Dynamic Contrast-enhanced MRI Processing Comparison for Distinguishing True Progression From Pseudoprogression in High-grade Glioma.

IF 1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Computer Assisted Tomography Pub Date : 2025-01-27 DOI:10.1097/RCT.0000000000001716
Ahmad Amer, Shehbaz Ansari, Apollo Krayyem, Suprateek Kundu, Swapnil Khose, Halyna Pokhylevych, Susana Calle, Chirag B Patel, Zixi Yang, Ho-Ling Anthony Liu, Jason M Johnson
{"title":"Dynamic Contrast-enhanced MRI Processing Comparison for Distinguishing True Progression From Pseudoprogression in High-grade Glioma.","authors":"Ahmad Amer, Shehbaz Ansari, Apollo Krayyem, Suprateek Kundu, Swapnil Khose, Halyna Pokhylevych, Susana Calle, Chirag B Patel, Zixi Yang, Ho-Ling Anthony Liu, Jason M Johnson","doi":"10.1097/RCT.0000000000001716","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Treatment-related changes may occur due to radiation and temozolomide in glioblastoma and can mimic tumor progression on conventional MRI. DCE-MRI enables quantification of the extent of blood-brain barrier (BBB) disruption, providing information about areas of suspicious postcontrast T1 enhancement. We compared DCE-MRI processing methods for distinguishing true disease progression from pseudoprogression in high-grade gliomas (HGGs).</p><p><strong>Methods: </strong>We identified 110 patients with HGG treated with surgery and chemoradiation who underwent DCE-MRI to further interrogate areas of new/increasing enhancement. All patients had confirmatory surgery/biopsy with pathology-confirmed progression or pseudoprogression. Scans were performed at 3T and analyzed using nordicICE. The MCA, SSS, and Parker models are three standardized processing methodologies used to create ktrans maps, a parameter that quantifies BBB permeability. Three equal regions of interest were placed at sites of peak contrast enhancement within each lesion. Data from each method was processed for mean and maximum ktrans. We conducted several rounds of analysis and finalized a strategy on penalized support vector machines based on engineered features with bootstrap sampling.</p><p><strong>Results: </strong>The Parker method was significant for ktrans maximum in the combined pathology and clinical as well as the pathology-only data sets. MCA and SSS did not perform well under the SVM classifier for pathology only. For clinical follow-up subjects, the Parker method yielded statistically significant results for maximum and mean ktrans.</p><p><strong>Conclusions: </strong>The Parker method was effective in distinguishing PD and PsP for pathology and clinical data sets. MCA and SSS techniques were effective for the clinical data set.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001716","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Treatment-related changes may occur due to radiation and temozolomide in glioblastoma and can mimic tumor progression on conventional MRI. DCE-MRI enables quantification of the extent of blood-brain barrier (BBB) disruption, providing information about areas of suspicious postcontrast T1 enhancement. We compared DCE-MRI processing methods for distinguishing true disease progression from pseudoprogression in high-grade gliomas (HGGs).

Methods: We identified 110 patients with HGG treated with surgery and chemoradiation who underwent DCE-MRI to further interrogate areas of new/increasing enhancement. All patients had confirmatory surgery/biopsy with pathology-confirmed progression or pseudoprogression. Scans were performed at 3T and analyzed using nordicICE. The MCA, SSS, and Parker models are three standardized processing methodologies used to create ktrans maps, a parameter that quantifies BBB permeability. Three equal regions of interest were placed at sites of peak contrast enhancement within each lesion. Data from each method was processed for mean and maximum ktrans. We conducted several rounds of analysis and finalized a strategy on penalized support vector machines based on engineered features with bootstrap sampling.

Results: The Parker method was significant for ktrans maximum in the combined pathology and clinical as well as the pathology-only data sets. MCA and SSS did not perform well under the SVM classifier for pathology only. For clinical follow-up subjects, the Parker method yielded statistically significant results for maximum and mean ktrans.

Conclusions: The Parker method was effective in distinguishing PD and PsP for pathology and clinical data sets. MCA and SSS techniques were effective for the clinical data set.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
230
审稿时长
4-8 weeks
期刊介绍: The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).
期刊最新文献
Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT. A Prototype "Smart" 3-Dimensionally Printed Model Showcasing Interactivity: Implementing Voice Command for the Ventricular and Cisternal Systems. Assessment of a New CT Detector and Filtration Technology: Part 1 - X-ray Beam Characterization and Radiation Dosimetry. Assessment of a New CT Detector and Filtration Technology: Part 2-Image Quality in Phantoms, Cadavers, and Patients. Triangular Margin: Reliable Imaging Feature of Fibrous Dysplasia in Long Bones?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1