Wear investigation of implant-supported upper removable prothesis with electroplated gold or PEKK secondary crowns.

Annika Holtz, Manfred Grüner, Ludger Keilig, Christoph Bourauel, Helmut Stark, Istabrak Dörsam
{"title":"Wear investigation of implant-supported upper removable prothesis with electroplated gold or PEKK secondary crowns.","authors":"Annika Holtz, Manfred Grüner, Ludger Keilig, Christoph Bourauel, Helmut Stark, Istabrak Dörsam","doi":"10.1515/bmt-2024-0038","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of the present study was to investigate, whether polyetherketoneketone (PEKK) secondary crowns could be considered as alternative to gold standard in terms of their physical properties and manufacturing costs.</p><p><strong>Methods: </strong>An upper jaw model with six implants was used. Frameworks with either 6 PEKK- or 6 electroplated secondary crowns were cemented in a wear simulator. A total of 20 specimens (10 PEKK, 10 gold) run 10,000 cycles in the wear simulator with a lubricant. Additionally, 10,000 cycles in the thermocycling baths with 5 °C and 55 °C have gone through, before running extra 10,000 cycles in the wear simulator again. Finally, the abutments were analysed for signs of wear under the electron microscope.</p><p><strong>Results: </strong>The mean pulling out force value for PEKK was 21 N. For the electroplated gold secondary crowns an average of 19 N was measured. Multiple fluctuations were observed in the gold series of tests. After 20,000 cycles in the wear simulator and 10,000 cycles in the thermocycling machine, there were no major losses to be measured in terms of wear for both materials. In the microscopic analysis of the abutments, traces of wear could be seen in pull-out direction, mainly in the gold samples.</p><p><strong>Conclusions: </strong>PEKK secondary crowns have lower costs, more stable retention force values and are easier to produce than the gold standard. On average, the pull-out force values were 11 N higher than recommended.</p>","PeriodicalId":93905,"journal":{"name":"Biomedizinische Technik. Biomedical engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedizinische Technik. Biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/bmt-2024-0038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of the present study was to investigate, whether polyetherketoneketone (PEKK) secondary crowns could be considered as alternative to gold standard in terms of their physical properties and manufacturing costs.

Methods: An upper jaw model with six implants was used. Frameworks with either 6 PEKK- or 6 electroplated secondary crowns were cemented in a wear simulator. A total of 20 specimens (10 PEKK, 10 gold) run 10,000 cycles in the wear simulator with a lubricant. Additionally, 10,000 cycles in the thermocycling baths with 5 °C and 55 °C have gone through, before running extra 10,000 cycles in the wear simulator again. Finally, the abutments were analysed for signs of wear under the electron microscope.

Results: The mean pulling out force value for PEKK was 21 N. For the electroplated gold secondary crowns an average of 19 N was measured. Multiple fluctuations were observed in the gold series of tests. After 20,000 cycles in the wear simulator and 10,000 cycles in the thermocycling machine, there were no major losses to be measured in terms of wear for both materials. In the microscopic analysis of the abutments, traces of wear could be seen in pull-out direction, mainly in the gold samples.

Conclusions: PEKK secondary crowns have lower costs, more stable retention force values and are easier to produce than the gold standard. On average, the pull-out force values were 11 N higher than recommended.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电镀金或PEKK次冠种植体支持的上颌可拆卸假体的磨损研究。
目的:本研究的目的是探讨聚醚酮酮(PEKK)仲冠在物理性质和制造成本方面是否可以作为金标准的替代品。方法:采用6个种植体的上颌模型。框架与6 PEKK或6电镀二次冠在磨损模拟器中胶合。共有20个样品(10个PEKK, 10个gold)在润滑的磨损模拟器中运行10,000个循环。此外,在5 °C和55 °C的热循环浴中进行了10,000次循环,然后再次在磨损模拟器中进行了额外的10,000次循环。最后,在电子显微镜下分析了基台的磨损迹象。结果:PEKK的平均拔牙力值为21 N。电镀金二次冠的平均氮含量为19 。在金系列试验中观察到多次波动。在磨损模拟器中进行了2万次循环,在热循环机中进行了1万次循环后,两种材料的磨损都没有发生重大损失。在基台的显微分析中,可以看到沿拉出方向的磨损痕迹,主要出现在金样品中。结论:PEKK二次冠成本较低,固位力值稳定,且制作容易。平均拔出力值比推荐值高11 N。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Gesture recognition from surface electromyography signals based on the SE-DenseNet network. Wear investigation of implant-supported upper removable prothesis with electroplated gold or PEKK secondary crowns. Integration of neuromuscular control for multidirectional horizontal planar reaching movements in a portable upper limb exoskeleton for enhanced stroke rehabilitation. Empirical analysis on retinal segmentation using PSO-based thresholding in diabetic retinopathy grading. An exploratory study of pilot EEG features during the climb and descent phases of flight.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1