{"title":"Effect of the prolene ripcord suture on the baerveldt tube position: A case study.","authors":"Jia Y Ng, Chandni Nigam, Sameer Trikha, Avinash Kulkarni, Gerassimos Lascaratos","doi":"10.1177/11206721241310627","DOIUrl":null,"url":null,"abstract":"<p><p>A 42 year old Afro-Caribbean man underwent Baerveldt Glaucoma Implant (BGI) surgery for silicone oil induced glaucoma. Three months following initial surgery, the 3-0 prolene ripcord suture was removed. Anterior segment OCT demonstrates the position of the intracameral portion of the tube before and after the 3/0 prolene stent suture (PSS) removal. Ex-vivo experiments further demonstrate the variation in tube position using straight vs curved segments of 3/0, 4/0 and 5/0 PSS passed through the BGI lumen. Glaucoma tube surgeons should consider how the rigid nature of the prolene stent suture could influence the position of non-valved tubes within the eye, both during tube implantation and after prolene suture removal.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"11206721241310627"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241310627","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
A 42 year old Afro-Caribbean man underwent Baerveldt Glaucoma Implant (BGI) surgery for silicone oil induced glaucoma. Three months following initial surgery, the 3-0 prolene ripcord suture was removed. Anterior segment OCT demonstrates the position of the intracameral portion of the tube before and after the 3/0 prolene stent suture (PSS) removal. Ex-vivo experiments further demonstrate the variation in tube position using straight vs curved segments of 3/0, 4/0 and 5/0 PSS passed through the BGI lumen. Glaucoma tube surgeons should consider how the rigid nature of the prolene stent suture could influence the position of non-valved tubes within the eye, both during tube implantation and after prolene suture removal.
期刊介绍:
The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.