{"title":"Benefit of minimally invasive extracorporeal circulation on minimally invasive aortic valve replacement through right lateral mini-thoracotomy using femoral cannulation: a propensity-matched analysis.","authors":"Yoshitsugu Nakamura, Taisuke Nakayama, Kusumi Niitsuma, Yuka Higuma, Masaki Ushijima, Miho Kuroda, Yuto Yasumoto, Yujiro Ito, Yujiro Hayashi, Ryo Tsuruta, Naoya Yamauchi, Akihiro Higashino, Fumiaki Shikata","doi":"10.1093/icvts/ivae224","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objective of this study was to evaluate the impact of minimally invasive extracorporeal circulation on blood transfusion and asymptomatic brain injury in comparison to conventional extracorporeal circulation in the context of minimally invasive aortic valve replacement through right lateral mini-thoracotomy surgery.</p><p><strong>Methods: </strong>This was a retrospective observational study. Patients who underwent isolated aortic valve replacement through right lateral mini-thoracotomy surgery were divided into two groups: the minimally invasive extracorporeal circulation group and the conventional extracorporeal circulation group. Propensity matching was employed for further analysis.</p><p><strong>Results: </strong>Of 242 patients, the minimally invasive group and conventional group comprised 166 patients and 76 patients, respectively. In the matched cohort of 71 pairs, the two groups had similar preoperative characteristics. Extracorporeal circulation time was similar between the minimally invasive and conventional groups: 113 and 115 min, respectively, as was aortic clamp time: 86 and 82 min, respectively. Estimated amount of haemodilution was lower in the minimally invasive group (16.8 vs. 18.8%, P = 0.006). Blood transfusion frequency during surgery was less than half of conventional in the minimally invasive group (12.7 vs. 31.0%, P = 0.01). There were no deaths or stroke in either group during the hospital stay. Asymptomatic brain injury rate was the same for the two groups (35.2 vs. 35.2%, P = 1.00).</p><p><strong>Conclusions: </strong>Minimally invasive extracorporeal circulation was associated with fewer patients requiring transfusion than conventional extracorporeal circulation without an increase of asymptomatic brain injury in minimally invasive aortic valve replacement through right lateral mini-thoracotomy surgery.</p>","PeriodicalId":73406,"journal":{"name":"Interdisciplinary cardiovascular and thoracic surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11729723/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interdisciplinary cardiovascular and thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/icvts/ivae224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The objective of this study was to evaluate the impact of minimally invasive extracorporeal circulation on blood transfusion and asymptomatic brain injury in comparison to conventional extracorporeal circulation in the context of minimally invasive aortic valve replacement through right lateral mini-thoracotomy surgery.

Methods: This was a retrospective observational study. Patients who underwent isolated aortic valve replacement through right lateral mini-thoracotomy surgery were divided into two groups: the minimally invasive extracorporeal circulation group and the conventional extracorporeal circulation group. Propensity matching was employed for further analysis.

Results: Of 242 patients, the minimally invasive group and conventional group comprised 166 patients and 76 patients, respectively. In the matched cohort of 71 pairs, the two groups had similar preoperative characteristics. Extracorporeal circulation time was similar between the minimally invasive and conventional groups: 113 and 115 min, respectively, as was aortic clamp time: 86 and 82 min, respectively. Estimated amount of haemodilution was lower in the minimally invasive group (16.8 vs. 18.8%, P = 0.006). Blood transfusion frequency during surgery was less than half of conventional in the minimally invasive group (12.7 vs. 31.0%, P = 0.01). There were no deaths or stroke in either group during the hospital stay. Asymptomatic brain injury rate was the same for the two groups (35.2 vs. 35.2%, P = 1.00).

Conclusions: Minimally invasive extracorporeal circulation was associated with fewer patients requiring transfusion than conventional extracorporeal circulation without an increase of asymptomatic brain injury in minimally invasive aortic valve replacement through right lateral mini-thoracotomy surgery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微创体外循环对经右侧小开胸置管微创主动脉瓣置换术的益处:倾向匹配分析。
目的:本研究的目的是评估微创体外循环对输血和无症状脑损伤的影响,与传统体外循环相比,通过右侧小开胸手术微创主动脉瓣置换术。方法:回顾性观察性研究。通过右侧小开胸手术行孤立主动脉瓣置换术的患者分为微创体外循环组和常规体外循环组。进一步分析采用倾向匹配法。结果:242例患者中,微创组166例,常规组76例。在71对配对队列中,两组术前特征相似。微创组和常规组体外循环时间相似,分别为113 min和115 min,主动脉夹持时间分别为86 min和82 min。微创组估计血液稀释量较低(16.8% vs 18.8%, P = 0.006)。微创组术中输血次数少于常规组的一半(12.7% vs 31.0%, P = 0.01)。两组患者在住院期间均未发生死亡或中风。两组无症状脑损伤发生率相同(35.2% vs 35.2%, P = 1.00)。结论:微创体外循环与常规体外循环相比,需要输血的患者较少,且无症状脑损伤增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computational fluid dynamics to simulate stenotic lesions in coronary end-to-side anastomosis. Long-term retention of the pedicled thymic flap after bronchial stump coverage. Closure of ventricular septal defect in children with trisomy 18: perioperative events and long-term survival. Intraoperative aortic dissection in a patient with cervical aortic arch. Hyperacute silicosis after bronchoscopy-induced melanoptysis in a lung transplant patient. A first report in literature.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1