Practical Implications in Contemporary Dental Aesthetics-Shade Selection Assessment Using Intraoral Scanners.

IF 3.1 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Dentistry Journal Pub Date : 2025-01-20 DOI:10.3390/dj13010043
Alice Arina Ciocan Pendefunda, Cristina Gena Dascalu, Sebastian Bahrim, Cristina Iordache, Odette Luca, Magda-Ecaterina Antohe
{"title":"Practical Implications in Contemporary Dental Aesthetics-Shade Selection Assessment Using Intraoral Scanners.","authors":"Alice Arina Ciocan Pendefunda, Cristina Gena Dascalu, Sebastian Bahrim, Cristina Iordache, Odette Luca, Magda-Ecaterina Antohe","doi":"10.3390/dj13010043","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> Aesthetics is a challenging aspect to restore for both dentists and dental technicians. One of the characteristics of aesthetic restoration is the shade. The purpose of the study is to assess the accuracy of the shade selection feature of intraoral scanners (CEREC Omnican, 3Shape TRIOS) in comparison with an already established method-the VITA Easyshade V spectrophotometer (VE)-and test if there is any significant difference between the three devices. <b>Methods:</b> To conduct this in vitro study, the VITA Classical shade guide was used. The intraoral scanners would not be able to scan the VITA Classical as it is, hence, a study model (SM) was fabricated. To be able to test the accuracy of the intraoral scanners (IOSs) in detecting the dental color, a spectrophotometer had to be included in the study, as it was shown that it is the most accurate instrument for this purpose. Therefore, for the current study, the VITA Easyshade V spectrophotometer (VITA Zahnfabrik, Bad Sackingen, Germany) was selected. <b>Results:</b> The accuracy of the three devices when measuring the shade of the study model was calculated as a percentage. When comparing the primary results of the VE and the results obtained by the Omnicam and TRIOS, the latter is the most accurate (26.67%), whereas the other two scored 20%. The study also revealed the limitations of the instrumental devices that were used. <b>Conclusions:</b> First, both the VE and IOSs obtained unexpectedly low accuracy results. Possibly, the material VC is made of influenced the final accuracy values, but in practice, on a daily basis, dental materials represent a factor that cannot really be controlled.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 1","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763794/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13010043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: Aesthetics is a challenging aspect to restore for both dentists and dental technicians. One of the characteristics of aesthetic restoration is the shade. The purpose of the study is to assess the accuracy of the shade selection feature of intraoral scanners (CEREC Omnican, 3Shape TRIOS) in comparison with an already established method-the VITA Easyshade V spectrophotometer (VE)-and test if there is any significant difference between the three devices. Methods: To conduct this in vitro study, the VITA Classical shade guide was used. The intraoral scanners would not be able to scan the VITA Classical as it is, hence, a study model (SM) was fabricated. To be able to test the accuracy of the intraoral scanners (IOSs) in detecting the dental color, a spectrophotometer had to be included in the study, as it was shown that it is the most accurate instrument for this purpose. Therefore, for the current study, the VITA Easyshade V spectrophotometer (VITA Zahnfabrik, Bad Sackingen, Germany) was selected. Results: The accuracy of the three devices when measuring the shade of the study model was calculated as a percentage. When comparing the primary results of the VE and the results obtained by the Omnicam and TRIOS, the latter is the most accurate (26.67%), whereas the other two scored 20%. The study also revealed the limitations of the instrumental devices that were used. Conclusions: First, both the VE and IOSs obtained unexpectedly low accuracy results. Possibly, the material VC is made of influenced the final accuracy values, but in practice, on a daily basis, dental materials represent a factor that cannot really be controlled.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
当代牙科美学的实际意义-使用口腔内扫描仪进行阴影选择评估。
背景/目的:美学是牙医和牙科技术人员修复的一个具有挑战性的方面。美学修复的特征之一是阴影。本研究的目的是评估口腔内扫描仪(CEREC Omnican, 3Shape TRIOS)与已建立的方法- VITA Easyshade V分光光度计(VE)的阴影选择特性的准确性,并测试三种设备之间是否存在显着差异。方法:采用VITA classic荫蔽指南进行体外研究。口腔内扫描仪无法扫描VITA classic,因此,制作了一个研究模型(SM)。为了能够测试口腔内扫描仪(ios)检测牙齿颜色的准确性,研究中必须包括分光光度计,因为它被证明是最准确的仪器。因此,本研究选择VITA Easyshade V分光光度计(VITA Zahnfabrik, Bad Sackingen, Germany)。结果:在测量研究模型的阴影时,三种装置的准确性以百分比计算。将VE的初步结果与Omnicam和TRIOS的结果进行比较,后者的准确率最高(26.67%),而其他两种方法的准确率为20%。该研究还揭示了所使用的仪器设备的局限性。结论:首先,VE和iss的准确率都出乎意料的低。制作VC的材料可能会影响最终的精度值,但在实践中,在日常生活中,牙科材料是一个无法真正控制的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
期刊最新文献
Dental Adhesion Protocol: A Clinically Oriented Literature Review with Practical Guidelines. Dental Amalgam and Oral Biological Responses: A Narrative Review of Current Evidence. Three-Dimensional Displacement Patterns in Maxillary Molar Distalization: A Comparative Finite Element Study. Clinical Outcomes and Complications of Dental Implants Placed and Restored by AEGD Residents: Up to 10-Year Retrospective Study. Partial Ceramic Veneers as a Conservative Restorative Strategy: A Narrative Review with Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1