Randomized comparison of the combined Sirolimus eluting and endothelial progenitor cell combo Stent vs. biolimus eluting absorbable polymer coated biomatrix alpha stent in patients undergoing percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for randomized trials with clinical outcome (SORT OUT) XI trial
Ashkan Eftekhari MD PhD , Evald Høj Christiansen MD PhD , Jens Flensted Lassen MD PhD , Bent Raungaard MD PhD , Lars Jakobsen MD PhD , Lisette Okkels Jensen MD DMSci PhD
{"title":"Randomized comparison of the combined Sirolimus eluting and endothelial progenitor cell combo Stent vs. biolimus eluting absorbable polymer coated biomatrix alpha stent in patients undergoing percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for randomized trials with clinical outcome (SORT OUT) XI trial","authors":"Ashkan Eftekhari MD PhD , Evald Høj Christiansen MD PhD , Jens Flensted Lassen MD PhD , Bent Raungaard MD PhD , Lars Jakobsen MD PhD , Lisette Okkels Jensen MD DMSci PhD","doi":"10.1016/j.ahj.2025.01.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Rationale</h3><div>The biodegradable polymer Biomatrix Alpha stent contains biolimus A9 drug which is a sirolimus derivative increased in lipophicity. The biodegradable polymer sirolimus eluting Combo stent is a dual-therapy sirolimus-eluting and CD34+ antibody coated stent capturing endothelial progenitor cells (EPCs).</div></div><div><h3>Hypothesis</h3><div>The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 Biomatrix Alpha stent is noninferior to the biodegradable polymer sirolimus eluting Combo stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).</div></div><div><h3>Methods</h3><div>The SORT OUT XI study was a randomized, multicenter, single blinded, all-comer, 2-arm, noninferiority trial comparing the biodegradable polymer biolimus A9 Biomatrix Alpha stent to the biodegradable polymer sirolimus eluting Combo stent in 3 Danish University Hospitals in Western Denmark. The composite primary endpoint was target lesion failure (TLF) within 12 months. TLF was defined as composite of cardiac death, myocardial infarction not related to other than index lesion or target lesion revascularization. Clinically driven event detection was used and no planned follow up was performed. With a sample size of 1,564 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level had a 90% power to detect noninferiority with a predetermined noninferiority margin of 2.1%.</div></div><div><h3>Results</h3><div>The trial ran from August 14, 2019 to March 19, 2023. A total of 3141 patients were enrolled and randomized 1:1 to Combo stent (n = 1,573) and Biomatrix Alpha stent (n = 1,568).</div></div><div><h3>Conclusion</h3><div>The SORT OUT XI trial will assess if the biolimus A9 eluting Biomatrix Alpha stent is noninferior to the dual-therapy Combo stent with respect to target lesion failure.</div></div><div><h3>ClinicalTrials.gov</h3><div>NCT03952273.</div></div>","PeriodicalId":7868,"journal":{"name":"American heart journal","volume":"283 ","pages":"Pages 37-42"},"PeriodicalIF":3.7000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American heart journal","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0002870325000134","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Rationale
The biodegradable polymer Biomatrix Alpha stent contains biolimus A9 drug which is a sirolimus derivative increased in lipophicity. The biodegradable polymer sirolimus eluting Combo stent is a dual-therapy sirolimus-eluting and CD34+ antibody coated stent capturing endothelial progenitor cells (EPCs).
Hypothesis
The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 Biomatrix Alpha stent is noninferior to the biodegradable polymer sirolimus eluting Combo stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).
Methods
The SORT OUT XI study was a randomized, multicenter, single blinded, all-comer, 2-arm, noninferiority trial comparing the biodegradable polymer biolimus A9 Biomatrix Alpha stent to the biodegradable polymer sirolimus eluting Combo stent in 3 Danish University Hospitals in Western Denmark. The composite primary endpoint was target lesion failure (TLF) within 12 months. TLF was defined as composite of cardiac death, myocardial infarction not related to other than index lesion or target lesion revascularization. Clinically driven event detection was used and no planned follow up was performed. With a sample size of 1,564 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level had a 90% power to detect noninferiority with a predetermined noninferiority margin of 2.1%.
Results
The trial ran from August 14, 2019 to March 19, 2023. A total of 3141 patients were enrolled and randomized 1:1 to Combo stent (n = 1,573) and Biomatrix Alpha stent (n = 1,568).
Conclusion
The SORT OUT XI trial will assess if the biolimus A9 eluting Biomatrix Alpha stent is noninferior to the dual-therapy Combo stent with respect to target lesion failure.
期刊介绍:
The American Heart Journal will consider for publication suitable articles on topics pertaining to the broad discipline of cardiovascular disease. Our goal is to provide the reader primary investigation, scholarly review, and opinion concerning the practice of cardiovascular medicine. We especially encourage submission of 3 types of reports that are not frequently seen in cardiovascular journals: negative clinical studies, reports on study designs, and studies involving the organization of medical care. The Journal does not accept individual case reports or original articles involving bench laboratory or animal research.