Small changes of femoral torsion in varus or valgus distal femoral osteotomy using patient-specific instruments.

IF 2.6 3区 医学 Q2 ORTHOPEDICS International Orthopaedics Pub Date : 2025-03-01 Epub Date: 2025-01-29 DOI:10.1007/s00264-025-06415-5
Lukas Jud, Georgios Neopoulos, Sandro Hodel, Lazaros Vlachopoulos, Sandro F Fucentese
{"title":"Small changes of femoral torsion in varus or valgus distal femoral osteotomy using patient-specific instruments.","authors":"Lukas Jud, Georgios Neopoulos, Sandro Hodel, Lazaros Vlachopoulos, Sandro F Fucentese","doi":"10.1007/s00264-025-06415-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Hinge fractures show a relatively high incidence in varus and valgus distal femoral osteotomy (DFO) and can lead to delayed- or non-union. Another observed complication of a hinge fracture is an unintentional change of the postoperative femoral torsion of up to + 9.5° in conventionally performed DFO. We hypothesize that the change of femoral torsion in case of a hinge fracture is less pronounced when DFO is performed using patient-specific instruments (PSI) compared to the literature of conventionally performed DFO.</p><p><strong>Methods: </strong>All patients who underwent varus or valgus DFO using PSI from January 2014 to September 2023 were included. Radiographs and computed tomography (CT) scans were used to screen for hinge fractures. Pre- and postoperative femoral torsion was measured in CT.</p><p><strong>Results: </strong>Thirty-five medial closing-wedge DFO (MCW-DFO), 27 lateral closing-wedge DFO (LCW-DFO), and 27 lateral opening-wedge DFO (LOW-DFO) were included, resulting in a total of 89 included osteotomies. A total of 55 hinge fractures (61.8%) were observed. The femoral torsion changed significantly from 20.5° ± 7.7° to 15.5° ± 8.1° (p < 0.001) in LOW-DFO with a hinge fracture, whereas the other two techniques showed no significant change of femoral torsion.</p><p><strong>Conclusion: </strong>The use of PSI in varus and valgus DFO showed only small changes of the postoperative femoral torsion, even in case of a hinge fracture. The change of femoral torsion was depending on the type of DFO and was only significant in LOW-DFO, however, not exceeding a mean change of 5°.</p>","PeriodicalId":14450,"journal":{"name":"International Orthopaedics","volume":" ","pages":"621-627"},"PeriodicalIF":2.6000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11889048/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00264-025-06415-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Hinge fractures show a relatively high incidence in varus and valgus distal femoral osteotomy (DFO) and can lead to delayed- or non-union. Another observed complication of a hinge fracture is an unintentional change of the postoperative femoral torsion of up to + 9.5° in conventionally performed DFO. We hypothesize that the change of femoral torsion in case of a hinge fracture is less pronounced when DFO is performed using patient-specific instruments (PSI) compared to the literature of conventionally performed DFO.

Methods: All patients who underwent varus or valgus DFO using PSI from January 2014 to September 2023 were included. Radiographs and computed tomography (CT) scans were used to screen for hinge fractures. Pre- and postoperative femoral torsion was measured in CT.

Results: Thirty-five medial closing-wedge DFO (MCW-DFO), 27 lateral closing-wedge DFO (LCW-DFO), and 27 lateral opening-wedge DFO (LOW-DFO) were included, resulting in a total of 89 included osteotomies. A total of 55 hinge fractures (61.8%) were observed. The femoral torsion changed significantly from 20.5° ± 7.7° to 15.5° ± 8.1° (p < 0.001) in LOW-DFO with a hinge fracture, whereas the other two techniques showed no significant change of femoral torsion.

Conclusion: The use of PSI in varus and valgus DFO showed only small changes of the postoperative femoral torsion, even in case of a hinge fracture. The change of femoral torsion was depending on the type of DFO and was only significant in LOW-DFO, however, not exceeding a mean change of 5°.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
股骨远端内翻或外翻截骨术中股骨扭转的微小变化。
目的:股骨远端截骨术(DFO)内翻和外翻中铰链骨折的发生率相对较高,并可导致延迟愈合或不愈合。另一个观察到的铰链骨折并发症是,在常规DFO中,术后股骨扭转的意外变化可达+ 9.5°。我们假设在铰链骨折的情况下,与传统的DFO相比,使用患者专用器械(PSI)进行DFO时,股骨扭转的变化不那么明显。方法:纳入2014年1月至2023年9月所有使用PSI进行内翻或外翻DFO的患者。x线片和计算机断层扫描(CT)用于筛查铰链骨折。术前和术后用CT测量股骨扭转。结果:纳入35例内侧闭合楔形DFO (MCW-DFO), 27例外侧闭合楔形DFO (LCW-DFO), 27例外侧开口楔形DFO (LOW-DFO),共89例纳入截骨术。共观察到铰链骨折55例(61.8%)。股骨扭转从20.5°±7.7°到15.5°±8.1°变化明显(p结论:PSI在内翻和外翻DFO中使用,即使在铰链骨折的情况下,术后股骨扭转也只有很小的变化。股骨扭转的变化取决于DFO的类型,仅在LOW-DFO中显著,但不超过5°的平均变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Orthopaedics
International Orthopaedics 医学-整形外科
CiteScore
5.50
自引率
7.40%
发文量
360
审稿时长
1 months
期刊介绍: International Orthopaedics, the Official Journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT) , publishes original papers from all over the world. The articles deal with clinical orthopaedic surgery or basic research directly connected with orthopaedic surgery. International Orthopaedics will also link all the members of SICOT by means of an insert that will be concerned with SICOT matters. Finally, it is expected that news and information regarding all aspects of orthopaedic surgery, including meetings, panels, instructional courses, etc. will be brought to the attention of the readers. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been approved by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted. Reports of animal experiments must state that the "Principles of laboratory animal care" (NIH publication No. 85-23, revised 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable. The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfil the above-mentioned requirements.
期刊最新文献
Risk of Ossification of the Posterior Longitudinal Ligament (OPLL) following gout diagnosis: a nationwide cohort study. The diabetic shoulder: association between diabetes mellitus and adhesive capsulitis - a systematic review and meta-analysis. Alban Köhler, the pioneer of osteoradiology. Comment on "Efficacy analysis of small-incision in situ decompression under ultrasound combined with shear-wave elastography in the treatment of ulnar neuropathy at the elbow". Letter to the Editor on "Gamma 3 vs Gamma 3 RC in Unstable Extracapsular Hip Fractures: a prospective randomized study".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1