The Spectrum of Functional, Structural and Patient-Reported Outcomes in Intermediate Age-Related Macular Degeneration - A MACUSTAR Study Report.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY Ophthalmologica Pub Date : 2025-02-03 DOI:10.1159/000543231
Jan Henrik Terheyden, Frank G Holz, Charlotte Behning, Hannah M P Dunbar, Steffen Schmitz-Valckenberg, Adnan Tufail, Matthias Schmid, David P Crabb, Marlene Saßmannshausen, Alison Binns, Carel B Hoyng, Nadia Zakaria, Stephen Poor, Klaus-Peter Moll, Deborah Cosette, Cecília Martinho, Joana Batuca, José Cunha-Vaz, Ulrich F O Luhmann, Sergio Leal, Robert P Finger
{"title":"The Spectrum of Functional, Structural and Patient-Reported Outcomes in Intermediate Age-Related Macular Degeneration - A MACUSTAR Study Report.","authors":"Jan Henrik Terheyden, Frank G Holz, Charlotte Behning, Hannah M P Dunbar, Steffen Schmitz-Valckenberg, Adnan Tufail, Matthias Schmid, David P Crabb, Marlene Saßmannshausen, Alison Binns, Carel B Hoyng, Nadia Zakaria, Stephen Poor, Klaus-Peter Moll, Deborah Cosette, Cecília Martinho, Joana Batuca, José Cunha-Vaz, Ulrich F O Luhmann, Sergio Leal, Robert P Finger","doi":"10.1159/000543231","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>There is an unmet medical need for therapies in intermediate age-related macular degeneration (iAMD). The prospective European multi-center cohort study MACUSTAR validates structural, functional and patient-reported iAMD endpoints for use in future trials. The multiplicity of assessments allows characterizing iAMD in more dimensions than previously available. We describe the heterogeneity of assessments in the iAMD baseline cohort of the MACUSTAR study.</p><p><strong>Methods: </strong>A wide range of assessments were administered across 20 European study sites in accordance with established guidelines. These assessments encompassed multiple structural evaluations, such as color fundus photography, fundus autofluorescence, and optical coherence tomography. Additionally, functional tests were conducted, including assessments of best-corrected and low-luminance visual acuity (VA), Moorfields acuity, contrast sensitivity, reading speed, mesopic and scotopic microperimetry, and dark adaptometry. Moreover, patient-reported outcome assessments, specifically the Vision Impairment in Low Luminance questionnaire, were also incorporated into the evaluation process. Associations between variables were investigated using Phi coefficients, Pearson correlation coefficients and age-corrected regression models.</p><p><strong>Results: </strong>Five-hundred eighty-five individuals with iAMD (66% women; mean (standard deviation) age: 72±7 years) were included in the MACUSTAR study. Forty-nine percent had pigmentary abnormalities, 27% had reticular pseudodrusen; 10% and 9% had incomplete and complete retinal pigment epithelium and outer retinal atrophy at baseline, respectively. Mean best-corrected VA, low-luminance VA and mesopic average threshold on microperimetry at baseline were 0.03±0.11 logMAR, 0.24±0.16 logMAR and 23.3±3.7 dB. Mean VILL subscale scores at baseline were 2±2 to 2±3 logits. Phi coefficients between structural assessments ranged between 0.17 and 0.22 (median 0.21); correlation coefficients between function tests ranged between 0.07 and 0.69 (median 0.34) and between VILL scores ranged between 0.21 and 0.68 (median 0.23).</p><p><strong>Conclusion: </strong>The findings from this broad and comprehensive spectrum of assessments of structure, function, and patient-reported outcomes in iAMD suggest that the disease spectrum is diverse and heterogeneous and that further efforts are necessary to fully understand and characterize iAMD in all its complexities. A further in-depth characterization will enable novel enrichment strategies for clinical trials in iAMD.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov, NCT03349801. Registered on November 22, 2017.</p>","PeriodicalId":19595,"journal":{"name":"Ophthalmologica","volume":" ","pages":"1-19"},"PeriodicalIF":2.1000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000543231","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: There is an unmet medical need for therapies in intermediate age-related macular degeneration (iAMD). The prospective European multi-center cohort study MACUSTAR validates structural, functional and patient-reported iAMD endpoints for use in future trials. The multiplicity of assessments allows characterizing iAMD in more dimensions than previously available. We describe the heterogeneity of assessments in the iAMD baseline cohort of the MACUSTAR study.

Methods: A wide range of assessments were administered across 20 European study sites in accordance with established guidelines. These assessments encompassed multiple structural evaluations, such as color fundus photography, fundus autofluorescence, and optical coherence tomography. Additionally, functional tests were conducted, including assessments of best-corrected and low-luminance visual acuity (VA), Moorfields acuity, contrast sensitivity, reading speed, mesopic and scotopic microperimetry, and dark adaptometry. Moreover, patient-reported outcome assessments, specifically the Vision Impairment in Low Luminance questionnaire, were also incorporated into the evaluation process. Associations between variables were investigated using Phi coefficients, Pearson correlation coefficients and age-corrected regression models.

Results: Five-hundred eighty-five individuals with iAMD (66% women; mean (standard deviation) age: 72±7 years) were included in the MACUSTAR study. Forty-nine percent had pigmentary abnormalities, 27% had reticular pseudodrusen; 10% and 9% had incomplete and complete retinal pigment epithelium and outer retinal atrophy at baseline, respectively. Mean best-corrected VA, low-luminance VA and mesopic average threshold on microperimetry at baseline were 0.03±0.11 logMAR, 0.24±0.16 logMAR and 23.3±3.7 dB. Mean VILL subscale scores at baseline were 2±2 to 2±3 logits. Phi coefficients between structural assessments ranged between 0.17 and 0.22 (median 0.21); correlation coefficients between function tests ranged between 0.07 and 0.69 (median 0.34) and between VILL scores ranged between 0.21 and 0.68 (median 0.23).

Conclusion: The findings from this broad and comprehensive spectrum of assessments of structure, function, and patient-reported outcomes in iAMD suggest that the disease spectrum is diverse and heterogeneous and that further efforts are necessary to fully understand and characterize iAMD in all its complexities. A further in-depth characterization will enable novel enrichment strategies for clinical trials in iAMD.

Trial registration: ClinicalTrials.gov, NCT03349801. Registered on November 22, 2017.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Ophthalmologica
Ophthalmologica 医学-眼科学
CiteScore
5.10
自引率
3.80%
发文量
39
审稿时长
3 months
期刊介绍: Published since 1899, ''Ophthalmologica'' has become a frequently cited guide to international work in clinical and experimental ophthalmology. It contains a selection of patient-oriented contributions covering the etiology of eye diseases, diagnostic techniques, and advances in medical and surgical treatment. Straightforward, factual reporting provides both interesting and useful reading. In addition to original papers, ''Ophthalmologica'' features regularly timely reviews in an effort to keep the reader well informed and updated. The large international circulation of this journal reflects its importance.
期刊最新文献
The Spectrum of Functional, Structural and Patient-Reported Outcomes in Intermediate Age-Related Macular Degeneration - A MACUSTAR Study Report. Clinical Outcomes of the PAUL® Glaucoma Implant for secondary glaucoma after vitreoretinal surgery. Ultrasound Biomicroscopy in Scleral Fixation Using Gore-Tex Suture of a Subluxated Posterior Chamber Intraocular Lens. Concomitant Traumatic Macular Hole and Orbital Fracture. Silicone Oil Inhibits Early Bacterial Expansion in an in vitro Model of Intraocular Tamponade.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1