Validation of a Deep Learning Tool for Detection of Incidental Vertebral Compression Fractures.

IF 1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Computer Assisted Tomography Pub Date : 2025-01-27 DOI:10.1097/RCT.0000000000001726
Michelle Dai, Bryan-Clement Tiu, Jacob Schlossman, Angela Ayobi, Charlotte Castineira, Julie Kiewsky, Christophe Avare, Yasmina Chaibi, Peter Chang, Daniel Chow, Jennifer E Soun
{"title":"Validation of a Deep Learning Tool for Detection of Incidental Vertebral Compression Fractures.","authors":"Michelle Dai, Bryan-Clement Tiu, Jacob Schlossman, Angela Ayobi, Charlotte Castineira, Julie Kiewsky, Christophe Avare, Yasmina Chaibi, Peter Chang, Daniel Chow, Jennifer E Soun","doi":"10.1097/RCT.0000000000001726","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study evaluated the performance of a deep learning-based vertebral compression fracture (VCF) detection tool in patients with incidental VCF. The purpose of this study was to validate this tool across multiple sites and multiple vendors.</p><p><strong>Methods: </strong>This was a retrospective, multicenter, multinational blinded study using anonymized chest and abdominal CT scans performed for indications other than VCF in patients ≥50 years old. Images were obtained from 2 teleradiology companies in France and United States and were processed by CINA-VCF v1.0, a deep learning algorithm designed for VCF detection. Ground truth was established by majority consensus across 3 board-certified radiologists. Overall performance of CINA-VCF was evaluated, as well as subset analyses based on imaging acquisition parameters, baseline patient characteristics, and VCF severity. A subgroup was also analyzed and compared with available clinical radiology reports.</p><p><strong>Results: </strong>Four hundred seventy-four CT scans were included in this study, comprising 166 (35.0%) positive and 308 (65.0%) negative VCF cases. CINA-VCF demonstrated an area under the curve (AUC) of 0.97 (95% CI: 0.96-0.99), accuracy of 93.7% (95% CI: 91.1%-95.7%), sensitivity of 95.2% (95% CI: 90.7%-97.9%), and specificity of 92.9% (95% CI: 89.4%-96.5%). Subset analysis based on VCF severity resulted in a specificity of 94.2% (95% CI: 90.9%-96.6%) for grade 0 negative cases and a specificity of 64.3% (95% CI: 35.1%-87.2%) for grade 1 negative cases. For grades 2 and 3 positive cases, sensitivity was 89.7% (95% CI: 79.9%-95.8%) and 99.0% (95% CI: 94.4%-100.0%), respectively.</p><p><strong>Conclusions: </strong>CINA-VCF successfully detected incidental VCF and even outperformed clinical reports. The performance was consistent among all subgroups analyzed. Limitations of the tool included various confounding pathologies such as Schmorl's nodes and borderline cases. Despite these limitations, this study validates the applicability and generalizability of the tool in the clinical setting.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001726","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study evaluated the performance of a deep learning-based vertebral compression fracture (VCF) detection tool in patients with incidental VCF. The purpose of this study was to validate this tool across multiple sites and multiple vendors.

Methods: This was a retrospective, multicenter, multinational blinded study using anonymized chest and abdominal CT scans performed for indications other than VCF in patients ≥50 years old. Images were obtained from 2 teleradiology companies in France and United States and were processed by CINA-VCF v1.0, a deep learning algorithm designed for VCF detection. Ground truth was established by majority consensus across 3 board-certified radiologists. Overall performance of CINA-VCF was evaluated, as well as subset analyses based on imaging acquisition parameters, baseline patient characteristics, and VCF severity. A subgroup was also analyzed and compared with available clinical radiology reports.

Results: Four hundred seventy-four CT scans were included in this study, comprising 166 (35.0%) positive and 308 (65.0%) negative VCF cases. CINA-VCF demonstrated an area under the curve (AUC) of 0.97 (95% CI: 0.96-0.99), accuracy of 93.7% (95% CI: 91.1%-95.7%), sensitivity of 95.2% (95% CI: 90.7%-97.9%), and specificity of 92.9% (95% CI: 89.4%-96.5%). Subset analysis based on VCF severity resulted in a specificity of 94.2% (95% CI: 90.9%-96.6%) for grade 0 negative cases and a specificity of 64.3% (95% CI: 35.1%-87.2%) for grade 1 negative cases. For grades 2 and 3 positive cases, sensitivity was 89.7% (95% CI: 79.9%-95.8%) and 99.0% (95% CI: 94.4%-100.0%), respectively.

Conclusions: CINA-VCF successfully detected incidental VCF and even outperformed clinical reports. The performance was consistent among all subgroups analyzed. Limitations of the tool included various confounding pathologies such as Schmorl's nodes and borderline cases. Despite these limitations, this study validates the applicability and generalizability of the tool in the clinical setting.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
230
审稿时长
4-8 weeks
期刊介绍: The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).
期刊最新文献
Comparison of Radiation Dose and Image Quality in Pediatric Abdominopelvic Photon-Counting Versus Energy-Integrating Detector CT. A Prototype "Smart" 3-Dimensionally Printed Model Showcasing Interactivity: Implementing Voice Command for the Ventricular and Cisternal Systems. Assessment of a New CT Detector and Filtration Technology: Part 1 - X-ray Beam Characterization and Radiation Dosimetry. Assessment of a New CT Detector and Filtration Technology: Part 2-Image Quality in Phantoms, Cadavers, and Patients. Triangular Margin: Reliable Imaging Feature of Fibrous Dysplasia in Long Bones?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1