Influence of Opening Size and Position on the Performance of Forced-Air Precooling of Apples

IF 2.9 3区 农林科学 Q3 ENGINEERING, CHEMICAL Journal of Food Process Engineering Pub Date : 2025-01-16 DOI:10.1111/jfpe.70024
Xiaozhuan Chen, Yunpeng Wang, Wei Sheng, Haikun Zheng, Maierzukejiang Bayizi, Shishun Pan, Sikai Liu, Dong Li
{"title":"Influence of Opening Size and Position on the Performance of Forced-Air Precooling of Apples","authors":"Xiaozhuan Chen,&nbsp;Yunpeng Wang,&nbsp;Wei Sheng,&nbsp;Haikun Zheng,&nbsp;Maierzukejiang Bayizi,&nbsp;Shishun Pan,&nbsp;Sikai Liu,&nbsp;Dong Li","doi":"10.1111/jfpe.70024","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>In this article, to investigate the comprehensive influence of the opening size and location of the packing box on precooling performance, a simulation model of precooling with 20 opening parameters is established based on computational fluid dynamics. There are six openings on one side of the box, 12 in total, with 5 opening positions (Cases 1–5) and 4 opening sizes, each with an opening size and corresponding total opening area of 15 mm (2120 mm<sup>2</sup>), 30 mm (8482 mm<sup>2</sup>), 45 mm (19,085 mm<sup>2</sup>), and 60 mm (33,929 mm<sup>2</sup>). The results show that when the diameter of the opening is 15–60 mm, increasing the opening increases the precooling time, and Case 4, which moves the position of the openings on both sides to the left and right, reduces the precooling time. Increasing the opening does not necessarily improve precooling uniformity at different opening positions. Case 5, with the position of the two side openings moved toward the center, had the worst precooling uniformity for each opening size. The larger the opening, the lower the precooling energy consumption for a given opening position. This is because the reduction in power at increased opening is much greater than the increase in precooling time. When the opening size is certain, the reasonable opening position can reduce the precooling energy consumption. Case 4, 30 mm is more balanced overall. Therefore, the opening parameter has a large impact on the precooling performance, and it is necessary to select the opening parameter reasonably for different requirements.</p>\n </div>","PeriodicalId":15932,"journal":{"name":"Journal of Food Process Engineering","volume":"48 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Process Engineering","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jfpe.70024","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this article, to investigate the comprehensive influence of the opening size and location of the packing box on precooling performance, a simulation model of precooling with 20 opening parameters is established based on computational fluid dynamics. There are six openings on one side of the box, 12 in total, with 5 opening positions (Cases 1–5) and 4 opening sizes, each with an opening size and corresponding total opening area of 15 mm (2120 mm2), 30 mm (8482 mm2), 45 mm (19,085 mm2), and 60 mm (33,929 mm2). The results show that when the diameter of the opening is 15–60 mm, increasing the opening increases the precooling time, and Case 4, which moves the position of the openings on both sides to the left and right, reduces the precooling time. Increasing the opening does not necessarily improve precooling uniformity at different opening positions. Case 5, with the position of the two side openings moved toward the center, had the worst precooling uniformity for each opening size. The larger the opening, the lower the precooling energy consumption for a given opening position. This is because the reduction in power at increased opening is much greater than the increase in precooling time. When the opening size is certain, the reasonable opening position can reduce the precooling energy consumption. Case 4, 30 mm is more balanced overall. Therefore, the opening parameter has a large impact on the precooling performance, and it is necessary to select the opening parameter reasonably for different requirements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开口尺寸和位置对苹果强制空气预冷性能的影响
为了研究填料箱开孔尺寸和位置对预冷性能的综合影响,建立了基于计算流体力学的含20个开孔参数的预冷仿真模型。箱体一侧有6个开口,共12个,有5个开口位置(例1-5)和4个开口尺寸,每个开口尺寸和对应的总开口面积分别为15mm (2120 mm2)、30mm (8482 mm2)、45mm (19085 mm2)和60mm (33929 mm2)。结果表明:当开孔直径为15 ~ 60mm时,增大开孔可延长预冷时间;在案例4中,将两侧开孔的位置向左和向右移动,可缩短预冷时间。增加开度并不一定改善不同开度位置的预冷均匀性。Case 5两侧开孔位置向中心移动时,各开孔尺寸预冷均匀性最差。开度越大,给定开度位置的预冷能耗越低。这是因为增大开度时功率的减少远远大于预冷时间的增加。在开孔尺寸一定的情况下,合理的开孔位置可以降低预冷能耗。情况4,30毫米是更平衡的整体。因此开度参数对预冷性能影响较大,有必要针对不同要求合理选择开度参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Food Process Engineering
Journal of Food Process Engineering 工程技术-工程:化工
CiteScore
5.70
自引率
10.00%
发文量
259
审稿时长
2 months
期刊介绍: This international research journal focuses on the engineering aspects of post-production handling, storage, processing, packaging, and distribution of food. Read by researchers, food and chemical engineers, and industry experts, this is the only international journal specifically devoted to the engineering aspects of food processing. Co-Editors M. Elena Castell-Perez and Rosana Moreira, both of Texas A&M University, welcome papers covering the best original research on applications of engineering principles and concepts to food and food processes.
期刊最新文献
Research on Real-Time Cooking of 3D-Printed Silver Carp Surimi Using CO2 Laser Research on Real-Time Cooking of 3D-Printed Silver Carp Surimi Using CO2 Laser Open Sun and Cabinet Drying of Whole Tamarind Fruit and Its Modeling Approach Open Sun and Cabinet Drying of Whole Tamarind Fruit and Its Modeling Approach Hesperidin Encapsulation for Food, Pharmaceutical, and Chemical Industries: A Bibliometric Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1