3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

IF 0.8 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS European Heart Journal: Case Reports Pub Date : 2024-12-23 eCollection Date: 2025-01-01 DOI:10.1093/ehjcr/ytae685
Mohamed Magdy, Maichel Botros, Mohammed Mostafa, Maro Gharbi, Arif Alnooryani
{"title":"3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.","authors":"Mohamed Magdy, Maichel Botros, Mohammed Mostafa, Maro Gharbi, Arif Alnooryani","doi":"10.1093/ehjcr/ytae685","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.</p><p><strong>Case summary: </strong>A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block. The patient underwent single-chamber permanent LP implantation. During the upgrade to a dual-chamber LP, 3D CT image fusion with fluoroscopy was utilized to accurately identify the ideal and safe implantation site for the device.</p><p><strong>Discussion: </strong>Integrating CT image guidance with fluoroscopy could enhance procedure safety, success rates, and reduces fluoroscopy time.</p>","PeriodicalId":11910,"journal":{"name":"European Heart Journal: Case Reports","volume":"9 1","pages":"ytae685"},"PeriodicalIF":0.8000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11718391/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal: Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block. The patient underwent single-chamber permanent LP implantation. During the upgrade to a dual-chamber LP, 3D CT image fusion with fluoroscopy was utilized to accurately identify the ideal and safe implantation site for the device.

Discussion: Integrating CT image guidance with fluoroscopy could enhance procedure safety, success rates, and reduces fluoroscopy time.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维计算机断层集成指导永久性Aveir AR无铅起搏器植入1例。
背景:单腔右心室无导联起搏器(LPs)的使用已得到广泛认可,右心房 LPs 的引入为双腔无导联起搏打开了大门。心脏计算机断层扫描(CT)分割集成可能会在手术过程中提供正确的视觉引导。病例摘要:一名 58 岁的男性患者因头晕和完全性心脏传导阻滞被送到急诊科。患者接受了单腔永久性 LP 植入术。在升级为双腔 LP 的过程中,利用三维 CT 图像融合透视技术准确确定了理想和安全的设备植入部位:讨论:将 CT 图像引导与透视相结合可提高手术安全性和成功率,并减少透视时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Heart Journal: Case Reports
European Heart Journal: Case Reports Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.30
自引率
10.00%
发文量
451
审稿时长
14 weeks
期刊最新文献
A multicomponent cardiac rehabilitation programme as a safe, feasible, and beneficial approach, including patients with left ventricular assist devices: a case report. Unmasking Brugada syndrome: a case report of diagnostic oversights. Crossed wires: a shocking case of an subcutaneous-ICD lead jailed by sternal wires. The catastrophe of catastrophic antiphospholipid syndrome: a case report. Twiddler's syndrome in extravascular implantable cardioverter-defibrillator: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1