Late stent thrombosis six months after ultrathin-strut covered stent implantation in lesion with calcified nodule

Naoko Higashino MD, Takayuki Ishihara MD, Takuya Tsujimura MD, Yosuke Hata MD, Sho Nakao MD, Masaya Kusuda MD, Toshiaki Mano MD, PhD
{"title":"Late stent thrombosis six months after ultrathin-strut covered stent implantation in lesion with calcified nodule","authors":"Naoko Higashino MD,&nbsp;Takayuki Ishihara MD,&nbsp;Takuya Tsujimura MD,&nbsp;Yosuke Hata MD,&nbsp;Sho Nakao MD,&nbsp;Masaya Kusuda MD,&nbsp;Toshiaki Mano MD, PhD","doi":"10.1016/j.jccase.2024.11.002","DOIUrl":null,"url":null,"abstract":"<div><div>A 72-year-old woman undergoing hemodialysis presented with effort angina pectoris due to severe stenosis with calcified nodules in the right coronary artery. Percutaneous coronary intervention was performed using an excimer laser coronary angioplasty and an ultrathin-strut covered stent (CS) was implanted due to coronary perforation. An additional durable-polymer everolimus-eluting stent (DP-EES) was implanted because of protrusions in the proximal edge of the CS. However, late stent thrombosis occurred six months after ultrathin-strut covered stent implantation for a calcified nodule. After thrombus aspiration, intravascular imaging analyses revealed that the struts within the CS were fully covered with thick neointimal hyperplasia. In contrast, half of the struts in the DP-EES were uncovered and some struts were malapposed. In this case, we speculated that the cause of the current late stent thrombosis was dispersion of the thrombi formed at the uncovered with malapposed sites in the DP-EES into a severe stenosis caused by neointimal hyperplasia in the CS. Neointimal hyperplasia occurs at the edge of the CS, a CS should be implanted locating its edge on the site with less plaque.</div></div><div><h3>Learning objectives</h3><div><ul><li><span>•</span><span><div>To evaluate the mechanism of late stent thrombosis after ultrathin strut-covered stent implantation for lesions with calcified nodules.</div></span></li><li><span>•</span><span><div>To discuss the optimal covered stent placement locating its edge on the site with less plaque.</div></span></li><li><span>•</span><span><div>To recognize that introduction of an ultrathin-strut covered stent for lesions with calcified nodules requires careful consideration.</div></span></li></ul></div></div>","PeriodicalId":52092,"journal":{"name":"Journal of Cardiology Cases","volume":"31 2","pages":"Pages 46-48"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiology Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1878540924000987","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

A 72-year-old woman undergoing hemodialysis presented with effort angina pectoris due to severe stenosis with calcified nodules in the right coronary artery. Percutaneous coronary intervention was performed using an excimer laser coronary angioplasty and an ultrathin-strut covered stent (CS) was implanted due to coronary perforation. An additional durable-polymer everolimus-eluting stent (DP-EES) was implanted because of protrusions in the proximal edge of the CS. However, late stent thrombosis occurred six months after ultrathin-strut covered stent implantation for a calcified nodule. After thrombus aspiration, intravascular imaging analyses revealed that the struts within the CS were fully covered with thick neointimal hyperplasia. In contrast, half of the struts in the DP-EES were uncovered and some struts were malapposed. In this case, we speculated that the cause of the current late stent thrombosis was dispersion of the thrombi formed at the uncovered with malapposed sites in the DP-EES into a severe stenosis caused by neointimal hyperplasia in the CS. Neointimal hyperplasia occurs at the edge of the CS, a CS should be implanted locating its edge on the site with less plaque.

Learning objectives

  • To evaluate the mechanism of late stent thrombosis after ultrathin strut-covered stent implantation for lesions with calcified nodules.
  • To discuss the optimal covered stent placement locating its edge on the site with less plaque.
  • To recognize that introduction of an ultrathin-strut covered stent for lesions with calcified nodules requires careful consideration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Cardiology Cases
Journal of Cardiology Cases Medicine-Cardiology and Cardiovascular Medicine
CiteScore
0.90
自引率
0.00%
发文量
177
审稿时长
59 days
期刊最新文献
Rescue from sudden ventricular tachycardia and fibrillation using wearable cardioverter-defibrillator in male late-onset Fabry disease patient Pemafibrate and cardiac reverse remodeling in patients with systolic heart failure receiving guideline-directed medical therapy Advanced retrieval technique using pacemaker lead extraction methods for a long-term implanted inferior vena cava filter with caval penetration of the pancreas Effectiveness of surgery and chemotherapy with immune checkpoint inhibitor for cardiac metastatic squamous cell carcinoma of unknown primary Late stent thrombosis six months after ultrathin-strut covered stent implantation in lesion with calcified nodule
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1