Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture.

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2025-01-17 DOI:10.1186/s12903-025-05434-3
Mai Hassan Diab, Medhat Sameh Abdelaziz, Mohamed Hatem Kamal Eldin
{"title":"Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture.","authors":"Mai Hassan Diab, Medhat Sameh Abdelaziz, Mohamed Hatem Kamal Eldin","doi":"10.1186/s12903-025-05434-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.</p><p><strong>Methods: </strong>A complete denture was constructed over a mandibular edentulous epoxy model. Two implants were inserted into the model between the laterals and canines following the prosthetically driven implant protocol. Locator retentive attachment inserts were digitally designed using free-form modeling software and milled from PEEK (Poly Ether Ether Ketone). After the pick-up of the ready- and custom-made retentive inserts, an insertion, removal, and masticatory cycles test simulating 1 year of patient usage was performed. The change in retention values was recorded at baseline, 6 months, and after one year of simulated clinical use. An independent sample t-test was used to compare the data between the two studied groups.</p><p><strong>Results: </strong>There were statistically significant differences in retention values between the custom-made and ready-made locator inserts at baseline and after 6 months. (p = 0.001*). On the other hand, there was no significant difference in retention after 1 year of simulated use. (p = 0.083, NS) CONCLUSIONS: The custom-made milled locator retentive attachment insert can be used as an alternative to the ready-made one due to their comparable retention values after 1 year of simulated use.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"92"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11742198/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05434-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.

Methods: A complete denture was constructed over a mandibular edentulous epoxy model. Two implants were inserted into the model between the laterals and canines following the prosthetically driven implant protocol. Locator retentive attachment inserts were digitally designed using free-form modeling software and milled from PEEK (Poly Ether Ether Ketone). After the pick-up of the ready- and custom-made retentive inserts, an insertion, removal, and masticatory cycles test simulating 1 year of patient usage was performed. The change in retention values was recorded at baseline, 6 months, and after one year of simulated clinical use. An independent sample t-test was used to compare the data between the two studied groups.

Results: There were statistically significant differences in retention values between the custom-made and ready-made locator inserts at baseline and after 6 months. (p = 0.001*). On the other hand, there was no significant difference in retention after 1 year of simulated use. (p = 0.083, NS) CONCLUSIONS: The custom-made milled locator retentive attachment insert can be used as an alternative to the ready-made one due to their comparable retention values after 1 year of simulated use.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CAD-CAM定位器固位体在下颌种植覆盖义齿中的固位。
背景:数字修复技术的不断发展使得附着体和固位插入体的定制成为可能,为定位覆盖义齿在日常实践中提供了一种简单、廉价的定期维护解决方案。本研究比较了完全数字化制造的定制定位器附着固定插入物与现成固定插入物在插入、移除和咀嚼周期后固位值的变化。方法:在下颌骨无牙环氧树脂模型上构建全口义齿。按照假体驱动的种植体方案,将两个种植体插入到模型的外侧和犬齿之间。使用自由形状建模软件对定位器固定附件进行数字化设计,并使用PEEK(聚醚醚酮)铣削。在取出现成的和定制的固位插入物后,进行模拟患者使用1年的插入、取出和咀嚼周期测试。在基线、6个月和模拟临床使用一年后记录保留值的变化。采用独立样本t检验比较两组数据。结果:定制定位器和现成定位器在基线和6个月后的固位值有统计学差异。(p = 0.001*)。另一方面,模拟使用1年后,保留率无显著差异。(p = 0.083, NS)结论:定制的铣削定位器固位附件在模拟使用1年后的固位值相当,可作为现成的固位附件的替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Comparison of biomechanical characteristics of the Schneiderian membrane with different transcrestal sinus floor elevation techniques using three-dimensional finite element analysis. Correction: D-mannose alleviates chronic periodontitis in rats by regulating the functions of neutrophils. Dental and oral health assessments in the German National Cohort (NAKO). Evaluation of the efficiency of smear layer removal during endodontic treatment using scanning electron microscopy: an in vitro study. Impacted lower third molar classification and difficulty index assessment: comparisons among dental students, general practitioners and deep learning model assistance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1