Isochronal Apparent Dispersion at Early Activation Sites Accurately Identifies Outflow Tract Ventricular Ectopy Sites.

IF 2.2 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Heart, Lung and Circulation Pub Date : 2025-01-30 DOI:10.1016/j.hlc.2024.10.018
Robert D Anderson, Stephane Masse, Joshua Hawson, Geoffrey Lee, Mukund Prabhu, Abhishek Bhaskaran, Andrew C T Ha, Krishnakumar Nair, Vijay Chauhan, Kumaraswamy Nanthakumar
{"title":"Isochronal Apparent Dispersion at Early Activation Sites Accurately Identifies Outflow Tract Ventricular Ectopy Sites.","authors":"Robert D Anderson, Stephane Masse, Joshua Hawson, Geoffrey Lee, Mukund Prabhu, Abhishek Bhaskaran, Andrew C T Ha, Krishnakumar Nair, Vijay Chauhan, Kumaraswamy Nanthakumar","doi":"10.1016/j.hlc.2024.10.018","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Localisation of outflow tract (OT) premature ventricular complex (PVC) sites is guided by unipolar and bipolar local activation time (LAT). However, LAT-based localisation can be inaccurate if the site is intramural or distant. Deep foci produce rapid conduction velocity (CV) if the wavefront is tangential to the surface.</p><p><strong>Aim: </strong>We evaluated whether supraphysiological CV, referred to as surface isochronal apparent dispersion (IAD) mapping, can be used to accurately differentiate right and left ventricular OT PVC origin, guiding the successful site for OT PVC ablation.</p><p><strong>Method: </strong>Left ventricular OT mapping was performed if right ventricular OT mapping demonstrated a bipolar electrogram (EGM) <20 ms. The earliest EGMs underwent analysis of the following: first deflection bipolar EGM (bipolar<sub>earliest</sub>) to QRS, bipolar<sub>earliest</sub> to first deflection unipolar EGM (unipolar<sub>earliest</sub>), bipolar<sub>earliest</sub> to unipolar -dV/dT<sub>max</sub>, unipolar -dV/dT<sub>max</sub> to QRS, number of early LAT breakouts, and the surface area of the earliest isochronal breakout. Polynomial CV was calculated using a custom algorithm in MATLAB using cut-offs between 1 and 100,000 cm/s and used to create IAD, referred to as apparent dispersion index. The accuracy of IAD to distinguish between successful and unsuccessful OT sites was assessed and compared with conventional EGM indices.</p><p><strong>Results: </strong>Bipolar<sub>earliest</sub> to QRS (28.5±7.3 ms vs 17.8±5.7 ms; p<0.05) is superior to unipolar -dV/dt<sub>max</sub> to QRS (0.4±26.4 ms vs -6.4±13.4 ms; p=0.25) in differentiating successful and unsuccessful OT PVC sites. An early isochronal breakout area of less than 1 cm<sup>2</sup> and less than two breakouts indicates a successful side (both p<0.05). Bipolar<sub>earliest</sub> to unipolar -dV/dT<sub>max</sub> and to unipolar<sub>earliest</sub> were not predictive (28.1±27.7 vs 24.2±13.3 ms; p=0.97 and 6.4±7.3 vs 6.4±5.8 ms; p=0.8, respectively). IAD appears to differentiate between successful and unsuccessful sites using an apparent dispersion index cut-off of 20,000 cm/s, with an accuracy of 93.8% and area under the receiver operator characteristic of 0.95.</p><p><strong>Conclusions: </strong>IAD is a realistic two-dimensional interpretation of the three-dimensional activation mapping surface that may be associated with OT origins to guide a successful side of catheter ablation.</p>","PeriodicalId":13000,"journal":{"name":"Heart, Lung and Circulation","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart, Lung and Circulation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.hlc.2024.10.018","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Localisation of outflow tract (OT) premature ventricular complex (PVC) sites is guided by unipolar and bipolar local activation time (LAT). However, LAT-based localisation can be inaccurate if the site is intramural or distant. Deep foci produce rapid conduction velocity (CV) if the wavefront is tangential to the surface.

Aim: We evaluated whether supraphysiological CV, referred to as surface isochronal apparent dispersion (IAD) mapping, can be used to accurately differentiate right and left ventricular OT PVC origin, guiding the successful site for OT PVC ablation.

Method: Left ventricular OT mapping was performed if right ventricular OT mapping demonstrated a bipolar electrogram (EGM) <20 ms. The earliest EGMs underwent analysis of the following: first deflection bipolar EGM (bipolarearliest) to QRS, bipolarearliest to first deflection unipolar EGM (unipolarearliest), bipolarearliest to unipolar -dV/dTmax, unipolar -dV/dTmax to QRS, number of early LAT breakouts, and the surface area of the earliest isochronal breakout. Polynomial CV was calculated using a custom algorithm in MATLAB using cut-offs between 1 and 100,000 cm/s and used to create IAD, referred to as apparent dispersion index. The accuracy of IAD to distinguish between successful and unsuccessful OT sites was assessed and compared with conventional EGM indices.

Results: Bipolarearliest to QRS (28.5±7.3 ms vs 17.8±5.7 ms; p<0.05) is superior to unipolar -dV/dtmax to QRS (0.4±26.4 ms vs -6.4±13.4 ms; p=0.25) in differentiating successful and unsuccessful OT PVC sites. An early isochronal breakout area of less than 1 cm2 and less than two breakouts indicates a successful side (both p<0.05). Bipolarearliest to unipolar -dV/dTmax and to unipolarearliest were not predictive (28.1±27.7 vs 24.2±13.3 ms; p=0.97 and 6.4±7.3 vs 6.4±5.8 ms; p=0.8, respectively). IAD appears to differentiate between successful and unsuccessful sites using an apparent dispersion index cut-off of 20,000 cm/s, with an accuracy of 93.8% and area under the receiver operator characteristic of 0.95.

Conclusions: IAD is a realistic two-dimensional interpretation of the three-dimensional activation mapping surface that may be associated with OT origins to guide a successful side of catheter ablation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Heart, Lung and Circulation
Heart, Lung and Circulation CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.50
自引率
3.80%
发文量
912
审稿时长
11.9 weeks
期刊介绍: Heart, Lung and Circulation publishes articles integrating clinical and research activities in the fields of basic cardiovascular science, clinical cardiology and cardiac surgery, with a focus on emerging issues in cardiovascular disease. The journal promotes multidisciplinary dialogue between cardiologists, cardiothoracic surgeons, cardio-pulmonary physicians and cardiovascular scientists.
期刊最新文献
Isochronal Apparent Dispersion at Early Activation Sites Accurately Identifies Outflow Tract Ventricular Ectopy Sites. Elucidating the Causal Link Between Treg-Related Immune Traits and Atherosclerosis-Related Cardiovascular Diseases: A Bidirectional Mendelian Randomisation Analysis. Effectiveness of Various Sternal Closure Devices Post Adult Cardiac Surgery. The Clinical Significance of PCI-Related Myocardial Infarction in Stable Ischaemic Heart Disease Patients in the Era of hs-Troponin. Identifying Gaps in Detection of Heart Valve Disease in Australia: A Population Survey.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1