Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots (Amazona ventralis).

IF 0.6 4区 农林科学 Q3 VETERINARY SCIENCES Journal of Avian Medicine and Surgery Pub Date : 2025-01-01 DOI:10.1647/AVIANMS-D-23-00050
Laken Russell, Thomas N Tully, M Ryan Smith, Mark A Mitchell
{"title":"Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots (<i>Amazona ventralis</i>).","authors":"Laken Russell, Thomas N Tully, M Ryan Smith, Mark A Mitchell","doi":"10.1647/AVIANMS-D-23-00050","DOIUrl":null,"url":null,"abstract":"<p><p>Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.2 mL of blood and is useful in diagnosing and treating hemostatic disorders. Currently, there is no standardized coagulation testing method across bird species. In this cross-sectional study, a viscoelastic coagulation device, the Entegrion Viscoelastic Coagulation Monitor-Vet (VCM-Vet), was evaluated. Blood samples were obtained from 26 Hispaniolan Amazon parrots (HAPs) (<i>Amazona ventralis</i>) under manual restraint. Results were recorded on the device as graphical output with quantitative viscoelastic measurements. Results were reported using standard rotational thromboelastometry terminology, including clotting time, clot formation time, alpha angle, maximum clot firmness, clot firmness amplitude at 10 and 20 minutes after clot formation, and clot lysis at 30 and 45 minutes. The median clotting time was 463 seconds (reference interval: 56-1635 seconds), the mean clot formation time was 704.7 seconds (reference interval: 172-1697 seconds), the mean alpha angle was 27.3 (reference interval: 7-60), and the mean maximum clot firmness was 15.4 (reference interval: 7-25). Statistical analysis found that all parameters were normally distributed aside from clotting time in seconds. There was no appreciable breakdown of the clot during the 60-minute device runtime, and there was no significant difference in any parameter based on sex. The VCM-Vet produced clotting times for this population of HAPs and enabled the creation of reference intervals. Based on our findings, the VCM-Vet can be used to assess clot potential in HAPs and possibly other avian species.</p>","PeriodicalId":15102,"journal":{"name":"Journal of Avian Medicine and Surgery","volume":"38 4","pages":"188-196"},"PeriodicalIF":0.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Avian Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1647/AVIANMS-D-23-00050","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.2 mL of blood and is useful in diagnosing and treating hemostatic disorders. Currently, there is no standardized coagulation testing method across bird species. In this cross-sectional study, a viscoelastic coagulation device, the Entegrion Viscoelastic Coagulation Monitor-Vet (VCM-Vet), was evaluated. Blood samples were obtained from 26 Hispaniolan Amazon parrots (HAPs) (Amazona ventralis) under manual restraint. Results were recorded on the device as graphical output with quantitative viscoelastic measurements. Results were reported using standard rotational thromboelastometry terminology, including clotting time, clot formation time, alpha angle, maximum clot firmness, clot firmness amplitude at 10 and 20 minutes after clot formation, and clot lysis at 30 and 45 minutes. The median clotting time was 463 seconds (reference interval: 56-1635 seconds), the mean clot formation time was 704.7 seconds (reference interval: 172-1697 seconds), the mean alpha angle was 27.3 (reference interval: 7-60), and the mean maximum clot firmness was 15.4 (reference interval: 7-25). Statistical analysis found that all parameters were normally distributed aside from clotting time in seconds. There was no appreciable breakdown of the clot during the 60-minute device runtime, and there was no significant difference in any parameter based on sex. The VCM-Vet produced clotting times for this population of HAPs and enabled the creation of reference intervals. Based on our findings, the VCM-Vet can be used to assess clot potential in HAPs and possibly other avian species.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Avian Medicine and Surgery
Journal of Avian Medicine and Surgery 农林科学-兽医学
CiteScore
0.90
自引率
0.00%
发文量
52
审稿时长
>36 weeks
期刊介绍: The Journal of Avian Medicine and Surgery is an international journal of the medicine and surgery of both captive and wild birds. Published materials include scientific articles, case reports, editorials, abstracts, new research, and book reviews.
期刊最新文献
Evaluation of a Point-of-Care-Viscoelastic Coagulation Device in Hispaniolan Amazon Parrots (Amazona ventralis). Identification of Candida spp. From the Gastrointestinal Tract of Pet Parrots and Subsequent Antifungal Susceptibility Profiles. Mandibular Prognathism Correction in a Juvenile Umbrella Cockatoo (Cacatua alba) With the Use of an Orthosis. Successful Management of Acetamiprid Intoxication in a Captive Eurasian Goshawk (Accipiter gentilis). Use of Haloperidol in Companion Psittacine Birds: 19 Cases (2012-2022).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1