BMI: 23.2 kg/m²) undergoing breast procedures were evaluated using the \"3D Scanner App\" on iPhone 15 Pro (Apple Inc., Cupertino, CA). Three standardized measurements (sternal notch-to-nipple, nipple-to-midline, nipple-to-inframammary fold) were compared between LiDAR and manual techniques. Technical error of measurement (TEM) and relative TEM (rTEM) were calculated. Inter-rater reliability, learning curve assessment, and cost-effectiveness analysis were performed.</p><p><strong>Results: </strong>LiDAR measurements showed very good accuracy for sternal notch-to-nipple (rTEM 1.43%, 95% CI: 1.21-1.65) and nipple-to-midline distances (rTEM 3.45%, 95% CI: 3.12-3.78). Nipple-to-inframammary fold measurements showed moderate accuracy (rTEM 8.80%, 95% CI: 8.21-9.39). Inter-rater reliability was excellent (ICC=0.92). Learning curve analysis demonstrated measurement stability after 5 cases. Cost analysis revealed 97.8% reduction in initial investment compared to commercial 3D imaging systems.</p><p><strong>Conclusions: </strong>Mobile LiDAR technology provides accurate breast measurements for most anatomical landmarks at a fraction of the cost of traditional 3D imaging systems. The technology shows excellent reliability after a short learning curve, offering an accessible solution for surgical planning and documentation.</p>","PeriodicalId":7728,"journal":{"name":"Aesthetic Surgery Journal","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aesthetic Surgery Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/asj/sjae251","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Three-dimensional (3D) imaging enhances surgical planning and documentation in plastic surgery, but high costs limit accessibility. Mobile Light Detection and Ranging (LiDAR) technology offers a potential cost-effective alternative.

Objectives: To evaluate the accuracy and clinical utility of iPhone-based LiDAR scanning for breast measurements compared to traditional methods, and to establish standardized protocols for clinical implementation.

Methods: In this prospective validation study, 25 consecutive patients (mean age: 44 years; range: 32-64 years; mean BMI: 23.2 kg/m²) undergoing breast procedures were evaluated using the "3D Scanner App" on iPhone 15 Pro (Apple Inc., Cupertino, CA). Three standardized measurements (sternal notch-to-nipple, nipple-to-midline, nipple-to-inframammary fold) were compared between LiDAR and manual techniques. Technical error of measurement (TEM) and relative TEM (rTEM) were calculated. Inter-rater reliability, learning curve assessment, and cost-effectiveness analysis were performed.

Results: LiDAR measurements showed very good accuracy for sternal notch-to-nipple (rTEM 1.43%, 95% CI: 1.21-1.65) and nipple-to-midline distances (rTEM 3.45%, 95% CI: 3.12-3.78). Nipple-to-inframammary fold measurements showed moderate accuracy (rTEM 8.80%, 95% CI: 8.21-9.39). Inter-rater reliability was excellent (ICC=0.92). Learning curve analysis demonstrated measurement stability after 5 cases. Cost analysis revealed 97.8% reduction in initial investment compared to commercial 3D imaging systems.

Conclusions: Mobile LiDAR technology provides accurate breast measurements for most anatomical landmarks at a fraction of the cost of traditional 3D imaging systems. The technology shows excellent reliability after a short learning curve, offering an accessible solution for surgical planning and documentation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3D乳房扫描在整形外科利用免费的iPhone激光雷达应用程序:评估,潜力和局限性。
背景:三维(3D)成像增强了整形外科的手术规划和记录,但高昂的成本限制了其普及。移动光探测与测距(LiDAR)技术提供了一种潜在的经济高效的替代方案:与传统方法相比,评估基于 iPhone 的激光雷达扫描乳房测量的准确性和临床实用性,并建立临床实施的标准化协议:在这项前瞻性验证研究中,使用 iPhone 15 Pro(苹果公司,加利福尼亚州库比蒂诺)上的 "3D 扫描仪应用程序 "对 25 名连续接受乳房手术的患者(平均年龄:44 岁;范围:32-64 岁;平均体重指数:23.2 kg/m²)进行了评估。比较了激光雷达和人工技术的三种标准化测量结果(胸骨切迹至乳头、乳头至中线、乳头至乳房内皱褶)。计算了测量的技术误差(TEM)和相对 TEM(rTEM)。结果显示,激光雷达测量结果显示出非常高的准确性:激光雷达测量显示胸骨切迹到乳头(rTEM 1.43%,95% CI:1.21-1.65)和乳头到中线的距离(rTEM 3.45%,95% CI:3.12-3.78)非常准确。乳头至乳房内皱褶的测量结果显示出中等准确度(rTEM 8.80%,95% CI:8.21-9.39)。评分者之间的可靠性极佳(ICC=0.92)。学习曲线分析表明,5 个病例后测量结果稳定。成本分析显示,与商用 3D 成像系统相比,初始投资减少了 97.8%:移动激光雷达技术能对大多数解剖标志物进行精确的乳房测量,而成本仅为传统三维成像系统的一小部分。经过短暂的学习曲线后,该技术显示出极佳的可靠性,为手术规划和记录提供了便捷的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
20.70%
发文量
309
审稿时长
6-12 weeks
期刊介绍: Aesthetic Surgery Journal is a peer-reviewed international journal focusing on scientific developments and clinical techniques in aesthetic surgery. The official publication of The Aesthetic Society, ASJ is also the official English-language journal of many major international societies of plastic, aesthetic and reconstructive surgery representing South America, Central America, Europe, Asia, and the Middle East. It is also the official journal of the British Association of Aesthetic Plastic Surgeons, the Canadian Society for Aesthetic Plastic Surgery and The Rhinoplasty Society.
期刊最新文献
Arterioembolic Characteristics of Differentially Diluted CaHA-CMC Gels Within an Artificial Macrovascular Perfusion Model. The Occurrence of Health Symptoms in General Practice Before and After the Explantation of Cosmetic Breast Implants. Correction to: Breast Pocket Lavage With Clindamycin Solution for Silicone Removal After Implant Rupture. Adverse Childhood Experiences (ACEs) in 252 Board-Certified Plastic Surgeons: Prevalences, ACE Clustering, and Effects on Adult Health and Behaviors, Including Self-Defined Depression, Work Addiction, and Burnout. IncobotulinumtoxinA in the Treatment of Upper Facial Lines: Results From Two Randomized, Double-Blind, Placebo-Controlled, Phase III Studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1