On Estimation of Zero-Sequence Impedances of Parallel Transmission Lines From Fault Data

IF 3.7 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Power Delivery Pub Date : 2025-01-20 DOI:10.1109/TPWRD.2025.3527738
Ahmad Salehi Dobakhshari;Sadegh Azizi
{"title":"On Estimation of Zero-Sequence Impedances of Parallel Transmission Lines From Fault Data","authors":"Ahmad Salehi Dobakhshari;Sadegh Azizi","doi":"10.1109/TPWRD.2025.3527738","DOIUrl":null,"url":null,"abstract":"The problem of estimating zero-sequence parameters of a parallel transmission line from fault data is considered. This paper analytically demonstrates that the zero-sequence impedances of a parallel transmission line are not, in general, attainable using the synchronized measurements taken at the line terminals following a ground fault on the line. To this end, Kirchhoff's voltage law (KVL) and current law (KCL) are employed to establish the system of equations that relate the measurements to the zero-sequence impedances of the line. The paper also highlights two rather theoretical exceptions to this generalization: first, the scenario of bolted faults, and second, situations where the fault resistance value is known beforehand (although this assumption is not valid in practice). A lemma is introduced and proved demonstrating that under specific conditions the zero-sequence reactances of the line can be accurately estimated while the zero-sequence resistances of the line remain unattainable. Simulation results, under a variety of conditions such as time-varying fault resistance and untransposed parallel lines, support the theoretical findings that zero-sequence resistances cannot be obtained from fault data while for short transposed lines or untransposed lines without earth wire zero-sequence reactances can be estimated quite accurately. Realistic measurement errors undermine the reliability of estimates, further questioning the attainability of zero-sequence parameters of parallel lines from fault data.","PeriodicalId":13498,"journal":{"name":"IEEE Transactions on Power Delivery","volume":"40 2","pages":"831-842"},"PeriodicalIF":3.7000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Delivery","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10847803/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The problem of estimating zero-sequence parameters of a parallel transmission line from fault data is considered. This paper analytically demonstrates that the zero-sequence impedances of a parallel transmission line are not, in general, attainable using the synchronized measurements taken at the line terminals following a ground fault on the line. To this end, Kirchhoff's voltage law (KVL) and current law (KCL) are employed to establish the system of equations that relate the measurements to the zero-sequence impedances of the line. The paper also highlights two rather theoretical exceptions to this generalization: first, the scenario of bolted faults, and second, situations where the fault resistance value is known beforehand (although this assumption is not valid in practice). A lemma is introduced and proved demonstrating that under specific conditions the zero-sequence reactances of the line can be accurately estimated while the zero-sequence resistances of the line remain unattainable. Simulation results, under a variety of conditions such as time-varying fault resistance and untransposed parallel lines, support the theoretical findings that zero-sequence resistances cannot be obtained from fault data while for short transposed lines or untransposed lines without earth wire zero-sequence reactances can be estimated quite accurately. Realistic measurement errors undermine the reliability of estimates, further questioning the attainability of zero-sequence parameters of parallel lines from fault data.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于故障数据的并联输电线路零序阻抗估计
研究了利用故障数据估计并联输电线路零序参数的问题。本文分析论证了并联传输线的零序阻抗,一般来说,在线路上发生接地故障后,使用在线路末端进行的同步测量是无法获得的。为此,基尔霍夫电压定律(KVL)和电流定律(KCL)被用来建立将测量值与线路零序阻抗联系起来的方程组。本文还强调了这种概括的两个相当理论上的例外情况:第一,螺栓故障的情况,第二,故障电阻值事先已知的情况(尽管这种假设在实践中无效)。引入并证明了一个引理,证明在特定条件下,线路的零序电抗可以准确估计,而线路的零序电阻仍然无法获得。在时变故障电阻和未转置平行线等多种条件下的仿真结果支持了从故障数据中无法获得零序电阻的理论发现,而对于短转置线路或未转置接地线的零序电抗可以比较准确地估计出来。实际测量误差破坏了估计的可靠性,进一步质疑从故障数据中获得平行线零序参数的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Power Delivery
IEEE Transactions on Power Delivery 工程技术-工程:电子与电气
CiteScore
9.00
自引率
13.60%
发文量
513
审稿时长
6 months
期刊介绍: The scope of the Society embraces planning, research, development, design, application, construction, installation and operation of apparatus, equipment, structures, materials and systems for the safe, reliable and economic generation, transmission, distribution, conversion, measurement and control of electric energy. It includes the developing of engineering standards, the providing of information and instruction to the public and to legislators, as well as technical scientific, literary, educational and other activities that contribute to the electric power discipline or utilize the techniques or products within this discipline.
期刊最新文献
Harmonic-Preserved Average-Value Model for Converters in Electromagnetic Transient Simulation Risk Assessment of Electrical Infrastructure Assets by a Multi-Objective Fine-Tuned Fuzzy Inference System Automated Inverter-Embedded Testing of Step-Up Transformers in Renewable Energy Systems To Capture Curtailed Renewable Energies in Smart Distribution Systems Using a Convex Co-Optimization of Dynamic Transformer Rating and Dynamic Reconfiguration Improved lumped-parameter thermal network modeling for rapid temperature rise evaluation of horizontal single-phase gas-insulated transmission lines considering distributed thermal convection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1