Tie Zhou, Yan Zhou, Lin Zhao, Yanmin Kan, Jianmin Ding, Cheng Sun, Xiang Jing
{"title":"Value of Spleen Dynamic Contrast-enhanced Ultrasound Parameters in Predicting Hepatic Vein Pressure Gradient for Patients With Liver Cirrhosis.","authors":"Tie Zhou, Yan Zhou, Lin Zhao, Yanmin Kan, Jianmin Ding, Cheng Sun, Xiang Jing","doi":"10.1097/MCG.0000000000002136","DOIUrl":null,"url":null,"abstract":"<p><strong>Goals: </strong>To explore dynamic contrast-enhanced ultrasound (CEUS) parameters in predicting hepatic vein pressure gradient (HVPG) for patients with liver cirrhosis (LC).</p><p><strong>Background: </strong>Noninvasive diagnosis of HVPG remains a challenge.</p><p><strong>Study: </strong>This prospective study included patients with LC undergoing hepatic vein catheterization and pressure measurement at the hospital from May 2021 to January 2023. The CEUS images (Mindray Resona R9, 1-6-MHz probe frequency; mechanical index=0.08; image depth=10 cm; focus at the lowest point of the diaphragm; dynamic range=70 dB; optimal gain; single SonoVue bolus injection) were taken for 60 seconds after injection and analyzed using VueBox. HVPG (ie, the gold standard for portal hypertension) was measured routinely by catheterization.</p><p><strong>Results: </strong>Fifty patients with LC were included in the study. The rise time (r=0.6, P<0.01), the fall time (r=0.7, P<0.01), the peak time (r=0.6, P<0.01), wash-in area under the curve (AUC) (r=0.5, P<0.01), the wash-out phase AUC (r=0.4, P<0.01) and wash-in and wash-out phase AUC (r=0.4, P<0.01) of the dynamic spleen CEUS were positively correlated with HVPG. The optimal fall time cutoff levels to predict HVPG ≥10 mm Hg and ≥12 mm Hg were 27.0 and 36.4 seconds, with the AUC being 0.958 and 0.941, respectively. The optimal area under the wash-in area cutoff level to predict HVPG ≥10 mm Hg and ≥12 mm Hg was 1,658,967.38 (a.u) and 4,244,015.90 (a.u), with the AUC being 0.865 and 0.877, respectively.</p><p><strong>Conclusions: </strong>The fall time and wash-in AUC obtained by dynamic CEUS may help diagnose HVPG in patients with LC without requiring invasive hepatic vein catheterization.</p>","PeriodicalId":15457,"journal":{"name":"Journal of clinical gastroenterology","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MCG.0000000000002136","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Goals: To explore dynamic contrast-enhanced ultrasound (CEUS) parameters in predicting hepatic vein pressure gradient (HVPG) for patients with liver cirrhosis (LC).
Background: Noninvasive diagnosis of HVPG remains a challenge.
Study: This prospective study included patients with LC undergoing hepatic vein catheterization and pressure measurement at the hospital from May 2021 to January 2023. The CEUS images (Mindray Resona R9, 1-6-MHz probe frequency; mechanical index=0.08; image depth=10 cm; focus at the lowest point of the diaphragm; dynamic range=70 dB; optimal gain; single SonoVue bolus injection) were taken for 60 seconds after injection and analyzed using VueBox. HVPG (ie, the gold standard for portal hypertension) was measured routinely by catheterization.
Results: Fifty patients with LC were included in the study. The rise time (r=0.6, P<0.01), the fall time (r=0.7, P<0.01), the peak time (r=0.6, P<0.01), wash-in area under the curve (AUC) (r=0.5, P<0.01), the wash-out phase AUC (r=0.4, P<0.01) and wash-in and wash-out phase AUC (r=0.4, P<0.01) of the dynamic spleen CEUS were positively correlated with HVPG. The optimal fall time cutoff levels to predict HVPG ≥10 mm Hg and ≥12 mm Hg were 27.0 and 36.4 seconds, with the AUC being 0.958 and 0.941, respectively. The optimal area under the wash-in area cutoff level to predict HVPG ≥10 mm Hg and ≥12 mm Hg was 1,658,967.38 (a.u) and 4,244,015.90 (a.u), with the AUC being 0.865 and 0.877, respectively.
Conclusions: The fall time and wash-in AUC obtained by dynamic CEUS may help diagnose HVPG in patients with LC without requiring invasive hepatic vein catheterization.
期刊介绍:
Journal of Clinical Gastroenterology gathers the world''s latest, most relevant clinical studies and reviews, case reports, and technical expertise in a single source. Regular features include cutting-edge, peer-reviewed articles and clinical reviews that put the latest research and development into the context of your practice. Also included are biographies, focused organ reviews, practice management, and therapeutic recommendations.