{"title":"Interface Pressures Derived from a Calibrated Bandage Applied for Compression Therapy.","authors":"Kotaro Suehiro, Hitoshi Sakuda, Takasuke Harada, Yuriko Takeuchi, Takahiro Mizoguchi, Ryunosuke Sakamoto, Hiroshi Kurazumi, Ryo Suzuki, Kimikazu Hamano","doi":"10.3400/avd.oa.24-00103","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> We sought to clarify the interface pressure (IP) and its variation by applying Biflex16, a calibrated bandage, to the lower leg. <b>Methods:</b> In Study I, 50 participants applied a bandage to the lower leg of a single subject in two ways: first, with 50% overlap, while the calibration rectangle became a square (Application 1), and then with 50% overlap without intentional stretch (Application 2) which served as a control. In Study II, another 51 participants applied the bandage to their lower leg via Application 1. The IP was measured at the level of the transposition of the medial gastrocnemius muscle into the Achilles tendon (B1). <b>Results:</b> In Study I, the median IP (37 mmHg) and interquartile range (IQR; 9 mmHg) in the standing position were the same for Applications 1 and 2. In Study II, the obtained IP and IQR values were 38 and 12 mmHg, respectively, in the sitting position. This IP was similar to that obtained in Study I, and no correlation was found between IP and leg circumference. <b>Conclusions:</b> The variation in the IP obtained by the calibrated bandage was reasonably small when applied via Application 1. The obtained IPs did not correlate with the leg circumference.</p>","PeriodicalId":7995,"journal":{"name":"Annals of vascular diseases","volume":"18 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11771149/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of vascular diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3400/avd.oa.24-00103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: We sought to clarify the interface pressure (IP) and its variation by applying Biflex16, a calibrated bandage, to the lower leg. Methods: In Study I, 50 participants applied a bandage to the lower leg of a single subject in two ways: first, with 50% overlap, while the calibration rectangle became a square (Application 1), and then with 50% overlap without intentional stretch (Application 2) which served as a control. In Study II, another 51 participants applied the bandage to their lower leg via Application 1. The IP was measured at the level of the transposition of the medial gastrocnemius muscle into the Achilles tendon (B1). Results: In Study I, the median IP (37 mmHg) and interquartile range (IQR; 9 mmHg) in the standing position were the same for Applications 1 and 2. In Study II, the obtained IP and IQR values were 38 and 12 mmHg, respectively, in the sitting position. This IP was similar to that obtained in Study I, and no correlation was found between IP and leg circumference. Conclusions: The variation in the IP obtained by the calibrated bandage was reasonably small when applied via Application 1. The obtained IPs did not correlate with the leg circumference.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of vascular diseases
Annals of vascular diseases PERIPHERAL VASCULAR DISEASE-
自引率
0.00%
发文量
41
期刊最新文献
A Multifaceted Approach to Abdominal Aortic Aneurysm. Abdominal Aortic Aneurysm with Primary Cold Agglutinin Disease Treated with Endovascular Aortic Repair. Brachial-Ankle Pulse Wave Velocity Reflects Regional Arterial Stiffness and Distensibility in Patients with Abdominal Aortic Aneurysm. Clinical Outcomes after Revascularization in Patients with Chronic Limb-Threatening Ischemia. Interface Pressures Derived from a Calibrated Bandage Applied for Compression Therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1