Microwave-Sintered Nano-SiC Reinforced 8SiC/Ti-3Cu Composite: Fabrication, Wear Resistance, Antibacterial Function, and Biocompatibility.

IF 10 2区 医学 Q1 ENGINEERING, BIOMEDICAL Advanced Healthcare Materials Pub Date : 2025-01-05 DOI:10.1002/adhm.202403626
Xin Li, Ying-Chao Zhao, Dengfeng Yin, Ying Cai, Desheng Xiao, Ming-Chun Zhao, Cuie Wen, Andrej Atrens
{"title":"Microwave-Sintered Nano-SiC Reinforced 8SiC/Ti-3Cu Composite: Fabrication, Wear Resistance, Antibacterial Function, and Biocompatibility.","authors":"Xin Li, Ying-Chao Zhao, Dengfeng Yin, Ying Cai, Desheng Xiao, Ming-Chun Zhao, Cuie Wen, Andrej Atrens","doi":"10.1002/adhm.202403626","DOIUrl":null,"url":null,"abstract":"<p><p>The significance of biomedical applications of Ti alloys is best emphasized by their widespread utilization as implantable materials, such as internal supports and bone replacements. Ti alloys are sensitive to fretting wear, which leads to the early failure of Ti implants. Improved wear resistance of such implants is essential to ensure a prolonged implant life. Based on the structure-function-integrated concept, this work unprecedentedly designs and fabricates an antibacterial 8SiC/Ti-3Cu composite with improved wear resistance using microwave sintering from pure Ti, Cu, and nano-SiC powders. For comparison, SiC-free Ti-3Cu composite is manufactured under the same conditions using microwave sintering. The addition of 8 vol.% SiC to Ti-3Cu significantly reduces the porosity and pore size of composites. The 8SiC/Ti-3Cu shows a Vickers hardness of 353 HV, compressive strength of 803 MPa, elastic modulus of 28.7 GPa, and a significantly increased wear resistance (wear rate decreased by 70% compared to Ti-3Cu). In addition, 8SiC/Ti-3Cu exhibits excellent electrochemical corrosion resistance, biocompatibility in relation to MC3T3-E1 cells, and a bacteriostatic rate over 99% against E. coli. The combination of the wear-resistant nano-reinforced SiC and antibacterial Ti<sub>2</sub>Cu in the 8SiC/Ti-3Cu composite renders it a highly promising implant material.</p>","PeriodicalId":113,"journal":{"name":"Advanced Healthcare Materials","volume":" ","pages":"e2403626"},"PeriodicalIF":10.0000,"publicationDate":"2025-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Healthcare Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/adhm.202403626","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The significance of biomedical applications of Ti alloys is best emphasized by their widespread utilization as implantable materials, such as internal supports and bone replacements. Ti alloys are sensitive to fretting wear, which leads to the early failure of Ti implants. Improved wear resistance of such implants is essential to ensure a prolonged implant life. Based on the structure-function-integrated concept, this work unprecedentedly designs and fabricates an antibacterial 8SiC/Ti-3Cu composite with improved wear resistance using microwave sintering from pure Ti, Cu, and nano-SiC powders. For comparison, SiC-free Ti-3Cu composite is manufactured under the same conditions using microwave sintering. The addition of 8 vol.% SiC to Ti-3Cu significantly reduces the porosity and pore size of composites. The 8SiC/Ti-3Cu shows a Vickers hardness of 353 HV, compressive strength of 803 MPa, elastic modulus of 28.7 GPa, and a significantly increased wear resistance (wear rate decreased by 70% compared to Ti-3Cu). In addition, 8SiC/Ti-3Cu exhibits excellent electrochemical corrosion resistance, biocompatibility in relation to MC3T3-E1 cells, and a bacteriostatic rate over 99% against E. coli. The combination of the wear-resistant nano-reinforced SiC and antibacterial Ti2Cu in the 8SiC/Ti-3Cu composite renders it a highly promising implant material.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Advanced Healthcare Materials
Advanced Healthcare Materials 工程技术-生物材料
CiteScore
14.40
自引率
3.00%
发文量
600
审稿时长
1.8 months
期刊介绍: Advanced Healthcare Materials, a distinguished member of the esteemed Advanced portfolio, has been dedicated to disseminating cutting-edge research on materials, devices, and technologies for enhancing human well-being for over ten years. As a comprehensive journal, it encompasses a wide range of disciplines such as biomaterials, biointerfaces, nanomedicine and nanotechnology, tissue engineering, and regenerative medicine.
期刊最新文献
Insulative Compression of Neuronal Tissues on Microelectrode Arrays by Perfluorodecalin Enhances Electrophysiological Measurements. Microwave-Sintered Nano-SiC Reinforced 8SiC/Ti-3Cu Composite: Fabrication, Wear Resistance, Antibacterial Function, and Biocompatibility. Multifunctional Carbon Dots In Situ Confined Hydrogel for Optical Communication, Drug Delivery, pH Sensing, Nanozymatic Activity, and UV Shielding Applications. Polycationic γ-Cyclodextrin with Amino Side Chains for a Highly Efficient Anti-Heparin Coagulant. Regulating Supramolecular Assembly and Disassembly of Chitosan toward Efficiently Antibacterial Lubricous and Biodegradable Hydrogel Urinary Catheters.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1