Effect of a novel motion and simultaneous irrigation on the cyclic fatigue resistance of Hyflex EDM OneFile.

IF 1.9 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Odontology Pub Date : 2025-01-13 DOI:10.1007/s10266-024-01051-8
Giusy Rita Maria La Rosa, Pietro Lombardo, Luigi Generali, Eugenio Pedullà
{"title":"Effect of a novel motion and simultaneous irrigation on the cyclic fatigue resistance of Hyflex EDM OneFile.","authors":"Giusy Rita Maria La Rosa, Pietro Lombardo, Luigi Generali, Eugenio Pedullà","doi":"10.1007/s10266-024-01051-8","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to assess the cyclic fatigue resistance of a single-file system (i.e., Hyflex EDM OneFile), during continuous rotation and reflex dynamic motion with and without irrigation. Cyclic fatigue tests were conducted on 48 new Hyflex EDM One files using two different motions, with and without irrigation. The files were randomly assigned to four groups (n = 12) based on the tested motion and irrigation conditions: continuous rotation and the novel kinematics ReFlex Dynamic motion, with and without irrigation. The dynamic fatigue resistance was measured as the number of cycles to fracture (NCF) in an artificial zirconium canal with a 60° angle and a 5 mm radius of curvature at an intracanal temperature. The results were analyzed using the non-parametric Mann-Whitney test, with a significance level established at 5% (p < 0.05). The fractured instruments were examined with a scanning electron microscope. The instruments activated in continuous rotation, irrespective of irrigation conditions, demonstrated significantly higher NCF compared to those in ReFlex Dynamic (p < 0.05). Irrigation significantly impacted the cyclic fatigue resistance of Hyflex EDM in ReFlex Dynamic motion (p < 0.05), while it did not influence the resistance of files tested under continuous rotation (p > 0.05). Within the limitations of this in vitro study, HyFlex EDM One files tested under continuous rotation showed greater resistance to cyclic fatigue compared to those tested with ReFlex Dynamic motion, regardless of irrigation. Continuous hypochlorite irrigation enhanced the cyclic fatigue resistance only of the files tested in ReFlex Dynamic motion.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-024-01051-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to assess the cyclic fatigue resistance of a single-file system (i.e., Hyflex EDM OneFile), during continuous rotation and reflex dynamic motion with and without irrigation. Cyclic fatigue tests were conducted on 48 new Hyflex EDM One files using two different motions, with and without irrigation. The files were randomly assigned to four groups (n = 12) based on the tested motion and irrigation conditions: continuous rotation and the novel kinematics ReFlex Dynamic motion, with and without irrigation. The dynamic fatigue resistance was measured as the number of cycles to fracture (NCF) in an artificial zirconium canal with a 60° angle and a 5 mm radius of curvature at an intracanal temperature. The results were analyzed using the non-parametric Mann-Whitney test, with a significance level established at 5% (p < 0.05). The fractured instruments were examined with a scanning electron microscope. The instruments activated in continuous rotation, irrespective of irrigation conditions, demonstrated significantly higher NCF compared to those in ReFlex Dynamic (p < 0.05). Irrigation significantly impacted the cyclic fatigue resistance of Hyflex EDM in ReFlex Dynamic motion (p < 0.05), while it did not influence the resistance of files tested under continuous rotation (p > 0.05). Within the limitations of this in vitro study, HyFlex EDM One files tested under continuous rotation showed greater resistance to cyclic fatigue compared to those tested with ReFlex Dynamic motion, regardless of irrigation. Continuous hypochlorite irrigation enhanced the cyclic fatigue resistance only of the files tested in ReFlex Dynamic motion.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型运动和同步灌水对Hyflex EDM OneFile抗循环疲劳性能的影响。
本研究的目的是评估单锉系统(即Hyflex EDM OneFile)在连续旋转和反射动态运动中有无灌溉时的抗循环疲劳性。在48个新的Hyflex EDM One锉上进行了循环疲劳测试,使用两种不同的运动,有和没有灌溉。根据测试的运动和灌溉条件,将文件随机分为四组(n = 12):连续旋转和新型运动学反射动态运动,有和没有灌溉。在管内温度条件下,采用曲率半径为5mm、角度为60°的人工锆管测量其动态疲劳抗力。结果采用非参数Mann-Whitney检验进行分析,显著性水平为5% (p 0.05)。在体外研究的限制下,连续旋转测试的HyFlex EDM One锉比反射动态运动测试的锉具有更强的抗循环疲劳能力,无论是否灌溉。连续次氯酸盐灌溉仅提高了反射动态运动中测试的文件的抗循环疲劳能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
期刊最新文献
Serotype and distribution of adhesion genes in Streptococcus mutans isolated from people with Parkinson's disease. Comparison of the effectiveness of sodium-tri-metaphosphate-treated varnish containing eggshell and membrane powder and bioactıve glass varnish with fluoride varnish in preventing erosion: in vitro. Novel standardized method for inducing medication-related osteonecrosis of the jaw in rats and precise quantitative assessment of pathological outcomes. Association between apical periodontitis and brain inflammation: a systematic review from animals and human studies. Impact of demineralization, brushing, and remineralization sequences on dentin mineral retention and surface properties.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1