Zachary DeVries, Rashed AlAhmed, Ariane Parisien, Nicholas Nucci, Andrew Speirs, Kellen Walsh, J W Pollock, Katie McIlquham, Peter Lapner
{"title":"Eccentric Reaming is Superior to Augmented Components in B2 Glenoids: a Biomechanical study.","authors":"Zachary DeVries, Rashed AlAhmed, Ariane Parisien, Nicholas Nucci, Andrew Speirs, Kellen Walsh, J W Pollock, Katie McIlquham, Peter Lapner","doi":"10.1016/j.jse.2024.12.015","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Primary glenohumeral arthritis is typically associated with glenoid retroversion and posterior bone loss. Glenoid component fixation remains a weak link in the survivorship of anatomical total shoulder arthroplasty, particularly in the B2 glenoid. The aim of this study was to compare biomechanical properties of two glenoid preparation techniques in a B2 glenoid bone loss model.</p><p><strong>Methods: </strong>This was a biomechanical cyclic loading study. Thirty sawbone shoulder models were generated from a CT scan of a scapula with a B2 glenoid and 15<sup>o</sup> retroversion. The study consisted of two groups with 'low' correction (A groups), two groups with 'high' correction (B groups), and a control. Group A1 consisted of a 7<sup>0</sup> eccentric ream and a standard component; group A2 consisted of a 15<sup>o</sup> posteriorly augmented glenoid component (7<sup>0</sup> correction); group B1 consisted of a 12<sup>o</sup> anterior ream and standard component; group B2 used a 25<sup>o</sup> posteriorly augmented component (12<sup>o</sup> correction); group C (control) consisted of a standard component inserted in retroversion with no correction. Mechanical stability testing was performed through cyclic loading and resulting displacement was determined at 1, 10, 1000, 10,000, 50,000, and 100,00 cycles to assess for loosening.</p><p><strong>Results: </strong>A total of 26 samples were included in the analysis, all reaching 100,000 cycles. Displacement increased significantly from baseline to 100,000 cycles in all groups (p<0.05). At 100,000 cycles, the B1 group (1.4mm ±0.19) had significantly less displacement then the A2 (2.0mm ±0.29) and B2 (2.2mm ±0.49) (p=0.0.005) groups. There were no significant differences in translational forces between any of the groups at 100,000 cycles.</p><p><strong>Conclusions: </strong>Our data demonstrated that the use of higher-degree posteriorly augmented components resulted in statistically greater translational displacement over time compared with high-side reaming and use of a standard component. Further prospective clinical studies are needed to confirm these findings.</p>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jse.2024.12.015","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Primary glenohumeral arthritis is typically associated with glenoid retroversion and posterior bone loss. Glenoid component fixation remains a weak link in the survivorship of anatomical total shoulder arthroplasty, particularly in the B2 glenoid. The aim of this study was to compare biomechanical properties of two glenoid preparation techniques in a B2 glenoid bone loss model.
Methods: This was a biomechanical cyclic loading study. Thirty sawbone shoulder models were generated from a CT scan of a scapula with a B2 glenoid and 15o retroversion. The study consisted of two groups with 'low' correction (A groups), two groups with 'high' correction (B groups), and a control. Group A1 consisted of a 70 eccentric ream and a standard component; group A2 consisted of a 15o posteriorly augmented glenoid component (70 correction); group B1 consisted of a 12o anterior ream and standard component; group B2 used a 25o posteriorly augmented component (12o correction); group C (control) consisted of a standard component inserted in retroversion with no correction. Mechanical stability testing was performed through cyclic loading and resulting displacement was determined at 1, 10, 1000, 10,000, 50,000, and 100,00 cycles to assess for loosening.
Results: A total of 26 samples were included in the analysis, all reaching 100,000 cycles. Displacement increased significantly from baseline to 100,000 cycles in all groups (p<0.05). At 100,000 cycles, the B1 group (1.4mm ±0.19) had significantly less displacement then the A2 (2.0mm ±0.29) and B2 (2.2mm ±0.49) (p=0.0.005) groups. There were no significant differences in translational forces between any of the groups at 100,000 cycles.
Conclusions: Our data demonstrated that the use of higher-degree posteriorly augmented components resulted in statistically greater translational displacement over time compared with high-side reaming and use of a standard component. Further prospective clinical studies are needed to confirm these findings.
期刊介绍:
The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.