Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire

Tiago Miguel Orantos Borralho, João Paulo Correia Rodrigues, Cristina Calmeiro dos Santos
{"title":"Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire","authors":"Tiago Miguel Orantos Borralho,&nbsp;João Paulo Correia Rodrigues,&nbsp;Cristina Calmeiro dos Santos","doi":"10.1007/s44150-025-00127-5","DOIUrl":null,"url":null,"abstract":"<div><p>It is essential to ensure that any building has conditions for a safe evacuation of its occupants. This aspect is essential in subway stations, where evacuation has to be carried out in an upward way, and usually correspond to large structures constituting a single fire compartment. Baixa-Chiado subway station, in Lisbon, Portugal, was selected for studying the evacuation in case of fire, due to its depth, high number of passengers that frequent the station and the existing of two intersecting train lines. A calculation of evacuation time was calculated and the way of evacuation studied, in different fire scenarios, number and location of occupants. The numerical simulations used Fire Dynamics Simulator and Pathfinder softwares, the first for fire spreading and the second for evacuation analysis. The importance of smoke control system, and its rapid activation in case of fire, was highlighted by the results obtained. In situations where this did not occur, there was a significant worsening in the evacuation of the occupants. It was estimated the incapacitation of a significant number of occupants, considering the levels registered for the fractional effective dose. The station’s architectural constraints proved to be a crucial factor in the results of the study. This article highlights important results applicable to subway stations around the world.</p></div>","PeriodicalId":100117,"journal":{"name":"Architecture, Structures and Construction","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Architecture, Structures and Construction","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1007/s44150-025-00127-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It is essential to ensure that any building has conditions for a safe evacuation of its occupants. This aspect is essential in subway stations, where evacuation has to be carried out in an upward way, and usually correspond to large structures constituting a single fire compartment. Baixa-Chiado subway station, in Lisbon, Portugal, was selected for studying the evacuation in case of fire, due to its depth, high number of passengers that frequent the station and the existing of two intersecting train lines. A calculation of evacuation time was calculated and the way of evacuation studied, in different fire scenarios, number and location of occupants. The numerical simulations used Fire Dynamics Simulator and Pathfinder softwares, the first for fire spreading and the second for evacuation analysis. The importance of smoke control system, and its rapid activation in case of fire, was highlighted by the results obtained. In situations where this did not occur, there was a significant worsening in the evacuation of the occupants. It was estimated the incapacitation of a significant number of occupants, considering the levels registered for the fractional effective dose. The station’s architectural constraints proved to be a crucial factor in the results of the study. This article highlights important results applicable to subway stations around the world.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Criteria for enhancing comfort and liveability conditions in homogenous built contexts through innovative façade interventions Fire safety regulations in Brazil: Analysis of the occupancy classification of buildings Investigating the factors that define and influence safety culture: perspectives from expert professionals Designing for timber circularity: Potential challenges and approaches from the lens of two educational design/build projects Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1