Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans.

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2025-01-07 DOI:10.1186/s12903-024-05397-x
Faezeh Yousefi, Ali Heidari, Azita Ehsani, Maryam Farhadian, Marzieh Ehsani
{"title":"Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans.","authors":"Faezeh Yousefi, Ali Heidari, Azita Ehsani, Maryam Farhadian, Marzieh Ehsani","doi":"10.1186/s12903-024-05397-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Early detection of peri-implant bone defects can improve long-term durability of dental implants. By the advances in cone-beam computed tomography (CBCT) scanners and introduction of new algorithms, it is important to find the most efficient protocol for detection of bone defects. This study aimed to assess the efficacy of metal artifact reduction (MAR) and advanced noise reduction (ANR) algorithms for detection of peri-implant bone defects.</p><p><strong>Materials and methods: </strong>In this in vitro study, 40 titanium implants were placed in 7 sheep mandibles. Crestal, apical, and Full defects (n = 10 from each type) were created around the implants, and 10 implants were also placed as controls. CBCT scans were obtained in four modes: with MAR, with ANR, with both MAR and ANR, and without any filter. Totally, 28 scans were obtained and evaluated by a radiologist and a maxillofacial surgeon. The observers recorded their observations in a checklist, and data were analyzed by SPSS version 21 using the kappa coefficient of agreement, sensitivity and specificity values, area under the receiver operating characteristic (ROC) curve (AUC), intraclass correlation coefficient, t-test and paired t-test (P < 0.05).</p><p><strong>Results: </strong>The inter-observer agreement was high for detection of all defects in all modes except with ANR. No significant difference was found in AUC and diagnostic accuracy of different scan modes (P > 0.05). The most common diagnostic error was related to misdiagnosis of control group with full defect with ANR filter, such that the existing bone was not detected. Defect depth was averagely over-estimated while defect length was under-estimated. Correct diagnosis of defects had the highest frequency when both filters were on.</p><p><strong>Conclusion: </strong>The diagnostic accuracy and sensitivity for detection of different defect types were not significantly different in different scan modes but activation of ANR filter significantly decreased the specificity and positive predictive value compared with no use of filter.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"39"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11708108/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-024-05397-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Early detection of peri-implant bone defects can improve long-term durability of dental implants. By the advances in cone-beam computed tomography (CBCT) scanners and introduction of new algorithms, it is important to find the most efficient protocol for detection of bone defects. This study aimed to assess the efficacy of metal artifact reduction (MAR) and advanced noise reduction (ANR) algorithms for detection of peri-implant bone defects.

Materials and methods: In this in vitro study, 40 titanium implants were placed in 7 sheep mandibles. Crestal, apical, and Full defects (n = 10 from each type) were created around the implants, and 10 implants were also placed as controls. CBCT scans were obtained in four modes: with MAR, with ANR, with both MAR and ANR, and without any filter. Totally, 28 scans were obtained and evaluated by a radiologist and a maxillofacial surgeon. The observers recorded their observations in a checklist, and data were analyzed by SPSS version 21 using the kappa coefficient of agreement, sensitivity and specificity values, area under the receiver operating characteristic (ROC) curve (AUC), intraclass correlation coefficient, t-test and paired t-test (P < 0.05).

Results: The inter-observer agreement was high for detection of all defects in all modes except with ANR. No significant difference was found in AUC and diagnostic accuracy of different scan modes (P > 0.05). The most common diagnostic error was related to misdiagnosis of control group with full defect with ANR filter, such that the existing bone was not detected. Defect depth was averagely over-estimated while defect length was under-estimated. Correct diagnosis of defects had the highest frequency when both filters were on.

Conclusion: The diagnostic accuracy and sensitivity for detection of different defect types were not significantly different in different scan modes but activation of ANR filter significantly decreased the specificity and positive predictive value compared with no use of filter.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
22 months follow-up of deep marginal acquisition with thermacut bur in management of deep subgingival interproximal carious lesions: a case report. Assessment of using transfer learning with different classifiers in hypodontia diagnosis. Outcome of Er, Cr:YSGG laser and antioxidant pretreatments on bonding quality to caries-induced dentin. Treatment of gingival recession with vestibular incision subperiosteal tunnel access and advanced platelet-rich fibrin. Ankyloglossia and breastfeeding self-efficacy in newborns: a birth cohort study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1