Comparison of Clinical Outcomes and Patient Satisfaction Following SMILE Performed With the VisuMax 800 in One Eye and VisuMax 500 in the Contralateral Eye.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2025-01-01 DOI:10.3928/1081597X-20241113-02
Sri Ganesh, Sheetal Brar, Deepak T Swamy
{"title":"Comparison of Clinical Outcomes and Patient Satisfaction Following SMILE Performed With the VisuMax 800 in One Eye and VisuMax 500 in the Contralateral Eye.","authors":"Sri Ganesh, Sheetal Brar, Deepak T Swamy","doi":"10.3928/1081597X-20241113-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).</p><p><strong>Methods: </strong>This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye. Intraoperative docking time, suction time, laser time, and surgical time were noted. Patient satisfaction and laser preference was evaluated immediately after treatment. Visual and refractive outcomes, contrast sensitivity, and quality of vision were assessed at the 3-month postoperative visit.</p><p><strong>Results: </strong>A total of 30 patients undergoing bilateral SMILE were included. The mean docking time and surgical time were significantly lower in the VM800 group (46.53 ± 11 sec and 4.52 ± 2.33 min, respectively) compared to the VM500 group (68.25 ± 15 sec and 6.22 ± 2.04 min, respectively) (<i>P</i> < .001). No significant differences were observed at the 1-day or 3-month visit for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, higher order aberrations, Objective Scatter Index, modulation transfer function, and contrast sensitivity. Patient scores regarding subjective symptoms were comparable. However, overall satisfaction with the surgical experience was rated significantly better in the VM800 group, with 80% of patients preferring the VM800 eye. No complications occurred for eyes in either group.</p><p><strong>Conclusions: </strong>No significant differences were observed in clinical outcomes between the two laser systems. However, the surgical workflow and patient-reported intraoperative experience favored the VisuMax 800. <b>[<i>J Refract Surg</i>. 2025;41(1):e14-e21.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"41 1","pages":"e14-e21"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20241113-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye. Intraoperative docking time, suction time, laser time, and surgical time were noted. Patient satisfaction and laser preference was evaluated immediately after treatment. Visual and refractive outcomes, contrast sensitivity, and quality of vision were assessed at the 3-month postoperative visit.

Results: A total of 30 patients undergoing bilateral SMILE were included. The mean docking time and surgical time were significantly lower in the VM800 group (46.53 ± 11 sec and 4.52 ± 2.33 min, respectively) compared to the VM500 group (68.25 ± 15 sec and 6.22 ± 2.04 min, respectively) (P < .001). No significant differences were observed at the 1-day or 3-month visit for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, higher order aberrations, Objective Scatter Index, modulation transfer function, and contrast sensitivity. Patient scores regarding subjective symptoms were comparable. However, overall satisfaction with the surgical experience was rated significantly better in the VM800 group, with 80% of patients preferring the VM800 eye. No complications occurred for eyes in either group.

Conclusions: No significant differences were observed in clinical outcomes between the two laser systems. However, the surgical workflow and patient-reported intraoperative experience favored the VisuMax 800. [J Refract Surg. 2025;41(1):e14-e21.].

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单眼使用VisuMax 800和对侧眼使用VisuMax 500进行SMILE术后临床疗效和患者满意度的比较
目的:比较单眼使用VisuMax 800和对侧使用VisuMax 500(均为卡尔蔡司Meditec)进行小切口晶状体摘除(SMILE)后的临床结果、手术流程和患者满意度。方法:这是一项前瞻性、单点临床研究,研究对象是2022年2月至2023年8月期间接受SMILE治疗的近视和近视散光患者。每位患者均接受单眼VisuMax 800 (VM800组)和对侧VisuMax 500 (VM500组)的双侧治疗。记录术中对接时间、吸痰时间、激光时间、手术时间。治疗后立即评估患者满意度和激光偏好。术后3个月随访时评估视力和屈光结果、对比敏感度和视力质量。结果:共纳入30例双侧SMILE患者。VM800组的平均对接时间(46.53±11秒)和手术时间(4.52±2.33分钟)明显低于VM500组(68.25±15秒和6.22±2.04分钟)(P < 0.001)。在随访1天或3个月时,未矫正距离视力、矫正距离视力、球面等效、高阶像差、物镜散射指数、调制传递函数和对比灵敏度均无显著差异。患者主观症状评分具有可比性。然而,VM800组对手术体验的总体满意度明显更高,80%的患者更喜欢VM800眼。两组均未发生眼部并发症。结论:两种激光系统的临床疗效无显著差异。然而,手术流程和患者报告的术中经验更有利于VisuMax 800。[J].中国光学精密工程,2015;41(1):1 - 4。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Visual and Safety Outcomes of Refractive Correction Procedures Following Lens Removal for Residual Refractive Error: A Systematic Review and Meta-analysis. 2024 Reviewers. A Nomogram to Improve the Predictability of High Myopic Astigmatism in Small Incision Lenticule Extraction Surgery. Application of the Taylor Diagram in Evaluating the Performance of IOL Formulas. Clarification of Femtosecond Laser Terminology: Energy, Fluence, Dose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1