Adam Kositsky , Lauri Stenroth , Ervin Nippolainen , Jari Torniainen , Janne T.A. Mäkelä , Petri Paakkari , Tommi Paakkonen , Heikki Kröger , Juha Töyräs , Isaac O. Afara , Rami K. Korhonen
{"title":"The human patellar tendon is mechanically homogenous at its mid-substance","authors":"Adam Kositsky , Lauri Stenroth , Ervin Nippolainen , Jari Torniainen , Janne T.A. Mäkelä , Petri Paakkari , Tommi Paakkonen , Heikki Kröger , Juha Töyräs , Isaac O. Afara , Rami K. Korhonen","doi":"10.1016/j.jmbbm.2024.106875","DOIUrl":null,"url":null,"abstract":"<div><div>The human patellar tendon contains distinct fascicle bundles across its mediolateral and anteroposterior regions. Studies have suggested region-specific behaviour during <em>in vivo</em> actions, but it is unclear whether such regional differences result from localized variation in composition and mechanical properties within the tendon itself. Furthermore, the viscoelastic properties of any region of the human patellar tendon have not been well described previously. Here, a comprehensive investigation of the composition and material properties of six regions (three mediolateral × two anteroposterior) of the human patellar tendon was performed on tendons harvested from eight cadaver knees. Thorough viscoelastic (stress relaxation and sinusoidal) and elastic (failure) mechanical tests were conducted on dumbbell-shaped samples. Uronic acid (proteoglycan), hydroxyproline (collagen), and water contents were measured from the samples after mechanical testing. No systematic between-region differences were found for any measured biomechanical or biochemical parameter. However, the phase difference between stress and strain decreased as a function of increasing sinusoidal frequency (from 0.1 Hz to 5 Hz), suggesting the human patellar tendon behaves more elastically at higher strain rates. These results indicate the human patellar tendon is a homogenous material at its mid-substance and that other factors, such as geometrical constraints, enthesis properties, and insertion points, may be responsible for any region-specific behaviour <em>in vivo</em>. Additionally, the more elastic behaviour of the human patellar tendon as strain rate increases likely supports improved joint control and enhanced movement economy during fast actions such as sprinting.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"163 ","pages":"Article 106875"},"PeriodicalIF":3.3000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124005071","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The human patellar tendon contains distinct fascicle bundles across its mediolateral and anteroposterior regions. Studies have suggested region-specific behaviour during in vivo actions, but it is unclear whether such regional differences result from localized variation in composition and mechanical properties within the tendon itself. Furthermore, the viscoelastic properties of any region of the human patellar tendon have not been well described previously. Here, a comprehensive investigation of the composition and material properties of six regions (three mediolateral × two anteroposterior) of the human patellar tendon was performed on tendons harvested from eight cadaver knees. Thorough viscoelastic (stress relaxation and sinusoidal) and elastic (failure) mechanical tests were conducted on dumbbell-shaped samples. Uronic acid (proteoglycan), hydroxyproline (collagen), and water contents were measured from the samples after mechanical testing. No systematic between-region differences were found for any measured biomechanical or biochemical parameter. However, the phase difference between stress and strain decreased as a function of increasing sinusoidal frequency (from 0.1 Hz to 5 Hz), suggesting the human patellar tendon behaves more elastically at higher strain rates. These results indicate the human patellar tendon is a homogenous material at its mid-substance and that other factors, such as geometrical constraints, enthesis properties, and insertion points, may be responsible for any region-specific behaviour in vivo. Additionally, the more elastic behaviour of the human patellar tendon as strain rate increases likely supports improved joint control and enhanced movement economy during fast actions such as sprinting.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.