{"title":"Development and Clinical Evaluation of a Contrast Optimizer for Contrast-Enhanced CT Imaging of the Liver.","authors":"Hananiel Setiawan, Francesco Ria, Ehsan Abadi, Daniele Marin, Lior Molvin, Ehsan Samei","doi":"10.1097/RCT.0000000000001677","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Patient characteristics, iodine injection, and scanning parameters can impact the quality and consistency of contrast enhancement of hepatic parenchyma in CT imaging. Improving the consistency and adequacy of contrast enhancement can enhance diagnostic accuracy and reduce clinical practice variability, with added positive implications for safety and cost-effectiveness in the use of contrast medium. We developed a clinical tool that uses patient attributes (height, weight, sex, age) to predict hepatic enhancement and suggest alternative injection/scanning parameters to optimize the procedure.</p><p><strong>Methods: </strong>The tool was based on a previously validated neural network prediction model that suggested adjustments for patients with predicted insufficient enhancement. We conducted a prospective clinical study in which we tested this tool in 24 patients aiming for a target portal-venous parenchyma CT number of 110 HU ± 10 HU.</p><p><strong>Results: </strong>Out of the 24 patients, 15 received adjustments to their iodine contrast injection parameters, resulting in median reductions of 8.8% in volume and 9.1% in injection rate. The scan delays were reduced by an average of 42.6%. We compared the results with the patients' previous scans and found that the tool improved consistency and reduced the number of underenhanced patients. The median enhancement remained relatively unchanged, but the number of underenhanced patients was reduced by half, and all previously overenhanced patients received enhancement reductions.</p><p><strong>Conclusions: </strong>Our study showed that the proposed patient-informed clinical framework can predict optimal contrast enhancement and suggest empiric injection/scanning parameters to achieve consistent and sufficient contrast enhancement of hepatic parenchyma. The described GUI-based tool can prospectively inform clinical decision-making predicting optimal patient's hepatic parenchyma contrast enhancement. This reduces instances of nondiagnostic/insufficient enhancement in patients.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001677","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Patient characteristics, iodine injection, and scanning parameters can impact the quality and consistency of contrast enhancement of hepatic parenchyma in CT imaging. Improving the consistency and adequacy of contrast enhancement can enhance diagnostic accuracy and reduce clinical practice variability, with added positive implications for safety and cost-effectiveness in the use of contrast medium. We developed a clinical tool that uses patient attributes (height, weight, sex, age) to predict hepatic enhancement and suggest alternative injection/scanning parameters to optimize the procedure.
Methods: The tool was based on a previously validated neural network prediction model that suggested adjustments for patients with predicted insufficient enhancement. We conducted a prospective clinical study in which we tested this tool in 24 patients aiming for a target portal-venous parenchyma CT number of 110 HU ± 10 HU.
Results: Out of the 24 patients, 15 received adjustments to their iodine contrast injection parameters, resulting in median reductions of 8.8% in volume and 9.1% in injection rate. The scan delays were reduced by an average of 42.6%. We compared the results with the patients' previous scans and found that the tool improved consistency and reduced the number of underenhanced patients. The median enhancement remained relatively unchanged, but the number of underenhanced patients was reduced by half, and all previously overenhanced patients received enhancement reductions.
Conclusions: Our study showed that the proposed patient-informed clinical framework can predict optimal contrast enhancement and suggest empiric injection/scanning parameters to achieve consistent and sufficient contrast enhancement of hepatic parenchyma. The described GUI-based tool can prospectively inform clinical decision-making predicting optimal patient's hepatic parenchyma contrast enhancement. This reduces instances of nondiagnostic/insufficient enhancement in patients.
期刊介绍:
The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).