Hong Li, Feifei Ma, Jinlong Weng, Yang DU, Binzhang Wu, Feng Sun
{"title":"[Accuracy of dynamic navigation system for immediate dental implant placement].","authors":"Hong Li, Feifei Ma, Jinlong Weng, Yang DU, Binzhang Wu, Feng Sun","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Dynamic navigation approaches are widely employed in the context of implant placement surgery. Implant surgery can be divided into immediate and delayed surgery according to the time of implantation. This retrospective study was developed to compare the accuracy of dynamic navigation system for immediate and delayed implantations.</p><p><strong>Methods: </strong>In the study, medical records from all patients that had undergone implant surgery between August 2019 and June 2021 in the First Clinical Division of the Peking University School and Hospital of Stomatology were retrospectively reviewed. There were 97 patients [53 males and 44 females, average age (47.14±11.99) years] and 97 implants (delayed group: 51; immediate group: 46) that met with study inclusion criteria and were included. Implant placement accuracy was measured by the superposition of the planned implant position in the preoperative cone beam computed tomography (CBCT) image and the actual implant position in the postoperative CBCT image. The 3-dimensional (3D) entry deviation (3D deviation in the coronal aspect of the alveolar ridge), 3D apex deviation (3D deviation in the apical area of the implant) and angular deviation were analyzed as the main observation index when comparing these two groups. The 2-dimensional (2D) horizontal deviation of the entry point and apex point, and the deviation of entry point depth and apex point depth were the secondary observation index.</p><p><strong>Results: </strong>The overall implant restoration survival rate was 100%, and no mechanical or biological complications were reported. The implantation success rate was 100%. The 3D entry deviation, 3D apex deviation and angular deviation of all analyzed implants were (1.146±0.458) mm, (1.276±0.526) mm, 3.022°±1.566°, respectively; while in the delayed group these respective values were (1.157±0.478) mm, (1.285±0.481) mm and 2.936°±1.470° as compared with (1.134±0.440) mm, (1.265±0.780) mm, 3.117°±1.677° in the immediate group. No significant differences (<i>P</i>=0.809, <i>P</i>=0.850, <i>P</i>=0.575) in accuracy were observed when comparing these two groups.</p><p><strong>Conclusion: </strong>Dynamic computer-assisted implant surgery system promotes accurate implantation, and both the immediate and delayed implantations exhibit similar levels of accuracy under dynamic navigation system that meets the clinical demands. Dynamic navigation system is feasible for immediate implantation.</p>","PeriodicalId":8790,"journal":{"name":"北京大学学报(医学版)","volume":"57 1","pages":"85-90"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11759790/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"北京大学学报(医学版)","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Dynamic navigation approaches are widely employed in the context of implant placement surgery. Implant surgery can be divided into immediate and delayed surgery according to the time of implantation. This retrospective study was developed to compare the accuracy of dynamic navigation system for immediate and delayed implantations.
Methods: In the study, medical records from all patients that had undergone implant surgery between August 2019 and June 2021 in the First Clinical Division of the Peking University School and Hospital of Stomatology were retrospectively reviewed. There were 97 patients [53 males and 44 females, average age (47.14±11.99) years] and 97 implants (delayed group: 51; immediate group: 46) that met with study inclusion criteria and were included. Implant placement accuracy was measured by the superposition of the planned implant position in the preoperative cone beam computed tomography (CBCT) image and the actual implant position in the postoperative CBCT image. The 3-dimensional (3D) entry deviation (3D deviation in the coronal aspect of the alveolar ridge), 3D apex deviation (3D deviation in the apical area of the implant) and angular deviation were analyzed as the main observation index when comparing these two groups. The 2-dimensional (2D) horizontal deviation of the entry point and apex point, and the deviation of entry point depth and apex point depth were the secondary observation index.
Results: The overall implant restoration survival rate was 100%, and no mechanical or biological complications were reported. The implantation success rate was 100%. The 3D entry deviation, 3D apex deviation and angular deviation of all analyzed implants were (1.146±0.458) mm, (1.276±0.526) mm, 3.022°±1.566°, respectively; while in the delayed group these respective values were (1.157±0.478) mm, (1.285±0.481) mm and 2.936°±1.470° as compared with (1.134±0.440) mm, (1.265±0.780) mm, 3.117°±1.677° in the immediate group. No significant differences (P=0.809, P=0.850, P=0.575) in accuracy were observed when comparing these two groups.
Conclusion: Dynamic computer-assisted implant surgery system promotes accurate implantation, and both the immediate and delayed implantations exhibit similar levels of accuracy under dynamic navigation system that meets the clinical demands. Dynamic navigation system is feasible for immediate implantation.
期刊介绍:
Beijing Da Xue Xue Bao Yi Xue Ban / Journal of Peking University (Health Sciences), established in 1959, is a national academic journal sponsored by Peking University, and its former name is Journal of Beijing Medical University. The coverage of the Journal includes basic medical sciences, clinical medicine, oral medicine, surgery, public health and epidemiology, pharmacology and pharmacy. Over the last few years, the Journal has published articles and reports covering major topics in the different special issues (e.g. research on disease genome, theory of drug withdrawal, mechanism and prevention of cardiovascular and cerebrovascular diseases, stomatology, orthopaedic, public health, urology and reproductive medicine). All the topics involve latest advances in medical sciences, hot topics in specific specialties, and prevention and treatment of major diseases.
The Journal has been indexed and abstracted by PubMed Central (PMC), MEDLINE/PubMed, EBSCO, Embase, Scopus, Chemical Abstracts (CA), Western Pacific Region Index Medicus (WPR), JSTChina, and almost all the Chinese sciences and technical index systems, including Chinese Science and Technology Paper Citation Database (CSTPCD), Chinese Science Citation Database (CSCD), China BioMedical Bibliographic Database (CBM), CMCI, Chinese Biological Abstracts, China National Academic Magazine Data-Base (CNKI), Wanfang Data (ChinaInfo), etc.