How In Vivo Alteration of Hip Replacement Wear Mode Can Cause a Voluminous Inflammatory Reaction and an Excessive Titanium Exposure.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL Journal of Clinical Medicine Pub Date : 2025-01-02 DOI:10.3390/jcm14010210
Luca Sutter, Deborah J Hall, Lydia Bischoff, Corina Dommann-Scherrer, Michel Schläppi, Robin Pourzal, Nadim Hallab, Christoph Meier, Peter Wahl
{"title":"How In Vivo Alteration of Hip Replacement Wear Mode Can Cause a Voluminous Inflammatory Reaction and an Excessive Titanium Exposure.","authors":"Luca Sutter, Deborah J Hall, Lydia Bischoff, Corina Dommann-Scherrer, Michel Schläppi, Robin Pourzal, Nadim Hallab, Christoph Meier, Peter Wahl","doi":"10.3390/jcm14010210","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar. This case also is the first description of elimination kinetics of systemic titanium exposure caused by wear of a hip arthroplasty. <b>Methods:</b> Case report. <b>Results</b>: A 85-year-old male required revision after total hip arthroplasty due to aseptic loosening of the cup. A massive local adverse reaction to metal and polyethylene debris developed before revision, much larger than the implant damage would intuitively suggest. In this case, in vivo transition in wear mode from edge loading to impingement wear resulted in excessive titanium and polyethylene wear and subsequently a voluminous macrophage reaction and an excessive systemic titanium exposure, with blood concentrations showing a very long elimination half-life of more than two years. <b>Conclusions:</b> The volume of the wear particle reaction is dictated by the volume of the inflammatory cells, not of the wear particles. To the best of our knowledge, this is the first description of elimination kinetics in case of systemic titanium exposure. While the tissue response is caused by a sudden increase of titanium and polyethylene debris, titanium is detectable through whole blood, not serum, analysis and thus be an indicator for risk of failure due to abnormal articulation of the joint replacement. Such measurement may be useful if changes in implant position are detected radiographically. Major elevations of titanium concentrations may require revision, as for any other metal ions.</p>","PeriodicalId":15533,"journal":{"name":"Journal of Clinical Medicine","volume":"14 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11722162/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcm14010210","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar. This case also is the first description of elimination kinetics of systemic titanium exposure caused by wear of a hip arthroplasty. Methods: Case report. Results: A 85-year-old male required revision after total hip arthroplasty due to aseptic loosening of the cup. A massive local adverse reaction to metal and polyethylene debris developed before revision, much larger than the implant damage would intuitively suggest. In this case, in vivo transition in wear mode from edge loading to impingement wear resulted in excessive titanium and polyethylene wear and subsequently a voluminous macrophage reaction and an excessive systemic titanium exposure, with blood concentrations showing a very long elimination half-life of more than two years. Conclusions: The volume of the wear particle reaction is dictated by the volume of the inflammatory cells, not of the wear particles. To the best of our knowledge, this is the first description of elimination kinetics in case of systemic titanium exposure. While the tissue response is caused by a sudden increase of titanium and polyethylene debris, titanium is detectable through whole blood, not serum, analysis and thus be an indicator for risk of failure due to abnormal articulation of the joint replacement. Such measurement may be useful if changes in implant position are detected radiographically. Major elevations of titanium concentrations may require revision, as for any other metal ions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Clinical Medicine
Journal of Clinical Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
5.70
自引率
7.70%
发文量
6468
审稿时长
16.32 days
期刊介绍: Journal of Clinical Medicine (ISSN 2077-0383), is an international scientific open access journal, providing a platform for advances in health care/clinical practices, the study of direct observation of patients and general medical research. This multi-disciplinary journal is aimed at a wide audience of medical researchers and healthcare professionals. Unique features of this journal: manuscripts regarding original research and ideas will be particularly welcomed.JCM also accepts reviews, communications, and short notes. There is no limit to publication length: our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible.
期刊最新文献
Examining Cough's Role and Relief Strategies in Interstitial Lung Disease. A β-Thalassemia Cell Biobank: Updates, Further Validation in Genetic and Therapeutic Research and Opportunities During (and After) the COVID-19 Pandemic. Exploring the Relationship Between Continuously Monitored Vital Signs, Clinical Deterioration, and Clinical Actions. An Atypical Case of Rhabdomyolysis Following an Atypical Antidepressant Overdose. Removal of Spontaneously Fractured Leads with Their Proximal Ends in the Heart and Vasculature-Description of Different Approaches and Tools.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1