Effect of modeling liquid application on color stability and surface roughness of single-shade composites.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2025-01-23 DOI:10.1186/s12903-025-05502-8
Melek Güven Bekdaş, Ihsan Hubbezoglu
{"title":"Effect of modeling liquid application on color stability and surface roughness of single-shade composites.","authors":"Melek Güven Bekdaş, Ihsan Hubbezoglu","doi":"10.1186/s12903-025-05502-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objective of this study was to examine the effects of modeling liquid application on the color stability and surface roughness of single-shade composites.</p><p><strong>Materials and methods: </strong>Single-shade composites were divided into 4 main groups according to their contents. A total of 64 disc-shaped samples (8 × 2 mm) were prepared, 16 in each group, by using Teflon molds. The samples were divided into two subgroups on the basis of the application of a modeling liquid. After the initial color and roughness measurements, the samples were immersed in coffee for 12 days. Color changes were assessed via a spectrophotometer and ΔE values were calculated via the CIELAB formula. The surface roughness (Ra) was measured via a profilometer. The data were subjected to statistical analysis via two-way analysis of variance and Tukey's test to examine pairwise differences at a significance level of 0.05.</p><p><strong>Results: </strong>The application of modeling liquid reduced discoloration in Charisma Diamond One (CDO) and Vittra APS Unique (VUA), whereas it slightly increased discoloration in Omnichroma (OMN) and Zenchroma (ZNC). However, only the changes in CDO were statistically significant (p < 0.05). Among the composite control groups baseline and after the coloring procedures, the highest surface roughness degree was observed in the CDO group, while the lowest surface roughness degree was observed in the OMN and ZNC groups (p < 0.05), and the differences between them were found to be significant (p > 0.05). The surface roughness and color changes approached the mean values in the subgroups where the modeling liquid was applied, and there was no significant difference between them (p > 0.05). The application of modeling liquid was observed to reduce the variation in initial roughness among the composites, bringing their roughness values closer to an average range (0.26-0.34).</p><p><strong>Conclusion: </strong>Modeling liquid application increased roughness and discoloration in composites with initially low surface roughness (OMN and ZNC) while reducing roughness and discoloration in composites with initially high surface roughness (VUA and CDO).</p><p><strong>Clinical relevance: </strong>Modeling liquid application should be approached more cautiously in composites with high polishability, despite contributing to clinical use in composites with high roughness values.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"120"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11755945/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05502-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The objective of this study was to examine the effects of modeling liquid application on the color stability and surface roughness of single-shade composites.

Materials and methods: Single-shade composites were divided into 4 main groups according to their contents. A total of 64 disc-shaped samples (8 × 2 mm) were prepared, 16 in each group, by using Teflon molds. The samples were divided into two subgroups on the basis of the application of a modeling liquid. After the initial color and roughness measurements, the samples were immersed in coffee for 12 days. Color changes were assessed via a spectrophotometer and ΔE values were calculated via the CIELAB formula. The surface roughness (Ra) was measured via a profilometer. The data were subjected to statistical analysis via two-way analysis of variance and Tukey's test to examine pairwise differences at a significance level of 0.05.

Results: The application of modeling liquid reduced discoloration in Charisma Diamond One (CDO) and Vittra APS Unique (VUA), whereas it slightly increased discoloration in Omnichroma (OMN) and Zenchroma (ZNC). However, only the changes in CDO were statistically significant (p < 0.05). Among the composite control groups baseline and after the coloring procedures, the highest surface roughness degree was observed in the CDO group, while the lowest surface roughness degree was observed in the OMN and ZNC groups (p < 0.05), and the differences between them were found to be significant (p > 0.05). The surface roughness and color changes approached the mean values in the subgroups where the modeling liquid was applied, and there was no significant difference between them (p > 0.05). The application of modeling liquid was observed to reduce the variation in initial roughness among the composites, bringing their roughness values closer to an average range (0.26-0.34).

Conclusion: Modeling liquid application increased roughness and discoloration in composites with initially low surface roughness (OMN and ZNC) while reducing roughness and discoloration in composites with initially high surface roughness (VUA and CDO).

Clinical relevance: Modeling liquid application should be approached more cautiously in composites with high polishability, despite contributing to clinical use in composites with high roughness values.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
造型液对单色复合材料颜色稳定性和表面粗糙度的影响。
目的:本研究的目的是研究建模液的应用对单色复合材料的颜色稳定性和表面粗糙度的影响。材料与方法:将单色复合材料按其含量分为4大类。采用Teflon模具共制备64个8 × 2 mm的圆盘状样品,每组16个。根据模拟液的应用将样品分为两组。在最初的颜色和粗糙度测量之后,样品被浸泡在咖啡中12天。通过分光光度计评估颜色变化,并通过CIELAB公式计算ΔE值。表面粗糙度(Ra)通过轮廓仪测量。对数据进行统计学分析,采用双向方差分析和Tukey检验,两两差异检验,显著性水平为0.05。结果:造模液的应用降低了卡玛斯钻石一号(CDO)和Vittra APS Unique (VUA)的变色程度,而轻度增加了全彩色(OMN)和正色(ZNC)的变色程度。然而,只有CDO的变化有统计学意义(p 0.05)。表面粗糙度和颜色变化在应用建模液的亚组中接近平均值,两者之间无显著差异(p > 0.05)。模拟液的应用减少了复合材料初始粗糙度的差异,使其粗糙度值更接近于平均范围(0.26-0.34)。结论:模拟液的应用增加了初始表面粗糙度低的复合材料(OMN和ZNC)的粗糙度和变色,而降低了初始表面粗糙度高的复合材料(VUA和CDO)的粗糙度和变色。临床相关性:建模液体应用在具有高抛光性的复合材料中应该更加谨慎,尽管有助于临床使用具有高粗糙度值的复合材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Mesiobuccal root morphology influences biomechanical stability after endodontic microsurgery in maxillary first molars: a finite element analysis study. Pre-vascularized enhances therapeutic effects of human bone marrow-derived mesenchymal stem cell sheets in Buccal Mucosa wound. Effect of the number and localization of implants placed in the atrophic mandible on the fragility of the symphysis region. Development and application of a multidimensional instrument to evaluate competency discrepancies in orthodontic practice. Radiomics analysis of panoramic radiographs using machine learning for the detection of peri-implantitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1