Evaluation of Accuracy and Safety of the 365-Day Implantable Eversense Continuous Glucose Monitoring System: The ENHANCE Study.

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2025-01-27 DOI:10.1089/dia.2024.0592
Timothy S Bailey, David R Liljenquist, Douglas S Denham, Ronald L Brazg, Sorin Ioacara, James Masciotti, Samanwoy Ghosh-Dastidar, Katherine S Tweden, Francine R Kaufman
{"title":"Evaluation of Accuracy and Safety of the 365-Day Implantable Eversense Continuous Glucose Monitoring System: The ENHANCE Study.","authors":"Timothy S Bailey, David R Liljenquist, Douglas S Denham, Ronald L Brazg, Sorin Ioacara, James Masciotti, Samanwoy Ghosh-Dastidar, Katherine S Tweden, Francine R Kaufman","doi":"10.1089/dia.2024.0592","DOIUrl":null,"url":null,"abstract":"<p><p>The implanted Eversense Continuous Glucose Monitoring (CGM) System transitioned from 90- to 180- to 365-day durations marketed today. This report summarizes the 365-day clinical study. ENHANCE was a prospective, multicenter study evaluating the accuracy and safety of the Eversense 365 CGM system through 1 year in adults with diabetes. Accuracy and adverse events (AEs) were assessed during 14 in-clinic visits comparing CGM and Yellow Springs Instrument reference glucose measurements, including during hyperglycemia and hypoglycemia challenges. In total, 110 participants were implanted with the Eversense 365 CGM System. The overall mean absolute relative difference was 8.8% with primarily one calibration per week. The confirmed alert detection rate at 70 mg/dL was 96.6%, and at 180 mg/dL, it was 97.9%. Ninety percent of the sensors survived 365 days. Interoperable CGM special controls were met. No related serious AEs were reported. The Eversense 365 CGM was shown to be safe and accurate through 1 year with primarily one calibration per week.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0592","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

The implanted Eversense Continuous Glucose Monitoring (CGM) System transitioned from 90- to 180- to 365-day durations marketed today. This report summarizes the 365-day clinical study. ENHANCE was a prospective, multicenter study evaluating the accuracy and safety of the Eversense 365 CGM system through 1 year in adults with diabetes. Accuracy and adverse events (AEs) were assessed during 14 in-clinic visits comparing CGM and Yellow Springs Instrument reference glucose measurements, including during hyperglycemia and hypoglycemia challenges. In total, 110 participants were implanted with the Eversense 365 CGM System. The overall mean absolute relative difference was 8.8% with primarily one calibration per week. The confirmed alert detection rate at 70 mg/dL was 96.6%, and at 180 mg/dL, it was 97.9%. Ninety percent of the sensors survived 365 days. Interoperable CGM special controls were met. No related serious AEs were reported. The Eversense 365 CGM was shown to be safe and accurate through 1 year with primarily one calibration per week.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估 365 天植入式 Eversense 连续血糖监测系统的准确性和安全性:ENHANCE 研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
Clinical Utility of Serum C-Peptide Concentration for Hospitalized Patients with Hyperglycemia. Glycemic Variability and Disordered Eating Among Adolescents and Young Adults with Type 1 Diabetes: The Role of Disinhibited Eating. GLP-1 Receptor Agonist Therapy in Cystic Fibrosis-Related Diabetes: A Case Report. Insulin Pump Use and Diabetic Ketoacidosis Risk in Type 1 Diabetes: Secular Trends over Four Decades. The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1