Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2025-01-31 DOI:10.1186/s40729-025-00596-9
Kazuya Doi, Kaien Wakamatsu, Reiko Kobatake, Yoshifumi Oki, Yusuke Makihara, Masaru Konishi, Kazuhiro Tsuga
{"title":"Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs.","authors":"Kazuya Doi, Kaien Wakamatsu, Reiko Kobatake, Yoshifumi Oki, Yusuke Makihara, Masaru Konishi, Kazuhiro Tsuga","doi":"10.1186/s40729-025-00596-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The study aimed to examine the usefulness of a novel density measurement drill for evaluating cancellous bone density by examining the correlation between computed tomography (CT)-based Misch bone density classification and drilling torque value.</p><p><strong>Methods: </strong>Bovine ribs were used as the drilling sites for implant placement. Multidetector CT (MDCT) was performed after contrast materials were attached to the drilling sites. CT value within the region of interest (ROI) on MDCT scan was measured and classified according to the Misch classification (D1 to D5). Drilling torque value was measured using a novel measurement drill. Next, histomorphometric analysis of the drilling site was performed to assess bone density, expressed as percentage of bone area within ROI.</p><p><strong>Results: </strong>MDCT showed the presence of D2 (n = 87), D3 (n = 92), D4 (n = 133), and D5 (n = 52) at the measurement sites, however, no sites were classified as D1. The drilling torque values were 11.2 ± 3.2 Ncm for D2, 7.8 ± 3.3 Ncm for D3, and 3.0 ± 1.2 Ncm for D4, and 1.4 ± 0.6 Ncm for D5, with significant differences. A positive correlation was observed between CT value and drilling torque value (r = 0.99). Histomorphometric analysis revealed a positive correlation between drilling torque value and bone area ratio (r = 0.97).</p><p><strong>Conclusions: </strong>The results of this limited study demonstrated the usefulness of the direct and objective cancellous bone density evaluation method using a novel measurement drill. This evaluation method will be informative for subsequent treatment decisions.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"11 1","pages":"7"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11785876/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-025-00596-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The study aimed to examine the usefulness of a novel density measurement drill for evaluating cancellous bone density by examining the correlation between computed tomography (CT)-based Misch bone density classification and drilling torque value.

Methods: Bovine ribs were used as the drilling sites for implant placement. Multidetector CT (MDCT) was performed after contrast materials were attached to the drilling sites. CT value within the region of interest (ROI) on MDCT scan was measured and classified according to the Misch classification (D1 to D5). Drilling torque value was measured using a novel measurement drill. Next, histomorphometric analysis of the drilling site was performed to assess bone density, expressed as percentage of bone area within ROI.

Results: MDCT showed the presence of D2 (n = 87), D3 (n = 92), D4 (n = 133), and D5 (n = 52) at the measurement sites, however, no sites were classified as D1. The drilling torque values were 11.2 ± 3.2 Ncm for D2, 7.8 ± 3.3 Ncm for D3, and 3.0 ± 1.2 Ncm for D4, and 1.4 ± 0.6 Ncm for D5, with significant differences. A positive correlation was observed between CT value and drilling torque value (r = 0.99). Histomorphometric analysis revealed a positive correlation between drilling torque value and bone area ratio (r = 0.97).

Conclusions: The results of this limited study demonstrated the usefulness of the direct and objective cancellous bone density evaluation method using a novel measurement drill. This evaluation method will be informative for subsequent treatment decisions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs. Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial. Prediction models for the complication incidence and survival rate of dental implants-a systematic review and critical appraisal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1