Fracture resistances of heat-treated nickel-titanium files used for minimally invasive instrumentation.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2025-01-23 DOI:10.1186/s12903-025-05487-4
Yoo Jung Kang, Sang Won Kwak, Jung-Hong Ha, Gianluca Gambarini, Hyeon-Cheol Kim
{"title":"Fracture resistances of heat-treated nickel-titanium files used for minimally invasive instrumentation.","authors":"Yoo Jung Kang, Sang Won Kwak, Jung-Hong Ha, Gianluca Gambarini, Hyeon-Cheol Kim","doi":"10.1186/s12903-025-05487-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study compared the torsional resistance, bending stiffness, and cyclic fatigue resistances of different heat-treated NiTi files for minimally invasive instrumentation.</p><p><strong>Methods: </strong>TruNatomy (TN) and EndoRoad (ER) file systems were compared with ProTaper Gold (PG). Torsional load, distortion angle, and bending stiffness were assessed using a custom device AEndoS, and toughness was calculated using the torsional data. Cyclic fatigue resistance was evaluated using another custom device (EndoC) with 45-degree curved canal in which file was rotated until fracture using dynamic pecking motion at 37 °C. One-way analysis of variance and Duncan's post-hoc comparison were conducted at a significance level of 95%. Scanning electron microscopy (SEM) analyzed fracture features and differential scanning calorimetry (DSC) analyzed phase transformation temperatures.</p><p><strong>Results: </strong>ER and TN showed significantly lower torsional strength than PG (p < 0.05). However, ER showed a significantly greater distortion angle and the highest toughness, followed by PG and TN (p < 0.05). Both ER and TN showed similar bending stiffness, which was lower bending stiffness than PG (p < 0.05). ER showed the highest cyclic fatigue resistance (p < 0.05). SEM revealed typical fracture features across all groups, with distinct milling grooves in PG and TN, not in ER. DSC indicated that PG and ER showed a peak of austenite (Ap) at temperatures higher than body temperature, 42 °C and 40 °C, respectively, while TN showed A p at 25 °C.</p><p><strong>Conclusion: </strong>Files for minimally invasive instrumentations typically exhibited high cyclic fatigue resistance but showed differences in the properties. The selection should depend on the root canal and tooth condition.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"126"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11761776/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-05487-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study compared the torsional resistance, bending stiffness, and cyclic fatigue resistances of different heat-treated NiTi files for minimally invasive instrumentation.

Methods: TruNatomy (TN) and EndoRoad (ER) file systems were compared with ProTaper Gold (PG). Torsional load, distortion angle, and bending stiffness were assessed using a custom device AEndoS, and toughness was calculated using the torsional data. Cyclic fatigue resistance was evaluated using another custom device (EndoC) with 45-degree curved canal in which file was rotated until fracture using dynamic pecking motion at 37 °C. One-way analysis of variance and Duncan's post-hoc comparison were conducted at a significance level of 95%. Scanning electron microscopy (SEM) analyzed fracture features and differential scanning calorimetry (DSC) analyzed phase transformation temperatures.

Results: ER and TN showed significantly lower torsional strength than PG (p < 0.05). However, ER showed a significantly greater distortion angle and the highest toughness, followed by PG and TN (p < 0.05). Both ER and TN showed similar bending stiffness, which was lower bending stiffness than PG (p < 0.05). ER showed the highest cyclic fatigue resistance (p < 0.05). SEM revealed typical fracture features across all groups, with distinct milling grooves in PG and TN, not in ER. DSC indicated that PG and ER showed a peak of austenite (Ap) at temperatures higher than body temperature, 42 °C and 40 °C, respectively, while TN showed A p at 25 °C.

Conclusion: Files for minimally invasive instrumentations typically exhibited high cyclic fatigue resistance but showed differences in the properties. The selection should depend on the root canal and tooth condition.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于微创器械的热处理镍钛锉的抗断裂性能。
背景:本研究比较了不同热处理镍钛锉用于微创器械的抗扭性、弯曲刚度和循环疲劳性能。方法:将TruNatomy (TN)和endoload (ER)文件系统与ProTaper Gold (PG)文件系统进行比较。使用定制设备AEndoS评估扭转载荷、扭曲角度和弯曲刚度,并使用扭转数据计算韧性。使用另一种定制装置(EndoC)进行循环疲劳抗力评估,该装置具有45度弯曲管,在37°C下使用动态啄动运动旋转锉直到断裂。进行单因素方差分析和Duncan事后比较,显著性水平为95%。扫描电镜(SEM)分析了断口特征,差示扫描量热法(DSC)分析了相变温度。结果:ER和TN的扭转强度明显低于PG (p)。结论:微创器械用锉刀具有较高的抗循环疲劳性能,但在性能上存在差异。选择应根据根管和牙齿状况而定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
The effect of mandibular advancement with clear aligners compared with activator therapy on maxillary and mandibular volumes: a randomized controlled trial using CBCT. Evaluating the feasibility of calcium silicate-based sealers for strip perforation repair compared to mineral trioxide aggregate: an in-vitro study on bond strength. Body mass index, physical activity, and severe periodontitis- a cross-sectional study from the HUNT4 Oral Health Study. Complications of lower arch space maintainers in pediatric patients: a retrospective study. Survey on the usage and frequency of digital magnification devices in dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1