Artifacts at Cardiac MRI: Imaging Appearances and Solutions.

IF 5.2 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiographics Pub Date : 2025-01-01 DOI:10.1148/rg.230200
Prabhakar Shantha Rajiah, Baskaran Sundaram, Ming Yen Ng, Praveen Ranganath, Philip A Araoz, Michael A Bolen
{"title":"Artifacts at Cardiac MRI: Imaging Appearances and Solutions.","authors":"Prabhakar Shantha Rajiah, Baskaran Sundaram, Ming Yen Ng, Praveen Ranganath, Philip A Araoz, Michael A Bolen","doi":"10.1148/rg.230200","DOIUrl":null,"url":null,"abstract":"<p><p>Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR. Balanced steady-state free precession (bSSFP), the most common CMR sequence, is associated with band and flow artifacts, which are amplified at 3-T imaging. This can be mitigated by targeted shimming, by short repetition time, or by using a frequency-scout sequence. In patients with cardiac arrhythmias or poor breath hold, the quality of cine imaging can be improved with a non-electrocardiographically gated free-breathing real-time sequence. Motion artifacts on late gadolinium enhancement (LGE) images can be mitigated by using single-shot technique with motion compensation and signal averaging. LGE images are also prone to partial-volume averaging and incomplete myocardial nulling. In phase-contrast imaging, aliasing artifact is seen when the velocity of blood is higher than the encoded velocity. Aliasing can be mitigated by increasing the encoded velocity or using postprocessing software. In first-pass perfusion imaging, a dark rim artifact due to Gibbs ringing can be distinguished from a true perfusion defect based on earlier appearance and fading after a few cardiac cycles. With implanted cardiac devices, artifactual high signal intensity mimicking scar is seen on LGE images, which can be mitigated using a wide-band sequence. With devices and metallic artifacts, traditional gradient-recalled echo sequence has fewer artifacts than bSSFP. CMR at 3 T requires adaptation of sequences to minimize artifacts. <sup>©</sup>RSNA, 2025 <i>Supplemental material is available for this article.</i></p>","PeriodicalId":54512,"journal":{"name":"Radiographics","volume":"45 1","pages":"e230200"},"PeriodicalIF":5.2000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiographics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1148/rg.230200","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR. Balanced steady-state free precession (bSSFP), the most common CMR sequence, is associated with band and flow artifacts, which are amplified at 3-T imaging. This can be mitigated by targeted shimming, by short repetition time, or by using a frequency-scout sequence. In patients with cardiac arrhythmias or poor breath hold, the quality of cine imaging can be improved with a non-electrocardiographically gated free-breathing real-time sequence. Motion artifacts on late gadolinium enhancement (LGE) images can be mitigated by using single-shot technique with motion compensation and signal averaging. LGE images are also prone to partial-volume averaging and incomplete myocardial nulling. In phase-contrast imaging, aliasing artifact is seen when the velocity of blood is higher than the encoded velocity. Aliasing can be mitigated by increasing the encoded velocity or using postprocessing software. In first-pass perfusion imaging, a dark rim artifact due to Gibbs ringing can be distinguished from a true perfusion defect based on earlier appearance and fading after a few cardiac cycles. With implanted cardiac devices, artifactual high signal intensity mimicking scar is seen on LGE images, which can be mitigated using a wide-band sequence. With devices and metallic artifacts, traditional gradient-recalled echo sequence has fewer artifacts than bSSFP. CMR at 3 T requires adaptation of sequences to minimize artifacts. ©RSNA, 2025 Supplemental material is available for this article.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiographics
Radiographics 医学-核医学
CiteScore
8.20
自引率
5.50%
发文量
224
审稿时长
4-8 weeks
期刊介绍: Launched by the Radiological Society of North America (RSNA) in 1981, RadioGraphics is one of the premier education journals in diagnostic radiology. Each bimonthly issue features 15–20 practice-focused articles spanning the full spectrum of radiologic subspecialties and addressing topics such as diagnostic imaging techniques, imaging features of a disease or group of diseases, radiologic-pathologic correlation, practice policy and quality initiatives, imaging physics, informatics, and lifelong learning. A special issue, a monograph focused on a single subspecialty or on a crossover topic of interest to multiple subspecialties, is published each October. Each issue offers more than a dozen opportunities to earn continuing medical education credits that qualify for AMA PRA Category 1 CreditTM and all online activities can be applied toward the ABR MOC Self-Assessment Requirement.
期刊最新文献
Anatomic Approach to Fetal Hydrocephalus. Classic Signs on Chest Radiographs: Primer for Residents. False-Negative Review from the Mammography Audit: Refining Breast Imaging Practice. Invited Commentary: BI-RADS Category 3: Guidelines, Challenges, and the Path Forward. Motor Neuron Diseases and Central Nervous System Tractopathies: Clinical-Radiologic Correlation and Diagnostic Approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1