Comparison of water exchange measurements between filter-exchange imaging and diffusion time-dependent kurtosis imaging in the human brain.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance in Medicine Pub Date : 2025-01-29 DOI:10.1002/mrm.30454
Zhaoqing Li, Chunjing Liang, Qingping He, Thorsten Feiweier, Yi-Cheng Hsu, Jianhua Li, Ruiliang Bai
{"title":"Comparison of water exchange measurements between filter-exchange imaging and diffusion time-dependent kurtosis imaging in the human brain.","authors":"Zhaoqing Li, Chunjing Liang, Qingping He, Thorsten Feiweier, Yi-Cheng Hsu, Jianhua Li, Ruiliang Bai","doi":"10.1002/mrm.30454","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Filter-exchange imaging (FEXI) and diffusion time (t)-dependent kurtosis imaging (DKI(t)) are two diffusion-based methods that have been proposed for in vivo measurements of water exchange rates. Few studies have directly compared these methods. We aimed to investigate whether FEXI and DKI(t) yield comparable water exchange measurements in the human brain in vivo.</p><p><strong>Methods: </strong>Eight healthy volunteers underwent multiple-direction FEXI and DKI(t) acquisitions on a 3T scanner. We performed region of interest (ROI) analysis to determine correlations between FEXI-derived apparent exchange rate (AXR) and DKI(t)-derived reciprocal of exchange time ( <math> <semantics><mrow><mn>1</mn> <mo>/</mo> <msub><mi>τ</mi> <mi>ex</mi></msub> </mrow> <annotation>$$ 1/{\\tau}_{ex} $$</annotation></semantics> </math> ).</p><p><strong>Results: </strong>In both white matter (WM) and gray matter (GM), DKI(t) revealed substantial diffusion-time dependence of diffusivity and kurtosis. However, at t ≥ 100 ms, the diffusivity showed weak time dependence. In WM, this time dependence may be due to water exchange between myelin water and \"free\" water with different T<sub>1</sub> values, although other factors, such as remaining restrictive effects from microstructural barriers, cannot be excluded. We found a significant correlation between DKI(t)-derived <math> <semantics><mrow><mn>1</mn> <mo>/</mo> <msub><mi>τ</mi> <mi>ex</mi></msub> </mrow> <annotation>$$ 1/{\\tau}_{ex} $$</annotation></semantics> </math> and FEXI-derived AXR in the axial direction within WM. No such correlation was present in GM, although both values showed similar ranges.</p><p><strong>Conclusion: </strong>These results suggest that FEXI and DKI(t) could be sensitive to the same water exchange process only when the diffusion time in DKI(t) is sufficiently long, and only in WM. In both GM and WM, the restrictive effect of microstructure is non-negligible, especially at short diffusion times (<100 ms).</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30454","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Filter-exchange imaging (FEXI) and diffusion time (t)-dependent kurtosis imaging (DKI(t)) are two diffusion-based methods that have been proposed for in vivo measurements of water exchange rates. Few studies have directly compared these methods. We aimed to investigate whether FEXI and DKI(t) yield comparable water exchange measurements in the human brain in vivo.

Methods: Eight healthy volunteers underwent multiple-direction FEXI and DKI(t) acquisitions on a 3T scanner. We performed region of interest (ROI) analysis to determine correlations between FEXI-derived apparent exchange rate (AXR) and DKI(t)-derived reciprocal of exchange time ( 1 / τ ex $$ 1/{\tau}_{ex} $$ ).

Results: In both white matter (WM) and gray matter (GM), DKI(t) revealed substantial diffusion-time dependence of diffusivity and kurtosis. However, at t ≥ 100 ms, the diffusivity showed weak time dependence. In WM, this time dependence may be due to water exchange between myelin water and "free" water with different T1 values, although other factors, such as remaining restrictive effects from microstructural barriers, cannot be excluded. We found a significant correlation between DKI(t)-derived 1 / τ ex $$ 1/{\tau}_{ex} $$ and FEXI-derived AXR in the axial direction within WM. No such correlation was present in GM, although both values showed similar ranges.

Conclusion: These results suggest that FEXI and DKI(t) could be sensitive to the same water exchange process only when the diffusion time in DKI(t) is sufficiently long, and only in WM. In both GM and WM, the restrictive effect of microstructure is non-negligible, especially at short diffusion times (<100 ms).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
期刊最新文献
Considerations and recommendations from the ISMRM diffusion study group for preclinical diffusion MRI: Part 1: In vivo small-animal imaging. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3-Ex vivo imaging: Data processing, comparisons with microscopy, and tractography. On the RF safety of titanium mesh head implants in 7 T MRI systems: an investigation. 3D joint T1/T1 ρ/T2 mapping and water-fat imaging for contrast-agent free myocardial tissue characterization at 1.5T. Whole liver phase-based R2 mapping in liver iron overload within a breath-hold.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1