Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study.

IF 9.1 1区 医学 Q1 ANESTHESIOLOGY British journal of anaesthesia Pub Date : 2025-01-09 DOI:10.1016/j.bja.2024.09.033
Karine Brousseau, Leah Monette, Daniel I McIsaac, Christopher Wherrett, Ranjeeta Mallick, Aklile Workneh, Tim Ramsay, Alan Tinmouth, Julie Shaw, Justin Presseau, Julie Hallet, François M Carrier, Dean A Fergusson, Guillaume Martel
{"title":"Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study.","authors":"Karine Brousseau, Leah Monette, Daniel I McIsaac, Christopher Wherrett, Ranjeeta Mallick, Aklile Workneh, Tim Ramsay, Alan Tinmouth, Julie Shaw, Justin Presseau, Julie Hallet, François M Carrier, Dean A Fergusson, Guillaume Martel","doi":"10.1016/j.bja.2024.09.033","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Point-of-care testing devices to measure haemoglobin (Hgb) frequently inform transfusion decision-making in surgery. This study aimed to examine their accuracy in surgery, focusing on Hgb concentrations of 60-100 g L<sup>-1</sup>, a range with higher potential for transfusion.</p><p><strong>Methods: </strong>This was a prospective diagnostic cohort study focused on method comparison, conducted at two academic hospitals. Consecutive patients undergoing noncardiac surgery and requiring point-of-care Hgb measurements were eligible. Hgb concentrations from arterial and central venous blood samples were measured concurrently using three devices and compared with laboratory Hgb. The primary outcome was individual pairwise comparisons between point-of-care and laboratory Hgb values; agreement was determined based on a threshold of within 4 g L<sup>-1</sup>. The primary analysis consisted of computing limits of agreement.</p><p><strong>Results: </strong>A total of 1735 intraoperative blood samples were collected (1139 participants); 680 samples had a laboratory Hgb <100 g L<sup>-1</sup>. The limits of agreement among those with Hgb <100 g L<sup>-1</sup> were -9.5 to 8.0 g L<sup>-1</sup> for HemoCue®, -16.2 to 11.5 g L<sup>-1</sup> for i-STAT®, and -14.7 to 40.5 g L<sup>-1</sup> for Rad-67®. HemoCue was associated with a 5.8% incidence of potentially clinically significant transfusion error, whereas i-STAT and Rad-67 were associated with 25.3% and 28.2%, respectively. HemoCue yielded Hgb measurements within 10 g L<sup>-1</sup> in 98% of intraoperative blood samples.</p><p><strong>Conclusions: </strong>No point-of-care Hgb device demonstrated limits of agreement that were smaller than the agreement difference of 4 g L<sup>-1</sup>. Despite this, HemoCue can be safely used to inform transfusion decisions in surgery, given its error probability of <4% in transfusion scenarios.</p>","PeriodicalId":9250,"journal":{"name":"British journal of anaesthesia","volume":" ","pages":""},"PeriodicalIF":9.1000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of anaesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.bja.2024.09.033","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Point-of-care testing devices to measure haemoglobin (Hgb) frequently inform transfusion decision-making in surgery. This study aimed to examine their accuracy in surgery, focusing on Hgb concentrations of 60-100 g L-1, a range with higher potential for transfusion.

Methods: This was a prospective diagnostic cohort study focused on method comparison, conducted at two academic hospitals. Consecutive patients undergoing noncardiac surgery and requiring point-of-care Hgb measurements were eligible. Hgb concentrations from arterial and central venous blood samples were measured concurrently using three devices and compared with laboratory Hgb. The primary outcome was individual pairwise comparisons between point-of-care and laboratory Hgb values; agreement was determined based on a threshold of within 4 g L-1. The primary analysis consisted of computing limits of agreement.

Results: A total of 1735 intraoperative blood samples were collected (1139 participants); 680 samples had a laboratory Hgb <100 g L-1. The limits of agreement among those with Hgb <100 g L-1 were -9.5 to 8.0 g L-1 for HemoCue®, -16.2 to 11.5 g L-1 for i-STAT®, and -14.7 to 40.5 g L-1 for Rad-67®. HemoCue was associated with a 5.8% incidence of potentially clinically significant transfusion error, whereas i-STAT and Rad-67 were associated with 25.3% and 28.2%, respectively. HemoCue yielded Hgb measurements within 10 g L-1 in 98% of intraoperative blood samples.

Conclusions: No point-of-care Hgb device demonstrated limits of agreement that were smaller than the agreement difference of 4 g L-1. Despite this, HemoCue can be safely used to inform transfusion decisions in surgery, given its error probability of <4% in transfusion scenarios.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评价手术中即时血红蛋白测量的准确性(前提)和对输血实践的影响:一项前瞻性队列研究。
背景:用于测量血红蛋白(Hgb)的即时检测设备经常为外科输血决策提供信息。本研究旨在检验其在手术中的准确性,重点关注60-100 g L-1的Hgb浓度,这一范围具有较高的输血潜力。方法:这是一项前瞻性诊断队列研究,侧重于方法比较,在两所学术医院进行。连续接受非心脏手术并需要即时Hgb测量的患者符合条件。动脉和中心静脉血样本的Hgb浓度使用三种装置同时测量,并与实验室Hgb进行比较。主要结局是医疗点和实验室Hgb值之间的个体两两比较;一致性是基于4 g L-1以内的阈值确定的。初步分析包括计算一致限度。结果:共采集术中血液样本1735份(参与者1139名);680份样品具有实验室Hgb -1。Hgb -1患者的一致性限为HemoCue®的-9.5 ~ 8.0 g L-1, i-STAT®的-16.2 ~ 11.5 g L-1, Rad-67®的-14.7 ~ 40.5 g L-1。HemoCue与5.8%的潜在临床重大输血错误发生率相关,而i-STAT和Rad-67分别与25.3%和28.2%相关。HemoCue在98%的术中血液样本中获得了10 g L-1以内的Hgb测量值。结论:没有任何即食Hgb装置显示出的一致限度小于4 g L-1的一致差异。尽管如此,HemoCue可以安全地用于外科输血决策,因为它的错误概率为
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
13.50
自引率
7.10%
发文量
488
审稿时长
27 days
期刊介绍: The British Journal of Anaesthesia (BJA) is a prestigious publication that covers a wide range of topics in anaesthesia, critical care medicine, pain medicine, and perioperative medicine. It aims to disseminate high-impact original research, spanning fundamental, translational, and clinical sciences, as well as clinical practice, technology, education, and training. Additionally, the journal features review articles, notable case reports, correspondence, and special articles that appeal to a broader audience. The BJA is proudly associated with The Royal College of Anaesthetists, The College of Anaesthesiologists of Ireland, and The Hong Kong College of Anaesthesiologists. This partnership provides members of these esteemed institutions with access to not only the BJA but also its sister publication, BJA Education. It is essential to note that both journals maintain their editorial independence. Overall, the BJA offers a diverse and comprehensive platform for anaesthetists, critical care physicians, pain specialists, and perioperative medicine practitioners to contribute and stay updated with the latest advancements in their respective fields.
期刊最新文献
The number of central nervous system-driven symptoms predicts subsequent chronic primary pain: evidence from UK Biobank. The debate rages on: physician-assisted suicide in an ethical light. Response to Br J Anaesth 2024; 133: 1352-3. Two-person verbal check to confirm tracheal intubation: evaluation of practice changes to prevent unrecognised oesophageal intubation. Clinical team flow in the perioperative environment: a qualitative single-centre study. Continuous serratus anterior block for sternotomy analgesia after cardiac surgery: a single-centre feasibility study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1