Sant Kumar, Sandeep Jalli, Yader Sandoval, Khaldoon Alaswad, Nachiket J Patel, Tim Henry, Darshan Doshi, Ashish Pershad, Arnold Seto, Gautam Kumar, M Nicholas Burke, Emmanouil S Brilakis
{"title":"Systematic Review and Meta-Analysis of the Super High-Pressure Balloon (SIS-OPN) for Percutaneous Coronary Intervention.","authors":"Sant Kumar, Sandeep Jalli, Yader Sandoval, Khaldoon Alaswad, Nachiket J Patel, Tim Henry, Darshan Doshi, Ashish Pershad, Arnold Seto, Gautam Kumar, M Nicholas Burke, Emmanouil S Brilakis","doi":"10.1002/ccd.31403","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The super high-pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta-analysis of its efficacy and safety.</p><p><strong>Methods: </strong>A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI. Procedural success, major adverse cardiac events (MACE), coronary perforation, and other complications were pooled using weighted means, confidence intervals (CI), and I² statistics for heterogeneity assessment.</p><p><strong>Results: </strong>Twenty-nine studies (5 prospective including 2 randomized-controlled trials, 12 retrospective, and 12 case reports) were included in the systematic review, of which 11 (3 prospective, 8 retrospective) were included in the meta-analysis. Of the 1015 meta-analysis patients, 50.7% presented with stable angina and 21.6% with an acute coronary syndrome. Mean lesion length was 22.8 ± 13.7 mm, the prevalence of moderate or severe calcification was 93.7%, and 40.4% of lesions were in-stent. Procedural success was 95.1% (95% CI 89.3%-98.8% with significant heterogeneity: I² = 84.9%). The incidence of periprocedural MACE was 1.9% (95% CI 1.1%-2.8%, I² 86.9%), and the incidence of coronary perforation was 0.6% (95% CI 0.3%-1.5%, I² 87.2%).</p><p><strong>Conclusions: </strong>Use of the OPN NC balloon is associated with high success and acceptable complication rates. The heterogeneity of outcomes underscores the need for additional studies and standardized definitions.</p>","PeriodicalId":9650,"journal":{"name":"Catheterization and Cardiovascular Interventions","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and Cardiovascular Interventions","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ccd.31403","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The super high-pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta-analysis of its efficacy and safety.
Methods: A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI. Procedural success, major adverse cardiac events (MACE), coronary perforation, and other complications were pooled using weighted means, confidence intervals (CI), and I² statistics for heterogeneity assessment.
Results: Twenty-nine studies (5 prospective including 2 randomized-controlled trials, 12 retrospective, and 12 case reports) were included in the systematic review, of which 11 (3 prospective, 8 retrospective) were included in the meta-analysis. Of the 1015 meta-analysis patients, 50.7% presented with stable angina and 21.6% with an acute coronary syndrome. Mean lesion length was 22.8 ± 13.7 mm, the prevalence of moderate or severe calcification was 93.7%, and 40.4% of lesions were in-stent. Procedural success was 95.1% (95% CI 89.3%-98.8% with significant heterogeneity: I² = 84.9%). The incidence of periprocedural MACE was 1.9% (95% CI 1.1%-2.8%, I² 86.9%), and the incidence of coronary perforation was 0.6% (95% CI 0.3%-1.5%, I² 87.2%).
Conclusions: Use of the OPN NC balloon is associated with high success and acceptable complication rates. The heterogeneity of outcomes underscores the need for additional studies and standardized definitions.
期刊介绍:
Catheterization and Cardiovascular Interventions is an international journal covering the broad field of cardiovascular diseases. Subject material includes basic and clinical information that is derived from or related to invasive and interventional coronary or peripheral vascular techniques. The journal focuses on material that will be of immediate practical value to physicians providing patient care in the clinical laboratory setting. To accomplish this, the journal publishes Preliminary Reports and Work In Progress articles that complement the traditional Original Studies, Case Reports, and Comprehensive Reviews. Perspective and insight concerning controversial subjects and evolving technologies are provided regularly through Editorial Commentaries furnished by members of the Editorial Board and other experts. Articles are subject to double-blind peer review and complete editorial evaluation prior to any decision regarding acceptability.