The use of laser-assisted cart positioning significantly reduces the docking time of multimodular robotic systems.

IF 3 3区 医学 Q2 SURGERY Journal of Robotic Surgery Pub Date : 2025-01-06 DOI:10.1007/s11701-024-02196-y
Martin Baunacke, Christopher Hirtsiefer, Roman Herout, Sherif Mehralivand, Susanne Oelkers, Oliver Kaske, Claudia Franz, Christian Thomas
{"title":"The use of laser-assisted cart positioning significantly reduces the docking time of multimodular robotic systems.","authors":"Martin Baunacke, Christopher Hirtsiefer, Roman Herout, Sherif Mehralivand, Susanne Oelkers, Oliver Kaske, Claudia Franz, Christian Thomas","doi":"10.1007/s11701-024-02196-y","DOIUrl":null,"url":null,"abstract":"<p><p>The Hugo RAS system is characterized by its multimodular design, which leads to an increased docking effort. Exact data for docking time and the learning curve is missing. We describe for the first time the use of a laser-guided cart positioning to reduce the docking time. In this prospective monocentric study, the docking time was evalutated for a consecutive series of pelvic surgeries with the Hugo RAS system. In a subgroup, a cross-line laser was adapted at the cart for positioning using fix points at the ceiling. The medical personnel were classified as \"inexperienced\" with ≤ 5 consecutive dockings and as \"experienced\" with > 5 consecutive dockings. From 10/2023 to 08/2024, 82 procedures were performed with the Hugo RAS. For the evaluation 75 procedures could be considered. The mean docking time was 7.6 ± 3.5 min. There was a reduction in docking time from 13.5 ± 3.7 min in the first 5 procedures to 4.4 ± 0.9 min in the last 5 procedures (p < 0.001). Docking with laser (n = 45) was faster than without laser (n = 30) (6.2 ± 2.5 vs. 9.8 ± 3.7 min, p < 0.001). Faster docking time was observed with inexperienced surgical nursing staff with laser than without laser (10.4 ± 3.7 vs. 5.4 ± 1.4 min; p < 0.001). With experienced nursing staff, the laser had no influence (6.6 ± 1.3 vs. 6.7 ± 2.9 min; p = 0.9). As a reference docking time for daVinci Xi procedures was 2.4 ± 1.7 min (n = 5). Laser-guided cart positioning has a significant impact on docking time, especially for unexperienced medical personnel. Especially in the times of experienced staff shortage, laser-guided cart positioning can save operating time.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"19 1","pages":"46"},"PeriodicalIF":3.0000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11703870/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02196-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

The Hugo RAS system is characterized by its multimodular design, which leads to an increased docking effort. Exact data for docking time and the learning curve is missing. We describe for the first time the use of a laser-guided cart positioning to reduce the docking time. In this prospective monocentric study, the docking time was evalutated for a consecutive series of pelvic surgeries with the Hugo RAS system. In a subgroup, a cross-line laser was adapted at the cart for positioning using fix points at the ceiling. The medical personnel were classified as "inexperienced" with ≤ 5 consecutive dockings and as "experienced" with > 5 consecutive dockings. From 10/2023 to 08/2024, 82 procedures were performed with the Hugo RAS. For the evaluation 75 procedures could be considered. The mean docking time was 7.6 ± 3.5 min. There was a reduction in docking time from 13.5 ± 3.7 min in the first 5 procedures to 4.4 ± 0.9 min in the last 5 procedures (p < 0.001). Docking with laser (n = 45) was faster than without laser (n = 30) (6.2 ± 2.5 vs. 9.8 ± 3.7 min, p < 0.001). Faster docking time was observed with inexperienced surgical nursing staff with laser than without laser (10.4 ± 3.7 vs. 5.4 ± 1.4 min; p < 0.001). With experienced nursing staff, the laser had no influence (6.6 ± 1.3 vs. 6.7 ± 2.9 min; p = 0.9). As a reference docking time for daVinci Xi procedures was 2.4 ± 1.7 min (n = 5). Laser-guided cart positioning has a significant impact on docking time, especially for unexperienced medical personnel. Especially in the times of experienced staff shortage, laser-guided cart positioning can save operating time.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
激光辅助小车定位的使用大大减少了多模块机器人系统的对接时间。
Hugo RAS系统的特点是其多模块设计,增加了对接工作。对接时间和学习曲线的确切数据是缺失的。我们首次描述了使用激光引导小车定位,以减少对接时间。在这项前瞻性单中心研究中,使用Hugo RAS系统评估连续一系列盆腔手术的对接时间。在一个亚组中,在小车上使用交叉线激光器,利用天花板上的固定点进行定位。将医务人员分为经验不足(≤5次)和经验丰富(≤50次)两组。从2023年10月到2024年8月,使用Hugo RAS进行了82例手术。为了评价,可以考虑75种程序。平均对接时间为7.6±3.5分钟。对接时间从前5次的13.5±3.7分钟减少到后5次的4.4±0.9分钟(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.20
自引率
8.70%
发文量
145
期刊介绍: The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.
期刊最新文献
Colorectal cancer treatment assisted by robotic platforms - a systematic review. Predictors of persistent PSA after robot-assisted radical prostatectomy: a high-volume single-center experience. The importance of procedural indication in predicting operative time for elective robotic colon surgery. Learning curves of 13 surgeons for robot-assisted radical prostatectomy in a single institution: role of early case density. Comparison of clinical outcomes between TiRobot-assisted and conventional fluoroscopy-guided harms surgery for upper cervical fractures with atlantoaxial instability.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1