Death incidents following transcatheter edge-to-edge repair (TEER) with the MitraClip device: analysis of 10-years post-marketing death reports from the Manufacturer and User Facility Device Experience (MAUDE) registry.

IF 2 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS BMC Cardiovascular Disorders Pub Date : 2025-01-10 DOI:10.1186/s12872-025-04471-8
Xinghe Sun, Yifei Zhao, Yan Li
{"title":"Death incidents following transcatheter edge-to-edge repair (TEER) with the MitraClip device: analysis of 10-years post-marketing death reports from the Manufacturer and User Facility Device Experience (MAUDE) registry.","authors":"Xinghe Sun, Yifei Zhao, Yan Li","doi":"10.1186/s12872-025-04471-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.</p><p><strong>Methods: </strong>A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023. Duplicate reports and records from unrelated sources were excluded. The Cochran-Armitage test was performed to evaluate trends in the proportion of fatal events over time.</p><p><strong>Results: </strong>During the 10-year period following FDA approval, the MAUDE database recorded a total of 927 death reports and 9,211 injury reports associated with MitraClip. After excluding duplicates and irrelevant reports, 592 death cases were analyzed. The most commonly reported complications were MR (26.69%), tissue damage (24.16%), and hypotension (22.13%). The most frequent device-related issues were incomplete coaptation (14.70%), difficulty removing the divice (6.42%), and failure to adhere or bond/positioning failure(4.90%). Notably, 76.94% of deaths occurred within one year of implantation. The proportion of fatal events demonstrated a gradual decline, from 15.9% in 2014-2015 to 3.5% in 2020-2021 (p < 0.0001).</p><p><strong>Conclusions: </strong>This analysis of the MAUDE database indicates a gradual decline in the proportion of fatal events associated with MitraClip implantation, which may be attributed to growing operator experience and advancements in device design. Nonetheless, persistent focus is required on managing complications and addressing potential risks to further enhance device performance and optimize its clinical utility.</p>","PeriodicalId":9195,"journal":{"name":"BMC Cardiovascular Disorders","volume":"25 1","pages":"11"},"PeriodicalIF":2.0000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11721642/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Cardiovascular Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12872-025-04471-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.

Methods: A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023. Duplicate reports and records from unrelated sources were excluded. The Cochran-Armitage test was performed to evaluate trends in the proportion of fatal events over time.

Results: During the 10-year period following FDA approval, the MAUDE database recorded a total of 927 death reports and 9,211 injury reports associated with MitraClip. After excluding duplicates and irrelevant reports, 592 death cases were analyzed. The most commonly reported complications were MR (26.69%), tissue damage (24.16%), and hypotension (22.13%). The most frequent device-related issues were incomplete coaptation (14.70%), difficulty removing the divice (6.42%), and failure to adhere or bond/positioning failure(4.90%). Notably, 76.94% of deaths occurred within one year of implantation. The proportion of fatal events demonstrated a gradual decline, from 15.9% in 2014-2015 to 3.5% in 2020-2021 (p < 0.0001).

Conclusions: This analysis of the MAUDE database indicates a gradual decline in the proportion of fatal events associated with MitraClip implantation, which may be attributed to growing operator experience and advancements in device design. Nonetheless, persistent focus is required on managing complications and addressing potential risks to further enhance device performance and optimize its clinical utility.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Cardiovascular Disorders
BMC Cardiovascular Disorders CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.50
自引率
0.00%
发文量
480
审稿时长
1 months
期刊介绍: BMC Cardiovascular Disorders is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the heart and circulatory system, as well as related molecular and cell biology, genetics, pathophysiology, epidemiology, and controlled trials.
期刊最新文献
Prevalence of pulmonary hypertension and associated factors among rheumatic heart disease patients in Ethiopia. Prevalence and predictors of left atrial thrombus in patients with rheumatic atrial fibrillation undergoing cardiac surgery: a cross-sectional study. WATCHMAN versus LACbes® device for percutaneous left atrial appendage closure: a single-center, propensity-matched study. Bioinformatics analysis of ferroptosis-related hub genes and immunoinfiltration in myocardial ischemia/reperfusion following heart transplantation. Comparison of diaphragmatic breathing exercises and incentive spirometry on the functional status of heart failure patients: a randomized controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1