{"title":"Are different photogrammetry applications on smartphones sufficiently reliable?","authors":"Gülden Karabiber, Hanife Nuray Yılmaz, Gamze Yıldırım","doi":"10.4041/kjod24.134","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to compare the accuracy of Qlone, Magiscan, and 3dMD with that of direct anthropometry (DA).</p><p><strong>Methods: </strong>The study involved 41 patients. Sixteen facial landmarks, including six individual and five paired points, were marked on each participant's face. Subsequently, 18 linear measurements were assessed using a 3dMD device (multicamera photogrammetry), Qlone, Magiscan smartphone applications (single-camera photogrammetry), and DA. The Qlone and Magiscan images were calibrated using a reference point 10 mm from the nasion during DA to ensure a 1:1 correspondence.</p><p><strong>Results: </strong>Concerning the precision of the digital methods compared to DA, the mean intraclass correlation coefficient values of 3dMD, Qlone and Magiscan were 0.989, 0.980 and 0.982, respectively. Compared with DA, 3dMD achieved excellent trueness with the lowest average absolute differences in the measurements (highest value = 0.95 ± 0.62 mm). The highest values for Qlone and Magiscan were 1.51 ± 1.11 mm and 2.14 ± 1.69 mm, respectively. According to the number of parameters, the ranking of unreliable values (> 2 mm) was Magiscan (n = 46), Qlone (n = 35), and then, 3dMD (n = 4). Furthermore, reliability (less than 1 mm) was the highest for 3dMD (n = 517), followed by Magiscan (n = 457), and then, Qlone (n = 415).</p><p><strong>Conclusions: </strong>The 3dMD achieved excellent trueness with the lowest average absolute differences in the measurements. Based on statistical analysis, the trueness values of Magiscan and Qlone were close to that of 3dMD. To apply these smartphone applications clinically, more studies are necessary.</p>","PeriodicalId":51260,"journal":{"name":"Korean Journal of Orthodontics","volume":"55 1","pages":"37-47"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod24.134","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to compare the accuracy of Qlone, Magiscan, and 3dMD with that of direct anthropometry (DA).

Methods: The study involved 41 patients. Sixteen facial landmarks, including six individual and five paired points, were marked on each participant's face. Subsequently, 18 linear measurements were assessed using a 3dMD device (multicamera photogrammetry), Qlone, Magiscan smartphone applications (single-camera photogrammetry), and DA. The Qlone and Magiscan images were calibrated using a reference point 10 mm from the nasion during DA to ensure a 1:1 correspondence.

Results: Concerning the precision of the digital methods compared to DA, the mean intraclass correlation coefficient values of 3dMD, Qlone and Magiscan were 0.989, 0.980 and 0.982, respectively. Compared with DA, 3dMD achieved excellent trueness with the lowest average absolute differences in the measurements (highest value = 0.95 ± 0.62 mm). The highest values for Qlone and Magiscan were 1.51 ± 1.11 mm and 2.14 ± 1.69 mm, respectively. According to the number of parameters, the ranking of unreliable values (> 2 mm) was Magiscan (n = 46), Qlone (n = 35), and then, 3dMD (n = 4). Furthermore, reliability (less than 1 mm) was the highest for 3dMD (n = 517), followed by Magiscan (n = 457), and then, Qlone (n = 415).

Conclusions: The 3dMD achieved excellent trueness with the lowest average absolute differences in the measurements. Based on statistical analysis, the trueness values of Magiscan and Qlone were close to that of 3dMD. To apply these smartphone applications clinically, more studies are necessary.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.50
自引率
10.50%
发文量
48
审稿时长
>12 weeks
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
期刊最新文献
Are different photogrammetry applications on smartphones sufficiently reliable? Combined anterior and posterior miniscrews increase apical root resorption of maxillary incisors in protrusion and premolar extraction cases. Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysis. Evaluation of the effects of obesity on orthodontic tooth movement. Evaluation of the effects of the third molar on distalization and the effects of attachments on distalization and expansion with clear aligners: Three-dimensional finite element study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1