Practical Implications in Contemporary Dental Aesthetics-Shade Selection Assessment Using Intraoral Scanners.

IF 2.5 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Dentistry Journal Pub Date : 2025-01-20 DOI:10.3390/dj13010043
Alice Arina Ciocan Pendefunda, Cristina Gena Dascalu, Sebastian Bahrim, Cristina Iordache, Odette Luca, Magda-Ecaterina Antohe
{"title":"Practical Implications in Contemporary Dental Aesthetics-Shade Selection Assessment Using Intraoral Scanners.","authors":"Alice Arina Ciocan Pendefunda, Cristina Gena Dascalu, Sebastian Bahrim, Cristina Iordache, Odette Luca, Magda-Ecaterina Antohe","doi":"10.3390/dj13010043","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> Aesthetics is a challenging aspect to restore for both dentists and dental technicians. One of the characteristics of aesthetic restoration is the shade. The purpose of the study is to assess the accuracy of the shade selection feature of intraoral scanners (CEREC Omnican, 3Shape TRIOS) in comparison with an already established method-the VITA Easyshade V spectrophotometer (VE)-and test if there is any significant difference between the three devices. <b>Methods:</b> To conduct this in vitro study, the VITA Classical shade guide was used. The intraoral scanners would not be able to scan the VITA Classical as it is, hence, a study model (SM) was fabricated. To be able to test the accuracy of the intraoral scanners (IOSs) in detecting the dental color, a spectrophotometer had to be included in the study, as it was shown that it is the most accurate instrument for this purpose. Therefore, for the current study, the VITA Easyshade V spectrophotometer (VITA Zahnfabrik, Bad Sackingen, Germany) was selected. <b>Results:</b> The accuracy of the three devices when measuring the shade of the study model was calculated as a percentage. When comparing the primary results of the VE and the results obtained by the Omnicam and TRIOS, the latter is the most accurate (26.67%), whereas the other two scored 20%. The study also revealed the limitations of the instrumental devices that were used. <b>Conclusions:</b> First, both the VE and IOSs obtained unexpectedly low accuracy results. Possibly, the material VC is made of influenced the final accuracy values, but in practice, on a daily basis, dental materials represent a factor that cannot really be controlled.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 1","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763794/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13010043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: Aesthetics is a challenging aspect to restore for both dentists and dental technicians. One of the characteristics of aesthetic restoration is the shade. The purpose of the study is to assess the accuracy of the shade selection feature of intraoral scanners (CEREC Omnican, 3Shape TRIOS) in comparison with an already established method-the VITA Easyshade V spectrophotometer (VE)-and test if there is any significant difference between the three devices. Methods: To conduct this in vitro study, the VITA Classical shade guide was used. The intraoral scanners would not be able to scan the VITA Classical as it is, hence, a study model (SM) was fabricated. To be able to test the accuracy of the intraoral scanners (IOSs) in detecting the dental color, a spectrophotometer had to be included in the study, as it was shown that it is the most accurate instrument for this purpose. Therefore, for the current study, the VITA Easyshade V spectrophotometer (VITA Zahnfabrik, Bad Sackingen, Germany) was selected. Results: The accuracy of the three devices when measuring the shade of the study model was calculated as a percentage. When comparing the primary results of the VE and the results obtained by the Omnicam and TRIOS, the latter is the most accurate (26.67%), whereas the other two scored 20%. The study also revealed the limitations of the instrumental devices that were used. Conclusions: First, both the VE and IOSs obtained unexpectedly low accuracy results. Possibly, the material VC is made of influenced the final accuracy values, but in practice, on a daily basis, dental materials represent a factor that cannot really be controlled.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
期刊最新文献
Immediate Patient Satisfaction with Dental Esthetics After Endodontic and Prosthodontic Treatment of Dental Dyschromia. Practical Implications in Contemporary Dental Aesthetics-Shade Selection Assessment Using Intraoral Scanners. Clinical Outcomes and Complication Rates of Endodontically Treated Teeth with Fixed Dental Prostheses: A Retrospective Study. Does the Type of Resin Luting Material Affect the Bonding of CAD/CAM Materials to Dentin? The Influence of Posterior Class II Composite Restoration Location and Techniques on Marginal Sealing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1