Brian A Francis, Vanessa Vera, Joshua Kim, Mahdi M Basha, Bryant Lum, Douglas Grayson, Steven Vold, Mini Balaram, Susan Simonyi, Husam Ansari, Natasha Nayak Kolomeyer
{"title":"One-Year Real-World Outcomes of Ab-Externo Gel Stent Placement From the EXPAND Study.","authors":"Brian A Francis, Vanessa Vera, Joshua Kim, Mahdi M Basha, Bryant Lum, Douglas Grayson, Steven Vold, Mini Balaram, Susan Simonyi, Husam Ansari, Natasha Nayak Kolomeyer","doi":"10.1097/IJG.0000000000002543","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).</p><p><strong>Purpose: </strong>To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.</p><p><strong>Methods: </strong>Multicenter, real-world, retrospective study. Consecutive adults with glaucoma and ab-externo GS implantation (with/without phacoemulsification or open/closed conjunctiva) ≥12 months before study entry. Data were extracted between the baseline/preoperative and last follow-up visit or date of secondary surgical intervention (SSI). Primary effectiveness endpoint: proportion of primary eyes (first eye in bilaterally implanted patients) at Month 12 (M12) achieving ≥20% intraocular pressure (IOP) reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or SSI. Secondary effectiveness endpoints included complete success (IOP ≤18 mmHg and ≥20% IOP reduction from medicated baseline without medication, clinical hypotony, or SSI); qualified success (same but without medication increase); and needling rate. Key safety endpoints (all eyes): intraoperative complications, postoperative adverse events (AEs), and SSIs.</p><p><strong>Results: </strong>The safety population included 466 eyes; 80.7% received the GS alone and 85.0% were implanted with closed conjunctiva. At M12, 39.1% of all primary eyes (N=413) and 54.9% of primary eyes with IOP and medication data at baseline and M12 (N=213) achieved the primary endpoint. At M12 among all primary eyes, the complete success, qualified success, and needling rates were 33.5%, 56.5%, and 28.6%. Most eyes (97.9%) had no intraoperative complications. The most frequent postoperative AE was transient/self-resolving hypotony (IOP<6 mmHg; 28.1%). Sixty-nine (14.8%) eyes required an SSI.</p><p><strong>Conclusions: </strong>Ab-externo GS placement effectively lowered IOP and the medication count without unexpected complications/AEs, expanding implantation options based on patients' needs and surgeons' preferences.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002543","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).
Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.
Methods: Multicenter, real-world, retrospective study. Consecutive adults with glaucoma and ab-externo GS implantation (with/without phacoemulsification or open/closed conjunctiva) ≥12 months before study entry. Data were extracted between the baseline/preoperative and last follow-up visit or date of secondary surgical intervention (SSI). Primary effectiveness endpoint: proportion of primary eyes (first eye in bilaterally implanted patients) at Month 12 (M12) achieving ≥20% intraocular pressure (IOP) reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or SSI. Secondary effectiveness endpoints included complete success (IOP ≤18 mmHg and ≥20% IOP reduction from medicated baseline without medication, clinical hypotony, or SSI); qualified success (same but without medication increase); and needling rate. Key safety endpoints (all eyes): intraoperative complications, postoperative adverse events (AEs), and SSIs.
Results: The safety population included 466 eyes; 80.7% received the GS alone and 85.0% were implanted with closed conjunctiva. At M12, 39.1% of all primary eyes (N=413) and 54.9% of primary eyes with IOP and medication data at baseline and M12 (N=213) achieved the primary endpoint. At M12 among all primary eyes, the complete success, qualified success, and needling rates were 33.5%, 56.5%, and 28.6%. Most eyes (97.9%) had no intraoperative complications. The most frequent postoperative AE was transient/self-resolving hypotony (IOP<6 mmHg; 28.1%). Sixty-nine (14.8%) eyes required an SSI.
Conclusions: Ab-externo GS placement effectively lowered IOP and the medication count without unexpected complications/AEs, expanding implantation options based on patients' needs and surgeons' preferences.
期刊介绍:
The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.