{"title":"Normothermic Machine Perfusion vs. Static Cold Storage in Liver Transplantation: A Systematic Review and Meta-Analysis.","authors":"Patricia Viana, Samy Castillo-Flores, Maria M R Mora, Thamiris D D Cabral, Paulo N Martins, Michael Kueht, Isabella Faria","doi":"10.1111/aor.14960","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Normothermic machine perfusion (NMP) represents an alternative to prolong liver preservation and reduce organ discard rates. We performed an updated systematic review and meta-analysis to compare NMP with static cold storage (SCS) in liver transplantation.</p><p><strong>Methods: </strong>MEDLINE, Embase, and Cochrane were searched for randomized controlled trials (RCTs) or observational studies. Risk ratios (RR) and mean differences were calculated. p < 0.05 was considered significant. A random-effects model was applied for all outcomes.</p><p><strong>Prospero id: </strong>CRD42023486184.</p><p><strong>Results: </strong>We included 1295 patients from 5 RCTs and 6 observational studies from 2016 to 2023. 592 (45.7%) underwent NMP. A subgroup RCT analysis favored NMP for non-anastomotic strictures (RR 0.4; 95% CI 0.2, 0.9), postreperfusion syndrome (RR 0.4; 95% CI 0.27, 0.56), and early allograft dysfunction (RR 0.6; 95% CI 0.4, 0.9). NMP favored higher organ utilization rates (RR 1.1; 95% CI 1.02, 1.18). No significant differences between NMP and SCS were observed in graft survival or patient survival at 12 months, primary non-function, serious adverse events, overall biliary complications, AST, or bilirubin levels peak within the first 7 days, ICU or hospital length of stay.</p><p><strong>Conclusion: </strong>Our findings suggest that NMP is associated with lower non-anastomotic biliary stricture rates, postreperfusion syndrome, early allograft dysfunction, and higher organ utilization in the RCT subgroup analysis, without increasing adverse events.</p>","PeriodicalId":8450,"journal":{"name":"Artificial organs","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/aor.14960","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Normothermic machine perfusion (NMP) represents an alternative to prolong liver preservation and reduce organ discard rates. We performed an updated systematic review and meta-analysis to compare NMP with static cold storage (SCS) in liver transplantation.
Methods: MEDLINE, Embase, and Cochrane were searched for randomized controlled trials (RCTs) or observational studies. Risk ratios (RR) and mean differences were calculated. p < 0.05 was considered significant. A random-effects model was applied for all outcomes.
Prospero id: CRD42023486184.
Results: We included 1295 patients from 5 RCTs and 6 observational studies from 2016 to 2023. 592 (45.7%) underwent NMP. A subgroup RCT analysis favored NMP for non-anastomotic strictures (RR 0.4; 95% CI 0.2, 0.9), postreperfusion syndrome (RR 0.4; 95% CI 0.27, 0.56), and early allograft dysfunction (RR 0.6; 95% CI 0.4, 0.9). NMP favored higher organ utilization rates (RR 1.1; 95% CI 1.02, 1.18). No significant differences between NMP and SCS were observed in graft survival or patient survival at 12 months, primary non-function, serious adverse events, overall biliary complications, AST, or bilirubin levels peak within the first 7 days, ICU or hospital length of stay.
Conclusion: Our findings suggest that NMP is associated with lower non-anastomotic biliary stricture rates, postreperfusion syndrome, early allograft dysfunction, and higher organ utilization in the RCT subgroup analysis, without increasing adverse events.
期刊介绍:
Artificial Organs is the official peer reviewed journal of The International Federation for Artificial Organs (Members of the Federation are: The American Society for Artificial Internal Organs, The European Society for Artificial Organs, and The Japanese Society for Artificial Organs), The International Faculty for Artificial Organs, the International Society for Rotary Blood Pumps, The International Society for Pediatric Mechanical Cardiopulmonary Support, and the Vienna International Workshop on Functional Electrical Stimulation. Artificial Organs publishes original research articles dealing with developments in artificial organs applications and treatment modalities and their clinical applications worldwide. Membership in the Societies listed above is not a prerequisite for publication. Articles are published without charge to the author except for color figures and excess page charges as noted.